Heart Failure Clinical Trial
Official title:
His Pacing in Patients Without Need for Cardiac Resynchronization - Clinical Feasibility and Cardiac Electrical Activation
This study will examine the clinical feasibility of His pacing in patients with expected high demand for ventricular pacing and no established indication for cardiac resynchronization therapy. Secondarily, examine differences in electrical and mechanical cardiac activation between traditional pacing and His pacing.
After being informed about the study and potential risks, all eligible patients giving written consent will be included. The study is a clinical single-center interventional study. The patients (n = 25) need to have an expected high demand for ventricular pacing and no established class I indication for cardiac resynchronization therapy. They will receive a pacemaker implant with a traditional right ventricular pacing lead and an additional His pacing lead in a basal high septal position at the level of the proximal electrical conduction system (His). An atrial lead is implanted if dual chamber pacing is needed. All leads are connected to a biventricular pacemaker with the His lead in the LV port. Postoperatively, the baseline examinations will include: transthoracic echocardiography, 12-lead ECG with a 3D photography of the chest wall to document ECG electrode location, and a contrast-enhanced cardiac CT scan. The echocardiography and ECG will be performed during traditional right ventricular pacing only and His pacing only. His pacing will be used as the permanent programming of choice if feasible during follow up. The CT scan is used for documenting the final positions of the pacing leads and to create a patient-specific 3D model of the cardiac electrical activation using a software which enables merging of a CT scan and ECG and a CT chest photography. During follow up (1-3 and 12 months), transthoracic echocardiography, 12-lead ECG and 3D chest photography are repeated for assessment of mechanical and electrical function during pacing. The performance of all implanted pacing lead will be evaluated at each follow up visit. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT05650307 -
CV Imaging of Metabolic Interventions
|
||
Recruiting |
NCT05654272 -
Development of CIRC Technologies
|
||
Recruiting |
NCT05196659 -
Collaborative Quality Improvement (C-QIP) Study
|
N/A | |
Active, not recruiting |
NCT05896904 -
Clinical Comparison of Patients With Transthyretin Cardiac Amyloidosis and Patients With Heart Failure With Reduced Ejection Fraction
|
N/A | |
Completed |
NCT05077293 -
Building Electronic Tools To Enhance and Reinforce Cardiovascular Recommendations - Heart Failure
|
||
Recruiting |
NCT05631275 -
The Role of Bioimpedance Analysis in Patients With Chronic Heart Failure and Systolic Ventricular Dysfunction
|
||
Enrolling by invitation |
NCT05564572 -
Randomized Implementation of Routine Patient-Reported Health Status Assessment Among Heart Failure Patients in Stanford Cardiology
|
N/A | |
Enrolling by invitation |
NCT05009706 -
Self-care in Older Frail Persons With Heart Failure Intervention
|
N/A | |
Recruiting |
NCT04177199 -
What is the Workload Burden Associated With Using the Triage HF+ Care Pathway?
|
||
Terminated |
NCT03615469 -
Building Strength Through Rehabilitation for Heart Failure Patients (BISTRO-STUDY)
|
N/A | |
Recruiting |
NCT06340048 -
Epicardial Injection of hiPSC-CMs to Treat Severe Chronic Ischemic Heart Failure
|
Phase 1/Phase 2 | |
Recruiting |
NCT05679713 -
Next-generation, Integrative, and Personalized Risk Assessment to Prevent Recurrent Heart Failure Events: the ORACLE Study
|
||
Completed |
NCT04254328 -
The Effectiveness of Nintendo Wii Fit and Inspiratory Muscle Training in Older Patients With Heart Failure
|
N/A | |
Completed |
NCT03549169 -
Decision Making for the Management the Symptoms in Adults of Heart Failure
|
N/A | |
Recruiting |
NCT05572814 -
Transform: Teaching, Technology, and Teams
|
N/A | |
Enrolling by invitation |
NCT05538611 -
Effect Evaluation of Chain Quality Control Management on Patients With Heart Failure
|
||
Recruiting |
NCT04262830 -
Cancer Therapy Effects on the Heart
|
||
Completed |
NCT06026683 -
Conduction System Stimulation to Avoid Left Ventricle Dysfunction
|
N/A | |
Withdrawn |
NCT03091998 -
Subcu Administration of CD-NP in Heart Failure Patients With Left Ventricular Assist Device Support
|
Phase 1 | |
Recruiting |
NCT05564689 -
Absolute Coronary Flow in Patients With Heart Failure With Reduced Ejection Fraction and Left Bundle Branch Block With Cardiac Resynchronization Therapy
|