Clinical Trials Logo

Clinical Trial Summary

This was a multicenter, prospective, randomized, controlled study. Patients with pelvic fractures (Tile B and c) were recruited from the First Affiliated Hospital of Xi'an Jiaotong University, Xi'an Red Society Hospital and Xi'an 521 hospital, the patients were randomly divided into two groups according to the Order of admission: Experimental Group (intraoperative navigation combined with channel screw technique) and Control Group (open reduction and plate internal fixation) , the difference of operative effect between the two groups was compared by fracture reduction, channel screw position, operative time, fluoroscopy frequency, hospitalization time, hospitalization cost, recovery time and Mayo Score. Use Access 2003 to build a database and store data; use SPSS 21.0. 0 Software for statistical analysis. The entire process required the development of a standardized staff manual, and all were subject to rigorous training and examination in order to participate in the pilot, and the investigation process was supervised by the project leader.


Clinical Trial Description

With the rapid development of the transportation industry and construction industry, pelvic fractures caused by high-energy injuries are increasing year by year, accounting for about 3% -5% of total body fractures. This disease seriously endangers the lives of patients. Once it occurs, the mortality and disability rate are high. Finding the appropriate treatment has been the direction explored by orthopedic surgeons . Undisplaced pelvic fractures can usually be treated conservatively, which has the advantages of low cost and minor trauma, but heavily displaced fractures often require surgery due to the destruction of pelvic stability structures. Conservative treatment cannot achieve functional reduction or even anatomical reduction (Fig. Traditional open reduction and internal fixation with steel plate is the mainstream treatment at present. Still, this method usually requires extensive surgical exposure and massive dissection of soft tissue, which quickly causes some severe complications, including increased infection rate, poor wound healing, increased macrovascular or nerve injury, and heterotopic ossification . At the same time, with the arrival of an aging society, there are more and more pelvic fractures in the elderly in clinical practice, and the treatment faces many challenges. First, the elderly have a poor physical conditions, are primarily associated with medical diseases of varying severity, and have poor tolerance to surgery. Second, with different degrees of decreased bone conditions, some patients with severe osteoporosis have fractures that are difficult to reduce and effectively fix. Their treatment far exceeds the choice between conservative treatment and surgical treatment, requiring multidisciplinary teamwork, including orthopedics, geriatrics, endocrinology, pain, and rehabilitation physiotherapy. The principle of treatment for elderly patients with a pelvic fracture is as follows: while the fixation is as strong as possible, minimally invasive fixation should be adopted as far as possible to reduce the surgical blow and related complications. Therefore, the minimally invasive channel screw technique has become a hot spot in the treatment of pelvic fractures. In recent years, the minimally invasive channel screw technique has been gradually paid attention to by clinicians. It mainly uses a minimally invasive small incision, uses the physiological channel of the pelvis, and uses cannulated screws to fix pelvic and acetabular fractures. This technique provides a reliable and stable fixation of the pelvic acetabulum, which is equivalent to or superior to other existing internal fixation techniques such as plates from a biomechanical point of view, can achieve the effect of open reduction and internal fixation and can avoid complications such as more bleeding and extensive soft tissue dissection caused by open surgery, which will become the most popular method for the treatment of pelvic acetabular fractures. The project group previously tried the channel screw technique for the treatment of pelvic fractures and found that although this method has the advantages of minimally invasive and rapid recovery, it still has the following problems: due to the small incision, it cannot fully expose the visual field and is easy to damage the peripheral blood vessels and nerves. Continuous fluoroscopy under the C-arm is required, and the radiation dose received by patients and physicians is large; for the technical and empirical requirements of physicians, the learning curve of young physicians is high. General anesthesia is used during the operation, which increases the risk of removal of the endotracheal tube if the operation time is high. The development and popularization of intraoperative navigation technology provide the possibility to solve the above problems. Navigation technology is widely used in many fields such as transportation, exploration, military, and exploration. With the continuous development of computer technology, especially the rapid progress of computer graphics technology, a new field of computer-assisted surgery (CAS) has emerged, and computer-assisted navigation system (CANS) is an important part of it. The computer-assisted surgical navigation system is a combination of spatial three-dimensional stereotactic technology, modern imaging diagnostic technology, computer image processing technology, three-dimensional visualization technology, and minimally invasive surgical techniques. It uses signal transmission, transmission, and reception transmitters to calculate the data of each position point through a computer to obtain the required various curves and angles so that the various parameters of the intangible and virtual human body are converted into direct animated images while the position of surgical instruments is displayed in real-time on the surgical images, and the doctor can understand the relationship between the position of instruments and anatomical structures at any time so that the surgical operation becomes safer, more accurate and less invasive. The current application of navigation technology in orthopedics is mainly focused on spinal surgery, which is less used in the field of trauma. Due to the special anatomy of the spine and spinal cord, the high accuracy and safety of surgery are the first considerations. In 1995, Nolte implemented the world's first lumbar pedicle screw internal fixation surgery using a computer-assisted minimally invasive navigation surgical system, which began the use of navigation technology in spinal surgery, and Nolte et al. found that the accuracy of the photoelectric spinal navigation system could reach 1-1.7 mm, and image-guided technology allowed surgeons to clearly understand the spinal anatomy and the pedicle screw needle insertion point and needle insertion direction, and fixed pedicle screws in the correct position of the vertebral body by real-time tracking to improve the surgical accuracy. Channel screw therapy for pelvic fractures is a difficult surgery in the field of trauma. Navigation is used during screw placement. The specific position of the guide needle can be determined according to the real-time three-dimensional picture displayed by the system. The direction of the real guide needle can be corrected by adjusting the direction of the virtual guide needle in time during surgery, providing a safety guarantee for screw placement . In this study, the patients with pelvic fractures (Tile B and C) admitted to the First Affiliated Hospital of Xi'an Jiaotong University, Xi'an Red Cross Hospital, and Xi'an 521 Hospital were used as the cohort study basis, intraoperative navigation combined with channel screw technique was used as the experimental group, and open reduction and internal fixation with steel plate were used as the control group. Through intraoperative evaluation and postoperative follow-up, the surgical effects were compared between the two groups. To explore the significance of intraoperative navigation assisted channel screw technology in the treatment of pelvic fracture, expect that this treatment can reduce the number of fluoroscopies, shorten the operation time, improve postoperative satisfaction of patients, reduce the length of hospital stay and reduce medical costs, and finally this treatment method can be popularized and applied. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05448911
Study type Interventional
Source First Affiliated Hospital Xi'an Jiaotong University
Contact
Status Not yet recruiting
Phase N/A
Start date July 2022
Completion date January 2025

See also
  Status Clinical Trial Phase
Recruiting NCT05606042 - Curvafix® Intramedullary System for Fixation of Pelvic and Acetabular Fractures, A Post Market Evaluation
Not yet recruiting NCT06054165 - Impact of a Clinical Pathway for Pelvic Fragility Fractures N/A
Recruiting NCT04744350 - Conservative or Operative Therapy in Patients With a Fragility Fracture of the Pelvis N/A
Enrolling by invitation NCT03977168 - A Prospective Study of Early Mechanical Stabilization and Bleeding in Disruption of the Pelvic Ring
Completed NCT03475771 - Retrospective Evaluation of Thrombo-embolic Complication in Pelvic Fracture Surgery
Active, not recruiting NCT05354531 - Outcome of the Anterior Subcutaneous Internal Fixator (INFIX) for Pelvic Ring Disruptions N/A
Completed NCT06388915 - A Retrospective Cohort Study of 15 Cases of Pelvic Fractures Complicated by Morel-Lavallee Lesion
Active, not recruiting NCT05836727 - Use of Laparoscopy in the Treatment of Pelvic Ring Ruptures
Recruiting NCT04182776 - Fragility Fractures of the Pelvis (FFP)
Not yet recruiting NCT03944174 - Single Trans-sacral Screw Versus Two Iliosacral Screws
Completed NCT02855060 - Pre-hospital Advanced Therapies for Control of Hemorrhage - Pelvis N/A
Recruiting NCT05367505 - Titanium Fusion Implant in Combination With Trans-iliac Screws for Insufficiency Fractures of the Pelvis N/A
Completed NCT04217499 - Pelvic Ring Fractures: New Analysis Method and Treatment Decision Algorithm
Terminated NCT00594906 - Use of Teriparatide to Accelerate Fracture Healing N/A
Completed NCT04303442 - Corona Mortis in Patients Undergoing TEP for Inguinal Hernia
Enrolling by invitation NCT05712850 - Clinical Outcome and Fusion Results Using the SiJoin® Transfixing Sacroiliac Fusion Device
Recruiting NCT04937868 - Developing a Decision Instrument to Guide Abdominal-pelvic CT Imaging of Blunt Trauma Patients
Withdrawn NCT04764864 - Pelvic Fractures in Polytraumatized Patients With Hemodynamic Instability: Angioembolization vs Preperitoneal Packing N/A
Recruiting NCT04615104 - Pelvic and Acetabular Fracture: A Prospective Observational Study
Completed NCT03195179 - Primary Urethral Realignment Versus Suprapubic Cystostomy After Pelvic Fracture Urethral Injury