View clinical trials related to Pseudophakia.
Filter by:The primary objective of this study is to compare the postoperative visual acuity curves of patients that underwent one of the following surgical procedures: Insertion of an extended depth of focus intraocular lens with digital assistance and insertion of an extended depth of focus intraocular lens without digital assistance.
The primary objective of this study is to identify how many focal points and at which distances are necessary for reliable visual curve formation and area of the curve (AoC) calculation using mathematical models and comparing the results to measurements acquired from participants that underwent uncomplicated pseudophakic presbyopia surgery.
This is a prospective comparative study that will be conducted at one clinical site in the United States, in which subjects who sign an informed consent form and fulfil all inclusion and exclusion criteria, will have OCT scans obtained using the test and the predicate devices. There will be two main types of analyses performed as part of this study, including 1) a precision analysis, and 2) an agreement analysis. The precision analyses will be conducted utilizing all complete complements of acceptable scans from the test devices and predicate device for each of the 3 configurations. A complete complement of acceptable scans can be defined as subjects having 3 acceptable replicate scans on each of the 3 devices, at each of the 3 configurations. This is also synonymous with 3 scans for each of the 3 configurations on all 3 devices. If subjects have more than 3 acceptable scans per configuration on a device, only the first 3 will be considered for analyses. The agreement analysis will be conducted utilizing the first set of acceptable scans from each instrument for all overlapping measurement types (for all measurement types two or more of the devices have in common) related to performance endpoints.
This is a non-interventional, prospective, observational study of the outcomes for post myopic refractive surgery patients following successful, uncomplicated cataract surgery with bilateral implantation of the Vivity IOL (DAT***/CCWET*). Patients will be assessed for monocular and binocular distance, intermediate, and near vision.
The goal of this observational study is to learn about the Asqelio monofocal intraocular lens (IOL) model QLIO130C in patients undergoing cataract surgery. The aim of the study is to evaluate the lens implementation safety and efficacy after at least 24 months.
Background: - The Tecnis Synergy intraocular lens (IOL) has a claim to allow patients to experience continuous high-contrast vision from far through near even in low-light conditions. - A J&J-sponsored post marketing study done outside of the US claim superiority of range of vision for the Tecnis Synergy IOL over the PanOptix IOL. Hypothesis: - Patients with bilateral Panoptix IOLs have non-inferior distance, intermediate, and near visual acuity compared to patients with bilateral Synergy IOLs in both photopic and mesopic conditions with less glare, haloes, and/or starbursts. Unmet Medical Need: - There is a need to look at patient visual outcomes and the visual disturbance profile comparing trifocal technology with combined EDOF/Bifocal technology in the United States.
Medicontur hydrophilic posterior chamber monofocal intraocular lens (IOLs) are indicated to improve vision at far distance in adults with cataract and/or ametropia (hyperopia, myopia), secondarily to removal of the crystalline lens. The intraocular lens is intended to be surgically implanted into the eye with the purpose of restoring optical function in the aphakic eye to provide an optical system with high predictability of the precalculated dioptric power. The study will be performed partially as a retrospective study with patients enrolled who had been implanted with 690AD or 690ADY IOLs mono- or binocularly between September 2021 - March 2022. Data from five visits will be collected: - Baseline preoperative (maximum 90 days prior to surgery)- retrospective - IOL implantation Day 0 - retrospective - Postoperative visit at Day 1 (+/- 0 days) - retrospective - Postoperative visit at 1 month (+/- 2 weeks) - retrospective - Postoperative visit at 12 months (+/- 3 months) - consent and prospective visit
The clinical investigation objective is to evaluate safety and performance outcomes of trifocal IOL implantation to improve vision in patients with cataract and/or ametropia (hyperopia, myopia) and/or presbyopia. Retrospective data from preoperative status up to 12 month postoperative status will be collected from patients that were implanted with Medicontur's 640PM intraocular lens: - Preoperative status: Preoperative Screening and Baseline - Surgery: IOL implantation - M1: 1 month +/- 2 weeks postoperative follow-up - M3: 3 months +/- 1 month postoperative follow-up - M12: 12 months +/- 3 months postoperative follow-up
Single-center, retrospective, open-label observational study aiming to evaluate visual outcomes and patient satisfaction after bilateral implantation of Isopure® EDOF-IOL with a mono-minovision target.
This is a non-interventional prospective, single center, bilateral, non-randomized, open-label, observational clinical study. All patients will have had bilateral implantation of an Eyhance IOL at the time of cataract surgery. These patients will then be compared to assess which patient biometric properties (such as spherical aberration, q value, pupil size, etc.) lead to an overall increase in near or intermediate vision as well as overall patient satisfaction.