Clinical Trials Logo

Clinical Trial Summary

Percutaneous transhepatic biliary drainage (PTBD) procedures are associated with an elevated radiation exposure for the patient. In the recently published guideline of the Federal Office for Radiation Protection in Germany diagnostic reference levels (DRLs) for dose area products (DAP) are not defined for PTBD procedures due to insufficient data. The aim of this retrospective study is to give a nation-wide survey on patients radiation exposure in different PTBD procedures considering factors that may have an impact on increased radiation exposure like fluoroscopic-guided versus ultrasound-guided bile duct puncture.


Clinical Trial Description

Percutaneous transhepatic biliary drainage (PTBD) procedures are associated with an elevated radiation exposure for the patient. Usually, radiation exposure in radiological interventions is measured by the dose area product (DAP). Diagnostic reference levels (DRLs) are based on the third quartiles (Q3) of the pooled dose area product (DAP) for the known interventional procedures. They have been introduced in the 1980s by the International Commission on Radiological Protection's (ICRP's) to reduce patients radiation exposure. In the recently published guideline of the Federal Office for Radiation Protection in Germany in 2016 DRLs are not defined for PTBD procedures due to insufficient data. Procedure complexity due to different techniques, patient anatomy, lesion characteristics and disease severity makes it difficult to define DRLs in this fluoroscopy-guided intervention. The ICRP recently published some recommendations on DRLs in medical imaging including radiological interventions. As DRLs are often missing in this field, it was suggested to analyze national data sets comprising dosimetric data from a large number of facilities. The aim of this retrospective study is to give a nation-wide survey on patients radiation exposure in different PTBD procedures considering factors that may have an impact on increased or decreased radiation exposure like fluoroscopic-guided versus ultrasound-guided bile duct puncture. A questionnaire was sent to 200 gastroenterological and radiological departments in university and non-university hospitals to analyze the last 10 - 30 consecutively performed PTBD procedures. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT03538782
Study type Observational
Source Theresienkrankenhaus und St. Hedwig-Klinik GmbH
Contact
Status Completed
Phase
Start date March 15, 2018
Completion date October 15, 2018

See also
  Status Clinical Trial Phase
Completed NCT03649451 - Reference Dose Levels During Fluoroscopically Guided Procedures in Operating Rooms
Completed NCT03305978 - Pulmonary Nodule Detection: Comparison of an Ultra Low Dose vs Standard Scan. N/A
Recruiting NCT04139096 - Genetic Susceptibility to Radiation Induced Thyroid Cancer
Completed NCT01430975 - Prospective Evaluation of Strontium in Patients After CardioGen-82 PET MPI Scanning at Two Clinical Sites N/A
Completed NCT01424774 - Prospective Evaluation of Strontium in Patients After CardioGen-82 PET MPI Scanning N/A
Completed NCT00378053 - A Prospective Study of Radiation Exposure to Surgeons N/A
Recruiting NCT05561439 - Individual Dosimetric Monitoring of Workers During Interventional Radiology and Cardiology Procedures for Cardiologists and Radiologists in France
Completed NCT04078165 - Suspended Personal Protection System Versus Conventional Protection (Aka Zero-Gravity vs Shield and Apron) N/A
Recruiting NCT04694391 - Genomic Study of Relapse Esophageal Cancer After Radiotherapy
Not yet recruiting NCT04403815 - Radiation Exposure During Coronary Procedures According to Vascular Access
Recruiting NCT04285944 - Operator Radiation Protection During Cardiac Catheterization Using Mavig X-ray Protective Drapes®. N/A
Completed NCT04363190 - Genomic Instability in Vascular Surgeons
Completed NCT04404257 - Reduce Radiation Exposure in Fluoroscopic Interventions Evaluation N/A
Recruiting NCT04678258 - Zero Fluoroscopy Voltage Guided vs. Linear CTI Ablation N/A
Recruiting NCT03386500 - Safety Study of BMX-001 (Radio-protector) in Patients With Newly Diagnosed Anal Cancer Phase 1/Phase 2
Recruiting NCT05833516 - Hyper Adduction of Right Radial Artery/Arm vs Left Drag Over Technique
Recruiting NCT03946280 - Utility of 3D Navigation to Reduce Ionizing Radiation in Common Flutter Ablation. Study of Personnel and Patient Dosimetry N/A
Completed NCT03985488 - Radiation Exposure Assessment in Fluoroscopy
Completed NCT03605030 - Reducing Radiation Exposure to Operators During Invasive Cardiac Procedures N/A
Recruiting NCT02689908 - Individualized Radiation Dose Control N/A