Renal Artery Stenosis Clinical Trial
— ARTISANOfficial title:
ARTISAN: iCAST™ RX De Novo Stent Placement for the Treatment of Atherosclerotic Renal Artery Stenosis in Patients With Resistant Hypertension
Verified date | November 2020 |
Source | Atrium Medical Corporation |
Contact | n/a |
Is FDA regulated | No |
Health authority | |
Study type | Interventional |
The purpose of this trial is to test how well the iCAST™ RX Stent works in patients diagnosed with atherosclerotic renal artery stenosis and whether or not increased blood flow by the stent will help to control blood pressure.
Status | Completed |
Enrollment | 68 |
Est. completion date | October 26, 2020 |
Est. primary completion date | June 27, 2018 |
Accepts healthy volunteers | No |
Gender | All |
Age group | 18 Years and older |
Eligibility | General Inclusion Criteria: 1. Age = 18 at the time of informed consent. 2. Subject or subject's legal representative have been informed of the nature of the trial, agrees to participate, and has signed an Institutional Review Board (IRB)/Ethics Committee (EC) approved Informed Consent Form (ICF). 3. Subjects that have bilateral kidneys or a solitary functioning kidney with Renal Artery Stenosis in at least one kidney and an average Systolic Blood Pressure (SBP) = 155mmHg. 4. Subject has a history of maximum tolerable dose of = 3 anti-hypertensive medications of different classes, one of which must be a diuretic (for at least two weeks prior to Medical Documentation Screening period). a. A documented history for a minimum of 3 months showing reasonable and aggressive efforts to manage hypertension prior to consent. This must include the use of a broad variety of medications that have been used and failed or not tolerated. 5. Subject must have documented clinical evidence to support likelihood of angiographic findings > 80% whether it is DUS, CTa, MRa or other medical evidence. 6. New York Heart Association (NYHA) class I, II, or III the time of trial enrollment. Note: When a subject has bilateral Renal Artery Stenosis both of which require stenting, it is recommended to treat both kidneys with an iCAST™ RX Stent System during the index procedure. In the event that a subject needs a renal stenting procedure staged for renal protection, it is important that the Investigator treats the second renal artery with an iCAST™ RX Stent System after 30 days of the index procedure. If subjects with bilateral stenosis have only one lesion that meets protocol inclusion criteria that lesion should be treated per protocol. The recommendation is to NOT treat the second non-qualifying lesion, however if the operator feels strongly it is indicated, then they should treat per standard of care after 30-days post index procedure in order to comply with exclusion criteria #10. Subjects with flash pulmonary edema are allowed into the trial should they meet all other Inclusion and Exclusion criteria. Angiographic Anatomic Inclusion Criteria: 1. Angiographic diameter renal artery stenosis = 80% involving unilateral or bilateral renal arteries. a. The degree of percent diameter stenosis for all lesions intended to be treated, must be confirmed via one of the following methods: i. Manual or automated measurement with calipers ii. Measured Flow Fraction Reserve (FFR) < 0.8 using a pressure wire iii. Measured translesional peak pressure gradient of > 21 mmHg after induced hyperemia via dopamine or papaverine using a 4 Fr or less catheter or pressure wire. b. Subjects with 60-79% angiographic stenosis who have confirmed FFR < 0.8 may be enrolled. 2. Renal pole-to-pole length > 8cm (per visual estimate). 3. Target lesion length = 16mm per vessel (per visual estimate). 4. Renal artery vessel diameter = 5.0mm and = 7.0mm (per visual estimate). 5. Lesion originating = 15mm of the renal ostium. General Exclusion Criteria: 1. Subject's estimated life expectancy is < 12 months. 2. Subject has a history of transplanted kidney(s), has had another recent organ transplant or polycystic kidney disease. 3. Subject with estimated glomerular filtration rate (eGFR) = 25 mL/min/1.73 m2 4. Subject has a history of bleeding diathesis or coagulopathy or refuses blood transfusions. 5. Subject has a known contraindication to heparin, aspirin, thienopyridine, other anti-coagulant/antithrombotic therapies, contrast media, stainless steel, and/or polytetrafluoroethylene (PTFE). 6. Subject has had a previous renal bypass operation, a bypass is planned, or the target lesion is located within or beyond a bypass graft. 7. Subject has received a thrombolytic agent within the past 30 days. 8. Subject has documented acute pulmonary edema or systolic heart failure with ejection fraction < 30% and/or hospitalization requiring intubation and ventilation support for this diagnosis within the previous 90 days or hypertensive emergencies defined as resulting in organ damage. 9. Concurrent enrollment in any investigational trial wherein subject's participation has not been completed. 10. Subject has had a planned or anticipated cardiovascular surgical or interventional procedure outside of the affected renal artery (including, but not limited to, aortic, renal, cardiac, carotid, femoro-popliteal, and below the knee) within 30 days prior to the index procedure and prior to completion of the 30 day follow-up. 11. Subject has suffered a stroke or Transient Ischemic Attack (TIA) in the past 3 months. 12. Subject is pregnant, lactating, or is of child-bearing potential and plans to become pregnant during the follow-up trial period. 13. Subject with significant valvular disease. 14. Subject with known significant proteinuria > 2+ or > 2.0gm/d. 15. Subject with known bilateral upper-extremity arterial stenosis that result in spuriously low arm pressures or without the ability to gain reliable blood pressure measurements in at least one upper extremity. 16. Subject with active sepsis. 17. Subject with serum creatinine = 3.0mg/dL. 18. Subject with NYHA Class IV at the time of enrollment. 19. Subject is on hemodialysis. 20. Subject has a history of renal aneurysm. 21. Subject with cardiogenic shock. 22. Subject with cardiomyopathy. 23. Subject has an uncontrolled concurrent illness, including but not limited to ongoing or active infection or active autoimmune disease requiring immunosuppressive therapy. 24. Any subject with clinically significant cardiovascular, respiratory, neurologic, hepatic, endocrine, major systematic disease, making implementation or interpretation of the protocol or protocol results difficult or who in the opinion of the investigator would not be a good candidate for enrollment. Angiographic Anatomic Exclusion Criteria: 1. The planned site of intervention is totally occluded or has an anatomic configuration likely to prohibit adequate dilatation, and/or passage or implantation of the investigational device. 2. Subject has multiple ipsilateral lesions of the target renal artery that cannot be covered by a single stent. 3. There is a previously implanted stent in the target vessel or there is a previously implanted stent in the contralateral vessel < one year. 4. Subject has fibromuscular dysplasia, in renal artery and/or other vascular bed. 5. The target lesion site is associated with a thrombus. 6. Target lesion treated with laser atherectomy, directional atherectomy or other adjuncts to percutaneous balloon angioplasty (PTA). 7. Subject has a critical stenotic (> 70%) small accessory renal artery. 8. Subject has an abdominal aortic aneurysm > 4.0cm in diameter or a severe atherosclerotic aorta. 9. Main renal artery length = 15mm precluding the safe deployment of a covered renal stent. 10. Any lesion that would include blocking of renal artery side branch. 11. Renal artery stenosis due to dissection of renal artery: spontaneous or traumatic. |
Country | Name | City | State |
---|---|---|---|
United States | Massachusetts General Hospital | Boston | Massachusetts |
United States | Mid Carolina Cardiology | Charlotte | North Carolina |
United States | Clearwater Cardiovascular and Interventional Consultants | Clearwater | Florida |
United States | OhioHealth Research Institute | Columbus | Ohio |
United States | Mission Cardiovascular Research Institute | Fremont | California |
United States | Wellmont CVA Heart Institute | Kingsport | Tennessee |
United States | Tennova Healthcare - Turkey Creek Medical Center | Knoxville | Tennessee |
United States | Medical Center of the Rockies | Loveland | Colorado |
United States | Advocate Health and Hospitals Corporation | Naperville | Illinois |
United States | NC Heart and Vascular Research | Raleigh | North Carolina |
United States | Beaumont Health Systems | Royal Oak | Michigan |
United States | Holy Name Medical Center | Teaneck | New Jersey |
Lead Sponsor | Collaborator |
---|---|
Atrium Medical Corporation |
United States,
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | Primary Patency | Primary patency rate at 9 months was defined as continuous patency without the occurrence of a total occlusion of the original lesion, without a re-intervention to treat a partial or total occlusion of the stented segment, or bypass of the stented segment due to clinically-driven restenosis or occlusion. | 9 months | |
Primary | Systolic Blood Pressure | Change in systolic blood pressure (SBP) at 9 months as compared to baseline SBP. | Baseline and 9 months | |
Secondary | Procedure-Related Major Adverse Events (MAE) | The occurence of procedure-related MAEs is reported as a percentage of subjects with MAE. Inclusive of:
Procedure- or device-related occurrence of death Q-Wave myocardial infarction (MI) Clinically driven target lesion revascularization (TLR) Significant embolic events defined as unanticipated kidney/bowel infarct, clinically driven by symptoms of abdominal or back pain and confirmed with CT scan or open surgery; lower extremity ulceration or gangrene; or kidney failure. |
30 days, 9 months | |
Secondary | Technical Success | Technical success is defined as successful delivery and deployment of the iCAST™ RX Stent System with = 30% residual angiographic stenosis after covered stent deployment (including post-dilatation) assessed via quantitative vascular analysis (QVA) by an independent core laboratory. | Day of Procedure | |
Secondary | Acute Procedural Success | Acute procedural success is defined as technical success without the occurrence of MAE prior to hospital discharge. | Day of Procedure, prior to hospital discharge | |
Secondary | Target Lesion Revascularization (TLR) | Target Lesion Revascularization (TLR) is measured as the proportion of subjects-lesions that require a clinically-driven reintervention of the target lesion through 9 months.
a. A clinically-driven TLR is defined as a TLR (percutaneous balloon angioplasty (PTA), bare metal stent or repeat covered stent deployment, or surgical bypass) due to documented recurrent hypertension from 30-days post-procedure level and/or deterioration in renal function from baseline value, associated with angiographic core laboratory adjudication of a = 60% diameter covered stent restenosis. |
9 months | |
Secondary | Rate of Incidental TLR | The rate of incidental TLR is the rate of TLRs not meeting the definition of a clinically-driven TLR. | 9 months | |
Secondary | Systolic Blood Pressure (SBP) Control | The change in SBP from baseline to 30 days | Baseline and 30 days | |
Secondary | SBP Control | The change in SBP from baseline to 9 months | Baseline and 9 months | |
Secondary | Secondary Patency Rate | Secondary patency rate at 9 months after a clinically-driven TLR which restores patency after total occlusion. | 9 months | |
Secondary | Change in Number of Anti-Hypertensive Medications | Change in number of anti-hypertensive medications as compared to baseline. | Baseline and 9 months | |
Secondary | Change in Renal Function | Renal function compared to baseline as measured by estimated Glomerular Filtration Rate (eGFR) at 30 days. | Baseline and 30 days | |
Secondary | Change in Renal Function | Renal function compared to baseline as measured by estimated Glomerular Filtration Rate (eGFR) at 9 months. | Baseline and 9 months |
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT02528149 -
Renal Arteries Dysplastic Aneurysms: Anatomopathological and Genetic Study
|
N/A | |
Completed |
NCT02476526 -
Safety of Low Dose IV Contrast CT Scanning in Chronic Kidney Disease
|
Phase 4 | |
Completed |
NCT00209391 -
A Safety & Efficacy Clinical Study to Evaluate the Narrowing of the Renal Arteries While Using Gadodiamide
|
Phase 3 | |
Completed |
NCT02266394 -
Hypoxia and Inflammatory Injury in Human Renovascular Hypertension
|
Phase 1 | |
Recruiting |
NCT02388139 -
Cardiovascular, Renal and Metabolic Profile in Patients With Acute Myocardial Infarction (REN-ACS)
|
N/A | |
Active, not recruiting |
NCT01023373 -
Revascularization of Renal Artery Stenosis Versus Medical Therapy for the Treatment of Ischemic Nephropathy
|
Phase 4 | |
Recruiting |
NCT05603221 -
Renal Perfusion Assessment in the Endovascular Treatment of Renal Artery Stenosis
|
||
Recruiting |
NCT03252639 -
A Study of Using Parenchymal Blood Volume(PBV) for Endovascular Treatment of Renal Arterial Stenosis
|
N/A | |
Completed |
NCT00235157 -
A Comparison of Coated and Uncoated Stents in Renal Artery Treatment.
|
Phase 2 | |
Completed |
NCT00001313 -
Evaluation of Patients With Known or Suspected Heart Disease
|
N/A | |
Not yet recruiting |
NCT05612438 -
RADIX 2 RENAL STENT Post-Market Retrospective Study
|
||
Withdrawn |
NCT03914157 -
Ultrasound Wave Therapy for Post-stenotic Microvascular Remodeling
|
N/A | |
Completed |
NCT01128933 -
Renal Fractional Flow Reserve in Renal Artery Stenting
|
N/A | |
Recruiting |
NCT03594786 -
Impact of Supra-renal Fixation of EVAR on Hemodynamics of Renal Arteries
|
N/A | |
Completed |
NCT00885768 -
Prevalence of Renal Artery Stenosis in Patients Referred for Cardiac Catheterization
|
Phase 3 | |
Completed |
NCT04423458 -
Evaluation of Advanced US Tools in Assessing Allograft Complications
|
||
Recruiting |
NCT02655341 -
Hydration Status Assessment Through Body Composition Monitoring in Patients With Acute Myocardial Infarction
|
N/A | |
Completed |
NCT01576835 -
Renal Artery Contrast-Free Trial
|
Phase 4 | |
Completed |
NCT01057316 -
Formula PTX Renal Stent Clinical Study
|
N/A | |
Completed |
NCT00631540 -
REFORM Clinical Study: Treatment of Renal Artery Stenosis With the Formula Balloon-Expandable Stent
|
N/A |