Endodontically Treated Teeth Clinical Trial
Official title:
An In-Vivo Evaluation of the Accuracy of Different Generation Apex Locators and Tactile Sense in Primary Teeth
The aim of this study was to evaluate the effectiveness of tactile sense, digital periapical radiograph and two different varieties of electronic apex locators at working length determination in primary molars. A total of 30 infected mandibular primary second molar teeth in twelve children aged between 5 and 8 years were included in this study. Working length determination was performed using tactile sense, radiographic method and two different varieties of electronic apex locators (ProPex Pixi® and Ipex®) separately.
The teeth were first anaesthetized with Ultracaine Ds-Forte (Sanofi Aventis, İstanbul, Türkiye) and then isolated with rubber dam. Caries was removed and access cavity was prepared using a round diamond bur with copious water in each tooth. Barbed broaches were used to extirpate the pulpal tissue and 2.5 % sodium hypochlorite was used as the irrigation solution. Sterile cotton pellets were used to dry the cavity. For working length determination, the groups were performed as; Group 1: Tactile Sense Method Group 2: Radiographic Method (digital periapical radiography) Group 3: Ipex® EAL Group 4: Propex® pixi EAL The measurement techniques given in the groups were used in each root canal of all primary molars (n=90). Root canal length determination by tactile sense method: In the determination of working length using tactile sense, a K-file with the tip that best adjusted to the apical area was selected and gently inserted into the canal until the operator felt the narrowest region. The silicone stop was then placed at the coronal reference, and tooth length considering the end of the root was measured with an endodontic ruler (0.5mm accuracy). Root canal length determination by radiographic method: In group 2, working length determination was performed with digital periapical radiograph (……………….). Before the radiographic evaluation, the protective thyroid lead and protective lead apron were used for all children. Digital periapical radiograph was taken with using paralleling technique while the files were in the canals. X-ray positioning device (FPS 3000-Film positioning system complete, TPC Advanced Technology Inc., California, USA) was used to standardize the distances between the source and the tooth, and the tooth and the film. Cusp adjacent to the canal was taken as the occlusal reference. Files, 1 mm shorter than the tooth length as recorded according to the preoperative radiograph, were inserted in the canals. The difference between the tip of the file and the end of the root was calculated on the image. In case the file had not passed the apex, this amount and the original length was calculated. In case the file had passed the apex, the amount was subtracted from the original length. Lastly, 1 mm was subtracted from this adjusted length to confirm the cemento-dentinal junction and recorded as radiographic working length. Root canal length determination by EALs: The electronic working length determination was performed either with Ipex®/Goup 2 (NSK Ltd, Tokyo, Japan) or ProPex Pixi®/Group 3 (Dentsply Maillefer, Ballaigues, Switzerland) apex locators. Lip clip was attached to patients' lower lip in order to complete the circuit. Then, the root canals were moistened with 0.9% saline solution, and a no.15 K- file (Dentsply Maillefer, Baillaigues, Switzerland) mounted to the holder was gently inserted till "0.5" signaled on the screen, meaning that the tip of file was at the apical constriction. If the reading was stable for at least 5 seconds, the file was pulled back and the length between the silicone stopper and the tip of the file was measured with an endodontic ruler. Endodontic treatment was completed in same appointments. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Not yet recruiting |
NCT06447519 -
Multiple-Visit RCT in Teeth With SAP: Interappointment Dressing or Not?
|
N/A | |
Not yet recruiting |
NCT05476419 -
Apical Gap Length and Adaptation of Zirconia Post Using Intraoral and Extraoral Scan of Silicon Impression Technique
|
N/A | |
Completed |
NCT03478241 -
Postoperative Pain Intensity Associated With the Use of Different Nickel Titanium Instrumentation Systems
|
N/A | |
Recruiting |
NCT04528979 -
Outcome of Endodontic Treatment and Retreatment With a Bioceramic Sealer
|
N/A | |
Recruiting |
NCT04527705 -
Outcome of Endodontic Retreatment in One or Two Visits
|
N/A | |
Completed |
NCT05381298 -
Deep Margin Elevation Vs Crown Lengthening
|
N/A | |
Active, not recruiting |
NCT03161639 -
Influence of Working Length Methods in the Performance of Pulpectomies in Primary Teeth
|
N/A | |
Completed |
NCT06226740 -
Effectiveness of Different Obturation Techniques
|
N/A | |
Completed |
NCT04310254 -
Effect of Different Final Irrigation Protocols on Postoperative Endodontic Pain in Devital Teeth
|
N/A | |
Completed |
NCT03841370 -
Tooth Crown Discoloration Caused by Endodontic Treatment
|
||
Recruiting |
NCT03704857 -
Different Endodontic Treatment Techniques in Postoperative Symptoms, Apical Repair, Longevity of Rehabilitations, and Oral Health-related Quality of Life
|
N/A | |
Completed |
NCT04518371 -
Clinical Performance of Milled Resin Composite in Restoration of Endodontically Treated Posterior Teeth Over One Year
|
N/A | |
Completed |
NCT04561167 -
Clinical Performance of the Indirect Resin Composite Restorations in Endodontically Treated Teeth
|
N/A | |
Not yet recruiting |
NCT04580862 -
Postoperative Pain Endodontic Retreatment
|
N/A | |
Completed |
NCT04511117 -
Endocrowns as Permanent Restorations for Endodontically Treated Permanent Molars in Young Age: Two-Year Follow up
|
N/A | |
Recruiting |
NCT05084742 -
Long-term Performance and Safety of Biodentine™ in Patients Treated for Endodontic Indications
|
||
Not yet recruiting |
NCT04023357 -
Marginal Integrity and Clinical Evaluation of Polyetheretherketone (PEEK) Versus Lithium Disilicate (E-max) Endocrowns.
|
N/A | |
Not yet recruiting |
NCT03713918 -
Clini Asses of Retentn,Pt Satisfactn and Recurrent Caries of Endocrs Versus Post Crs Using Reinforced Lithium Silicate
|
N/A | |
Not yet recruiting |
NCT06450938 -
No Code Artificial Intelligence to Detect Radiographic Features Associated With Unsatisfactory Endodontic Treatment
|
N/A | |
Not yet recruiting |
NCT06226870 -
Outcome of NSRCT Versus VPT in Management of Teeth With Symptomatic Irreversible Pulpitis Associated With Apical Periodontitis
|
N/A |