Quadriplegia Clinical Trial
Official title:
A Feasibility Study of the Ability of the Neural Prosthetic System 2 to Provide Direct Closed Loop Cortical Control of Extracorporeal Devices Through the Use of Intracortical Microstimulation in Patients With Quadriplegia
This research study is being conducted to develop a brain controlled medical device, called a brain-machine interface. The device will provide people with a spinal cord injury some ability to control an external device such as a computer cursor or robotic limb by using their thoughts along with sensory feedback. Development of a brain-machine interface is very difficult and currently only limited technology exists in this area of neuroscience. Other studies have shown that people with high spinal cord injury still have intact brain areas capable of planning movements and grasps, but are not able to execute the movement plans. The device in this study involves implanting very fine recording electrodes into areas of the brain that are known to create arm movement plans and provide hand grasping information and sense feeling in the hand and fingers. These movement and grasp plans would then normally be sent to other regions of the brain to execute the actual movements. By tying into those pathways and sending the movement plan signals to a computer instead, the investigators can translate the movement plans into actual movements by a computer cursor or robotic limb. A key part of this study is to electrically stimulate the brain by introducing a small amount of electrical current into the electrodes in the sensory area of the brain. This will result in the sensation of touch in the hand and/or fingers. This stimulation to the brain will occur when the robotic limb touches the object, thereby allowing the brain to "feel" what the robotic arm is touching. The device being used in this study is called the Neuroport Array and is surgically implanted in the brain. This device and the implantation procedure are experimental which means that it has not been approved by the Food and Drug Administration (FDA). One Neuroport Array consists of a small grid of electrodes that will be implanted in brain tissue and a small cable that runs from the electrode grid to a small hourglass-shaped pedestal. This pedestal is designed to be attached to the skull and protrude through the scalp to allow for connection with the computer equipment. The top portion of the pedestal has a protective cover that will be in place when the pedestal is not in use. The top of this pedestal and its protective cover will be visible on the outside of the head. Three Neuroport Arrays and pedestals will be implanted in this study so three of these protective covers will be visible outside of the head. It will be possible to cover these exposed portions of the device with a hat or scarf. The investigators hope to learn how safe and effective the Neuroport array plus stimulation is in controlling computer generated images and real world objects, such as a robotic arm, using imagined movements of the arms and hands.
The long-term objective of this application is to understand cortical processing of sensory to motor transformations within the human cerebral cortex. A vast number of computations must be performed to achieve sensory-guided motor control. Standing out among these computations, visual information of the goals of action must be transformed from the coordinates of the retina to the coordinates of effectors used for movement, for instance limb coordinates for reaching under visual guidance and to world coordinates for interactions in the environment. Once an object is grasped, somatosensory signals from the hand are required for dexterous manipulation of grasped objects. Internal models within the sensory motor pathway are essential for estimating the current state of the body and the external environment, accounting for lags in sensory feedback, and calibrating the body to the environment. We will use the rare opportunity of being able to record from populations of single neurons in a clinical study designed to develop neural prosthetics for tetraplegic participants paralyzed by spinal cord injuries. Cortical implants of microelectrode arrays will be made within three key locations in the sensorimotor system: primary motor cortex, primary somatosensory cortex, and posterior parietal cortex. These microelectrode arrays enable both recording and intracortical microstimulation. We will test the hypothesis that somatosensory and motor cortex represent imagined reaches in hand coordinates, but posterior parietal cortex is task dependent, and it's population neural activity can flexibly change coordinate frames depending on the effector used in the task. Percepts evoked by intracortical microstimulation and imagined sensations will be used to understand the representation of cutaneous and proprioceptive information within primary somatosensory cortex and posterior parietal cortex. The hypothesis to be tested is that imagined sensation and electrically evoked sensations are highly overlapping - not just in primary somatosensory cortex but also in posterior parietal cortex. Lastly, we hypothesize that the posterior parietal cortex contains in humans an internal model of state estimation that shows plasticity for both natural and brain-control behaviors and transfers this learning to motor cortex. These studies will not only greatly advance our understanding of the human sensorimotor cortical circuit, but also will provide basic knowledge for the design of future neural prosthetics. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT00385918 -
Robotically Assisted Treadmill Training in Spinal Cord Injury (SCI)
|
N/A | |
Completed |
NCT04306328 -
Neural Stimulation for Hand Grasp
|
N/A | |
Recruiting |
NCT05321017 -
Wrist Extensor MEP Up-conditioning for Individuals With Incomplete Spinal Cord Injury
|
N/A | |
Recruiting |
NCT01958086 -
Visuomotor Prosthetic for Paralysis
|
N/A | |
Terminated |
NCT01498991 -
Spinal Cord Injury Leg Rehabilitation
|
Phase 1/Phase 2 | |
Terminated |
NCT04265560 -
Progressive Resistance Training in Acute Spinal Cord Injury
|
N/A | |
Completed |
NCT01124292 -
Evaluation of a Tongue Operated Assistive Technology for Individuals With Severe Paralysis
|
Phase 1 | |
Completed |
NCT00270855 -
Exercise to Reduce Obesity in Spinal Cord Injury
|
N/A | |
Completed |
NCT00656149 -
In-home Telerehabilitation for Quadriplegic Hand Function
|
Phase 2/Phase 3 | |
Active, not recruiting |
NCT00059553 -
Retraining Walking After Spinal Cord Injury
|
Phase 2/Phase 3 | |
Terminated |
NCT00004415 -
Study of Combined Intercostal and Diaphragm Pacing for Artificial Respiration in Quadriplegic Patients
|
N/A | |
Completed |
NCT00632528 -
MEOPA to Improve Physical Therapy Results After Multilevel Surgery
|
Phase 3 | |
Completed |
NCT01899664 -
Upper Extremity Surgery in Spinal Cord Injury
|
N/A | |
Completed |
NCT00221767 -
Medico-economical Impact of the Brindley Neurosurgical Technique in France
|
N/A | |
Completed |
NCT03482310 -
Restoring High Dimensional Hand Function to Persons With Chronic High Tetraplegia
|
N/A | |
Recruiting |
NCT06429735 -
Precise Robotically IMplanted Brain-Computer InterfacE
|
N/A | |
Completed |
NCT02354625 -
The Safety of ahSC in Chronic SCI With Rehabilitation
|
Phase 1 | |
Completed |
NCT01911559 -
Effectiveness of Standing Frame on Constipation in Children With Cerebral Palsy
|
N/A | |
Completed |
NCT00010374 -
Electrical Activation of The Diaphragm for Ventilatory Assist
|
N/A | |
Withdrawn |
NCT02861612 -
Nerve Transfers to Restore Hand Function in Spinal Cord Injury
|