Clinical Trials Logo

Clinical Trial Summary

A retrospective consecutive population of patients treated with cementless total hip arthroplasty with ceramic-on-ceramic bearing surfaces due to post-traumatic osteoarthritis due to acetabular fractures will be selected. The aim of this retrospective study is to evaluate the long-term clinical and radiographic results of this implant in such a specific cohort. The secondary aim of the sudy is to provide the complication rate and the failure rate of the cohort. A descriptive analysis of the failures will be provided as well.


Clinical Trial Description

Total hip arthroplasty (THA) is the recommended treatment to restore functionality and control pain in post-traumatic hip osteoarthritis due to acetabular fractures. However, THA in post-traumatic osteoarthritis following acetabular fractures is a complex procedure and it is burdened with occasional failures. Modest long-term outcomes have been reported, generally lower than conventional THAs performed due to osteonecrosis or primary osteoarthritis: 10-year clinical results are usually good but not excellent (average Harris Hip score: 88), 10-year revision rate is between 15% and 26%. In review study about the complications of post-traumatic THAs, 30% of ossifications, 4.4% of dislocations, 5.6% of infections, and 2.1% of neurovascular lesions were reported: all the percentages were higher than in primary conventional THAs.

The most critical issues are related to the young age of the patients, to the anatomical changes affecting the periarticular tissues, to the presence of hardware and to the greater exposure to septic complications. All these factors may prevent the surgeon to achieve a good cup positioning and a satisfying outcome. However a correct surgical technique, associated with meticulous pre-operative planning and the use of low-wear implants can improve the clinical result and the long term survival rates.

However, the literature about mid-to-long-term studies about post-traumatic THAs is scarce (currently 5 with an average follow-up of at least 5 years). Furthermore, these studies often include outdated implants, positioned with invasive surgical techniques and with removal of all previous hardware. Therefore, a long-term study (minimum 10-year follow-up) involving more recent implants, with modern articular couplings demonstrating low wear (such as ceramic-on-ceramic), and performed with minimally invasive technique and pre-operative CT-guided planning, would be desirable.

The aim of this study is to describe the survival rates and the long-term clinical and radiological outcome (minimum 10-year follow-up) of cementless THAs, with ceramic-on-ceramic couplings, performed with minimally-invasive technique and CT guided pre-operative planning, in post-traumatic osteoarthritis due to acetabular fractures ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04034043
Study type Observational
Source Istituto Ortopedico Rizzoli
Contact
Status Completed
Phase
Start date July 15, 2019
Completion date August 20, 2019

See also
  Status Clinical Trial Phase
Active, not recruiting NCT03326804 - H1 Hip Resurfacing Arthroplasty
Not yet recruiting NCT04257682 - Regional Anesthesia in Total Hip and Knee Arthroplasty Phase 4
Completed NCT02876120 - The STavanger osteoARThritis Study N/A
Terminated NCT02231567 - Neurocognitive Rehabilitation After Hip Replacement N/A
Recruiting NCT02174965 - Wear and Migration in the Corin Mini-Hip/Metafix and ECIMA Polyethylene N/A
Completed NCT01506024 - Minimal Invasive Surgery in Total Hip Arthroplasty Patients; Short- and Long Term Results N/A
Active, not recruiting NCT04070027 - Progressive Resistance Training Versus Total Hip Arthroplasty in Patients With Hip Osteoarthritis N/A
Withdrawn NCT04421196 - Opioid-free Total Hip Arthroplasty N/A
Not yet recruiting NCT05960903 - Patient Satisfaction After Primary THA In Assiut University
Completed NCT04084704 - A Prospective Evaluation of the Cingal Injection for Hip Osteoarthritis N/A
Not yet recruiting NCT04018690 - Project Arthritis Recovering Quality of Life Through Education - Hip N/A
Completed NCT03648060 - Efficacy of a Digital Biofeedback System for Home-based Rehabilitation After Total Joint Replacement N/A
Recruiting NCT05497349 - Use of Leukocyte-Rich PRP or Leukocyte-Free PRP in the Treatment of Hip Osteoarthritis N/A
Active, not recruiting NCT04879732 - RSA - ACTIS Hip Stem N/A
Active, not recruiting NCT05142462 - Post Market Clinical Follow-up of EUROSCUP Fixe Acetabular Cup
Recruiting NCT04665908 - PT-led Triage for Patients With Hip o Knee Osteoarthritis N/A
Completed NCT04648956 - Arabic Version of the ICOAP Questionnaire
Recruiting NCT05465096 - Treatment of Osteoarthritis of the Hip Joint With Intra-articular Injection of Microfractured Autologous Adipose Tissue Containing Mesenchymal Stromal Cells. N/A
Completed NCT02884531 - Patient Education and Basic Body Awareness Therapy in Hip Osteoarthritis: a Randomized Controlled Trial N/A
Completed NCT03031314 - Comparison of Knotless Barbed Suture and Standard Suture in Knee Replacement Patients N/A