Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT02302573
Other study ID # PHRI08-FP : Placenta Accreta
Secondary ID
Status Completed
Phase N/A
First received November 14, 2014
Last updated December 5, 2016
Start date May 2009
Est. completion date August 2016

Study information

Verified date December 2016
Source University Hospital, Tours
Contact n/a
Is FDA regulated No
Health authority France: Afssaps - Agence française de sécurité sanitaire des produits de santé (Saint-Denis)
Study type Interventional

Clinical Trial Summary

Abnormally invasive placenta (AIP) is defined as an abnormal placental attachment of a part or the entire chorionic plate with penetration of chorionic villi in the myometrium and absence of the decidua basalis. This anomaly is associated with significant maternal morbidity and mortality as it may result in severe haemorrhage during the post-partum. It has been demonstrated that prenatal diagnosis of AIP is essential to reduce maternal morbidity. In a recent study of Chantraine F. et al. prenatal diagnosis of AIP leads to better outcomes, due to fewer emergency operations and less mass transfusions. Currently, the diagnosis of AIP is based on a combination of conventional B-mode ultrasound and MRI. However, prenatal diagnosis of AIP remains challenging and recent reports demonstrated it is achieved in only thirds of cases.

Contrast enhanced ultrasound (CEUS) is a non-invasive technique based on the detection by ultrasound (US) of gas-filled microbubbles used as perfusion tracers. Intravascular rheological properties of these bubbles are similar to those of red blood cells and they remain entirely within the intravascular space. Previous studies have demonstrated that microbubbles do not transfer into fetal circulation. CEUS has been used for years in many US imaging applications (e.g. liver, kidneys and breast). In obstetrics, despite not yet approved for clinical use, CEUS offers the opportunity to analyze anatomical placental landmarks, improving the contrast between placenta and myometrium. In addition, quantification parameters related to the contrast enhancement have been proposed as objective indicators to estimate blood perfusion rates in the placental intervillous space.

The main objective of this study is to provide pre-clinical evaluation of CEUS for the diagnosis of AIP and to try to determine if AIP are characterised by differences in intervillous blood rheological properties. Conventional CEUS parameters will be: rise time, peak enhancement, wash-in rate, mean transit time and wash-in area under the curve.

As this study is a pre-clinical evaluation, sample size calculation remains subjective and imprecise. For this reason, a sample size of 100 pregnant women to be included in this prospective study has been decided.

The potential impact of this study will be to propose a more reliable tool with both improved sensibility and specificity compared to the combination US/MRI and therefore to reduce the maternal worldwide burden of AIP.


Recruitment information / eligibility

Status Completed
Enrollment 80
Est. completion date August 2016
Est. primary completion date May 2016
Accepts healthy volunteers No
Gender Female
Age group 18 Years and older
Eligibility Inclusion Criteria:

- Pregnant patient having any of the following two conditions:

- Scar uterus (previous cesarean) with placenta previa partly or wholly on the uterine scar

- Placenta praevia and patient aged over 35 years

- Term > 34 weeks of amenorrhea

- More than 18 years old

- Inform consent form signed

- affiliated to medical insurrance

Exclusion Criteria:

- Inability to understand information

- Contraindications to the contrast medium Sonovue:

- Hypersensitivity to hexafluorinated sulphur or any other components of Sonovue

- Recent acute coronary syndrome (within 6 months before the intervention)

- Unstable ischemic heart disease (myocardial infarction being formed or evolving, typical angina of rest in the previous month)

- Significant worsening of cardiac symptoms between the pre anaesthesia consultation and intervention

- Recent intervention (less than 6 months) on coronary arteries or other factor suggesting clinical instability (changes in ECG, changes in clinical or biological parameters)

- Acute heart failure or heart failure stage III or IV

- Severe arrhythmias

- Right-left shunt

- Acute endocarditis

- Valve prothesis

- Severe pulmonary hypertension (pulmonary artery pressure > 90mmHg)

- Systemic hypertension uncontrolled

- Respiratory distress syndrome

Study Design

Intervention Model: Single Group Assignment, Masking: Open Label, Primary Purpose: Diagnostic


Related Conditions & MeSH terms


Intervention

Drug:
contast-enhanced ultrasound with sonovue
contast-enhanced ultrasound with sonovue

Locations

Country Name City State
France CHU La Millétrie ¨Poitiers
France University Hospital of Tours Tours

Sponsors (1)

Lead Sponsor Collaborator
University Hospital, Tours

Country where clinical trial is conducted

France, 

Outcome

Type Measure Description Time frame Safety issue
Primary Conventional contrast enhanced ultrasound parameters for diagnosing placenta accreta up to 9 months after consent No
Secondary depth of infiltration placenta measured by CEUS up to 9 months after consent No
See also
  Status Clinical Trial Phase
Completed NCT04579172 - Conservative Management of Morbidly Adherent Anterior Situated Placenta N/A
Completed NCT04593303 - Internal Iliac Artery Ligation During Management of Placenta Accreta Spectrum N/A
Recruiting NCT03638024 - Cell-free Fetal DNA Concentration in Cases of Abnormal Placental Invasion .
Not yet recruiting NCT06100640 - Paracervical Pouch in Placenta Accreta Spectrum
Completed NCT05979181 - Peripartum Cesarean Hysterectomy for Placenta Percreta
Recruiting NCT04609527 - Management of Placenta Accreta Spectrum Phase 2/Phase 3
Recruiting NCT06185894 - The Role of Using Tourniquet in Decreasing Bleeding in Placenta Accreta Spectrum Cases N/A
Completed NCT04573452 - Galectin-3 and Placenta Accreta
Not yet recruiting NCT03273569 - PDIUC Protocol for Placental Accreta N/A
Completed NCT03707132 - Tourniquet Reduces Blood Loss in Postpartum Hemorrhage During Hysterectomy for Placenta Accreta
Not yet recruiting NCT05104177 - Effectivness of Conservative Techniques in Management of PAS
Completed NCT02806024 - Perioperative Administration of Tranexamic Acid for Placenta Previa and Accreta Study Phase 4
Active, not recruiting NCT02784886 - Cell-free Fetal DNA Circulating in the Maternal Plasma as a Marker for Morbidly Adherent Placenta N/A
Recruiting NCT05070689 - Placenta Accreta Spectrum Disorders: A. Chohan Continuous Squeezing Suture (ACCSS) N/A
Completed NCT05813743 - Detection of Urinary Bladder Wall Involvement in Abnormally Invasive Placenta (AIP) by 3D Ultrasonography N/A
Withdrawn NCT04003428 - Feasibility of HIFU for Management of Placenta Accreta (HIFU-ACCRETA) N/A
Completed NCT04161521 - Conservative Surgical Novel Technique of Placenta Accreta in Menoufia University Hospital N/A
Recruiting NCT05139498 - Conservative Management for PAS Pilot N/A
Not yet recruiting NCT03530475 - Diagnostic Accuracy of Doppler Ultrasound and Role of Uterine Artery Doppler N/A
Recruiting NCT05922397 - Placenta Accreta Spectrum Topographic Classification