Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT04174885
Other study ID # SecondUNI 18.11.2019
Secondary ID
Status Completed
Phase N/A
First received
Last updated
Start date January 1, 2015
Est. completion date January 1, 2019

Study information

Verified date February 2020
Source University of Campania "Luigi Vanvitelli"
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

In this multi centre prospective study authors will evaluate atrial fibrillation (AF) recurrence at 360 days follow-up and calcium handling in patients treated by epicardial thoracoscopic ablation for persistent AF. Indeed, responders patients to epicardial ablation will experience sinus rhythm restoration after the treatment, and will be in sinus rhythm until follow-up end.

However, from October 2014 to June 2016, 27 consecutive patients with persistent AF will be identified and screened for participation in this prospective, multicenter trial at Catholic University of Sacred Heart, Campobasso, at University Study of Molise, Campobasso, at Vecchio Pellegrini Hospital, Naples and at University of Campania "Luigi Vanvitelli", Naples, Italy. All patients will receive an epicardial thoracoscopic pulmonary vein isolation. Before interventions, baseline laboratory studies, B type Natriuretic Peptide (BNP) and serum Sarcoplasmic Endoplasmic Reticulum Calcium ATPase (SERCA) will be evaluated. These markers will be re-evaluated at 12th month of follow-up.

Therefore, study hypothesis will be that successful epicardial ablation might reduce, in responders patients, the SERCA expression. Parallely, a lower serum expression of SERCA in patients with persistent AF might potentially identify a response to an epicardial ablative approach, and an innovative target to improve the response to an epicardial ablative treatment.


Description:

Atrial fibrillation (AF) is most common arrhythmia in the worldwide population, and it is defined as paroxysmal, persistent and/or permanent. Patients with persistent AF might have higher rate of tromboembolic stroke, heart failure events and worse prognosis. Therefore, for patients with persistent AF the sinus rhythm restoration by catheter ablation might be a valid treatment to ameliorate clinical outcomes. On other hand, in patients with persistent AF the catheter ablation by percutaneous approach has a success rate about the 50% at 5 years of follow-up. Indeed, the endocardial ablation cannot determine deeper and extensive trans mural lesions in pulmonary veins and left atrium structure, and this might favor atrial fibrosis and remodeling with consequent persistence of arrhythmic substrate. In this setting, the epicardial AF ablation has been proposed to reach epicardial gaps of the complex arrhythmic atrial substrate, and this might favor sinus rhythm restoration with consequent reduction of the left atrial diameters and volume in patients with persistent AF. Notably, 40% of patients treated by epicardial ablatiion might show an AF recurrence at follow-up. This might be explained by multiple ionic, molecular and cellular alterations favoring AF persistence. In this setting, recently a great interest has been focused to study the calcium handling as cause of abnormal trigger activity and reentry in AF patients, that are both mechanisms implied in the genesis and perpetuation of persistent AF. Intriguingly, patients with persistent AF have an over activity of the Sarcoplasmic Endoplasmic Reticulum (SR) with increased calcium (Ca2+) release. However, in human atrial myocites the Ca2+ overload causes an increased prevalence of spontaneous events and delayed after depolarizations (DADs), (12). Therefore, the SERCA over activity increases the risk of Ca overload and this might be arrhythmogenic (13). Therefore, abnormal Ca2+ signaling and enhanced diastolic SR Ca2+ leak along with cellular DAD-mediated triggered activity might promote AF persistence, than favoring electrical and anatomical reentry. Conversely, the persistence of abnormal Ca2+ signaling and enhanced diastolic SR Ca2+ leak can activate ion channels and trigger Ca2+-dependent signaling pathways, thereby promoting the evolution of atrial remodeling and the progression of AF to more persistent forms. In this setting, authors might speculate that these AF-related alterations in Ca2+ handling and SERCA over activity might contribute to AF persistence after an epicardial ablation. Intriguingly, no data have been reported about the SERCA activity in patients with persistent AF before and after epicardial ablation. Moreover, authors study hypothesis is that a SERCA over expression might be linked to higher rate of failure to an epicardial ablation for patients with persistent AF. Thereafter, in this study authors will evaluate AF recurrences during 1 year of follow-up after epicardial ablation, correlating this clinical outcomes to SERCA protein modifications in patients with sinus rhythm restoration (responders group), vs. atrial fibrillating patients (non responders group) after an epicardial ablative approach.


Recruitment information / eligibility

Status Completed
Enrollment 30
Est. completion date January 1, 2019
Est. primary completion date January 1, 2018
Accepts healthy volunteers No
Gender All
Age group 18 Years to 75 Years
Eligibility Inclusion Criteria:

- persistent AF, both genders, aged >18 years, aged < 75 years.

Exclusion Criteria:

- neoplastic diseases, inflammatory chronic diseases, acute and chronic heart failure.

Study Design


Related Conditions & MeSH terms


Intervention

Procedure:
epicardial ablation
In general anesthesia and left lung ventilation, authors will access the right thorax by three working ports. However, a rigid video thoracoscopic camera with a direct optics will be used. Pericardium will be widely opened anterior to a phrenic nerve and transverse and oblique sinuses were dissected. An insertion of the ablation catheter will be a tricky part of the surgery with the first MW catheter, while no special introducer will be provided. Later RF devices will be equipped with a special flexible introducers, lately also with a magnetic tip and the positioning of the catheter around PVs became much safer and easier. The correct position of catheter will be visualized by trans esophageal echocardiography before the ablation.

Locations

Country Name City State
Italy Celestino Sardu Naples
Italy Raffaele Marfella Naples

Sponsors (1)

Lead Sponsor Collaborator
University of Campania "Luigi Vanvitelli"

Country where clinical trial is conducted

Italy, 

Outcome

Type Measure Description Time frame Safety issue
Primary Atrial fibrillation recurrence. Authors will evaluate the atrial fibrillation recurrence at 12 months of follow-up after epicardial ablation. Atrial fibrillation recurrence will be measured during clinical visits, and by the registration of 12 derivations electrogram (ECG), and ECG Holter. 12 months
See also
  Status Clinical Trial Phase
Completed NCT05970120 - A Study of Intracardiac Ultrasound With the NUVISION NAV Ultrasound Catheter N/A
Recruiting NCT05416086 - iCLAS™ Cryoablation System Post-Market Clinical Follow-up (PMCF) Study N/A
Completed NCT03650556 - Safety and Effectiveness of TactiCath™ Contact Force, Sensor Enabled™ (TactiCath SE) Catheter for Ablation of Drug Refractory, Symptomatic, Persistent Atrial Fibrillation N/A
Recruiting NCT04085731 - Driver-guided Ablation of Persistent Atrial Fibrillatiom
Withdrawn NCT02344394 - Comparison of Hybrid Ablation and Pulmonary Vein Isolation Alone vs Hybrid Ablation With PVI Plus Catheter Ablation N/A
Completed NCT01694563 - ABLATE Post Approval Study - Synergy Ablation Lesions for Non-Paroxysmal Atrial Fibrillation N/A
Terminated NCT01683045 - Efficacy and Safety Study of the Estech COBRA® Surgical System to Treat Patients With a History of Irregular Heart Beats N/A
Active, not recruiting NCT03643224 - DiamondTemp™ System for the Treatment of Persistent Atrial Fibrillation N/A
Withdrawn NCT05093868 - Electrographic Flow Mapping Validation in Patients With Persistent Atrial Fibrillation (EVAL AF) N/A
Completed NCT05152966 - Feasibility Study of the FARAPULSE™ Cardiac Ablation System Plus in the Treatment of Persistent Atrial Fibrillation(PersAFOne II) N/A
Completed NCT05043883 - Automated Assessment of PVI Using a Novel EP Recording System N/A
Completed NCT04022954 - HD Mapping of Atrial Fibrillation in Asia Pacific
Active, not recruiting NCT06124690 - Persistent Atrial Fibrillation Without the Evidence of Low-voltage Areas N/A
Not yet recruiting NCT05454111 - CARTO-Finder Guided Ablation Versus Multiscale Entropy Guided Ablation in Persistent Atrial Fibrillation N/A
Completed NCT06260670 - FLOW EVAL-AF: FLOW Mapping Electrogram VALidation in Patients With Persistent Atrial Fibrillation N/A
Active, not recruiting NCT05077670 - Hybrid Characterization of Driver Sites During Atrial Fibrillation and Sinus Rhythm
Withdrawn NCT03835338 - WATCHMAN for Concomitant Left Atrial Appendage Electrical Isolation and Occlusion to Treat Persistent Atrial Fibrillation Rhythm N/A
Completed NCT02275104 - Multimodal Image Processing Software to Guide Cardiac Ablation Therapy N/A
Not yet recruiting NCT05565183 - Combined Study of ATrial Strain and Voltage by High Density Mapping in Young Patients With Atrial Fibrillation. N/A
Completed NCT02274857 - Randomized Evaluation of Atrial Fibrillation Treatment With Focal Impulse and Rotor Modulation Guided Procedures N/A