Failed Back Surgery Syndrome Clinical Trial
Official title:
Randomized, Single-blind, Multicenter, Crossover, Controlled Clinical Trial to Compare Difference on the Visual Analogue Scale With Two Modes of Spinal Cord Stimulation in Patients With Post-Laminectomy Syndrome in Testing Phase
Traditionally, pain relief through spinal cord stimulation has been associated with the appearance of paresthesia in the affected area. Several parameters are set to maximize the overexposure zone, such as frequency,and pulse width. Although this technique has improved pain in many patients, paresthesia itself can be uncomfortable. Traditionally, the occurrence of paresthesias has been considered to be a predictor of success in pain elimination, while the non-occurrence of paresthesias would indicate failure. So far, few studies have reported pain relief below the threshold of onset of paresthesia. Some clinical trials for pathologies other than the one considered in this study have achieved relief below the threshold by reducing the amplitude of the stimulus. Recently, however, it has been observed in a pilot study that, by increasing the frequency of spinal cord stimulation to 1 kilohertz, it is possible to significantly improve pain relief compared to less frequent conventional stimulation based on the occurrence of paresthesias. A recent review by the Cochrane Library concluded that conventional spinal cord stimulation for pain relief of Failed Back Surgery Syndrome (or FBSS) requires further clinical studies and better designs to demonstrate its superiority over other therapeutic options. Therefore, although spinal cord stimulation is accepted by the Food and Drug Administration (FDA) and the European Medicines Agency (EMA), new techniques are being introduced that offer better results in terms of pain relief. Among these techniques, there is the high frequency mode, which allows avoiding the annoying sensation of paresthesia that substitutes pain with the conventional technique. In order to provide greater rigour and scientific quality, the present study is proposed, in which the conventional spinal cord stimulation (CME) technique (control branch or CME) is compared with paresthesias and a standard frequency (60 hertz) with a high frequency (1000 hertz) EVOLVE system (Evolve workflow - standardized guidance to simplify the trial and implant experience and optimize patient outcomes) (experimental branch or EME) by means of a design with a high degree of scientific evidence, randomising the global sample of patients to each of the two branches of stimulation in the study (blind to the patient) and crossing the branches after a period of washing
n/a
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT01701804 -
The Effectiveness of Non-surgical Integrative Package on Failed Back Surgery Syndrome
|
||
Not yet recruiting |
NCT01185665 -
Predicting Outcome of Transcutaneous Electrical Nerve Stimulator (TENS) in Failed Back Surgery Syndrome
|
N/A | |
Terminated |
NCT00974623 -
Bone Graft Materials Observational Registry
|
N/A | |
Recruiting |
NCT01181817 -
Evaluation of the Brain Activity During Spinal Cord Stimulation in Failed Back Surgery Syndrome Using Functional MRI and MRS
|
N/A | |
Recruiting |
NCT04732325 -
Sensory Testing of Multiple Forms of Spinal Cord Stimulation for Pain
|
N/A | |
Completed |
NCT05018377 -
Effectiveness and Safety of Percutaneous Adhesiolysis Using Rac'z Catheter Versus Navi Catheter in Management of Failed Back Surgery Syndrome
|
N/A | |
Not yet recruiting |
NCT04268602 -
The Effect of Intradermal Local Anesthetic Injection in FBSS (Failed Back Surgery Syndrome)
|
N/A | |
Recruiting |
NCT03957395 -
Comparison of Effectiveness of Tonic, High Frequency and Burst Spinal Cord Stimulation in Chronic Pain Syndromes
|
N/A | |
Completed |
NCT04121104 -
Electrodermal Activity and Respiration in Patients Treated With Spinal Cord Stimulation
|
N/A | |
Recruiting |
NCT05068011 -
Differential Target Multiplexed Spinal Cord Stimulation
|
||
Not yet recruiting |
NCT06034041 -
The Effect of Mediclore as an Anti-adhesion Agent and Safety in Full-endoscopic Spine Surgery: a Preliminary Study
|
Phase 4 | |
Completed |
NCT02837822 -
Effects of Spinal Cord Stimulation on Sensory Perceptions of Chronic Pain Patients
|
N/A | |
Completed |
NCT01966250 -
Electroacupuncture as a Complement to Usual Care for Patients With Non-acute Pain After Back Surgery
|
N/A | |
Completed |
NCT00018876 -
Low-Dose Radiation to Prevent Complications of Back Surgery
|
Phase 1 | |
Completed |
NCT03523000 -
Determining the Prognostic Value of Continuous Intrathecal Infusion
|
Phase 4 | |
Completed |
NCT01776749 -
Subcutaneous Stimulation as Add on Therapy to SCS toTreat Low Back Pain in FBSS
|
N/A | |
Recruiting |
NCT04244669 -
Impact of the SCS With Different Waveforms Over the Quality of Life (SCS-Quality)
|
N/A | |
Completed |
NCT02974101 -
AdaptiveStim Objectifying Subjective Pain Questionnaires
|
N/A | |
Terminated |
NCT01990287 -
SENSE (Subcutaneous and Epidural Neuromodulation System Evaluation) Study
|
N/A | |
Terminated |
NCT01711619 -
SubQStim: A Post-market Study of Subcutaneous Nerve Stimulation in Failed Back Surgery Syndrome (FBSS) Patients
|
N/A |