Clinical Trials Logo

Clinical Trial Summary

The prevalence of valvular heart disease is on the rise along with the aging society and the generalization of echocardiography. Furthermore, the rheumatic valvular heart disease is much more prevalent in Asia than in Western countries, and the frequency of valve disease is higher in Asia. The effect of an implantable cardioverter defibrillator (ICD) in the primary prevention of sudden cardiac death in ischemic cardiomyopathy is well established and has become a standard of care. However, there is limited research on the effect of ICD implantation for primary prevention in patients with heart failure due to valvular heart disease. In a small study, the incidence of fatal cardiac arrhythmia was lower in patients with valvular cardiomyopathy (5%) who received ICD implantation for primary prevention than in those with ischemic cardiomyopathy. But there is also a report that the appropriate ICD treatment is not different from that of ischemic heart disease in valvular heart disease patients. Therefore, it is necessary to study the primary prevention effect of ICD on valvular cardiomyopathy in a larger number of patients. The purpose of this study was to investigate the effect of ICD on the prevention of sudden cardiac death in patients with heart failure due to valvular heart disease through prospective, multicenter, and observational studies.


Clinical Trial Description

n/a


Study Design


Related Conditions & MeSH terms


NCT number NCT03590730
Study type Observational
Source Keimyung University Dongsan Medical Center
Contact
Status Terminated
Phase
Start date November 15, 2017
Completion date July 15, 2021

See also
  Status Clinical Trial Phase
Completed NCT02923726 - Assessment of Primary Prevention Patients Receiving An ICD - Systematic Evaluation of ATP N/A
Recruiting NCT05175937 - REal World Assessment for Patients Implanted With Implantable CardioverTer DefibrIllatOr Using Bluetooth Technology
Completed NCT02026102 - A Pilot Trial of Patient Decision Aids for Implantable Cardioverter-Defibrillators (ICDs) N/A
Completed NCT01262508 - Development of Algorithms to Predict Hemodynamic Instability N/A
Completed NCT00998218 - Effect of Ranolazine on Arrhythmias and Microvolt T- Wave Alternans (MVTWA) Patients With LV Dysfunction Phase 3
Completed NCT00845286 - Marathon, Genetics, Inflammation and the Cardiovascular System: MAGIC-Trial N/A
Active, not recruiting NCT00562757 - Prospective Study to Identify Patients at Risk of Dangerous Ventricular Arrhythmias N/A
Completed NCT00622453 - Arrhythmias in Myotonic Muscular Dystrophy N/A
Completed NCT03833843 - Sudden Cardiac Death in Systemic Right Ventricle
Completed NCT04024865 - Domperidone and Risk of Serious Cardiac Events in Postpartum Women
Recruiting NCT05799833 - Low QRS Voltages in Young Healthy Individuals and Athletes
Recruiting NCT05694572 - Post-market Surveillance of Micorport CRM Cardiac Implantable Electronic Devices
Not yet recruiting NCT03622307 - Subcutaneous ICD Therapy Combined With VT Ablation for the Secondary Prevention of Sudden Cardiac Death N/A
Recruiting NCT02056509 - The Effect of Chest Compression and Ventilation Coordination During Cardiopulmonary Resuscitation. N/A
Recruiting NCT02058771 - Utilising Lifemap to Investigate Malignant Arrhythmia Therapy
Terminated NCT01948206 - Study of Paced QRS Duration as a Marker of Sudden Cardiac Death N/A
Completed NCT01227785 - Next Generation INCEPTA Implantable Cardioverter Defibrillator (ICD) and Cardiac Resynchronization Therapy (CRT-D) Field Following Study N/A
Terminated NCT00524862 - Standard Drug Therapy vs. Implanted Defibrillator for Primary Prevention of Sudden Cardiac Death N/A
Completed NCT00534300 - Intravenous n-3 Fatty Acids and Ventricular Tachycardia in Patients With Implantable Cardioverter Defibrillator (ICD)-Pacemaker Phase 1/Phase 2
Recruiting NCT00181233 - Imaging Techniques for Identifying Factors of Sudden Cardiac Death Risk