Clinical Trials Logo

Clinical Trial Summary

The investigators are examining a scientific principle called the Frank Starling Mechanism and how it relates to Cardiac Resynchronisation Therapy (CRT), a form of pacemaker therapy used in the treatment of heart failure. The Frank Starling Mechanism is an established biological principle. The law states that the stroke volume of the heart increases in response to an increase in the volume of blood in the ventricles, before contraction, when all other factors remain constant. In other words, the law states that the more blood enters the heart, the more blood is pumped out of the heart with any given beat. There is some evidence that in some patients with chronic heart conditions, the Frank Starling Mechanism is LESS EFFECTIVE, meaning that the heart is less able to cope with a reduction in heart pumping function over time. There is also evidence that treatment with CRT may IMPROVE the Frank Starling Mechanism - evidence for this has been shown in dog and mice hearts, however, has never been shown in humans. The investigators aim to conduct a study where subjects undergo an ultrasound scan of the heart (echocardiogram) whilst the participants pacemaker settings are temporarily changed. This allows the investigators to measure the pumping function of the heart as more blood enters the heart. The investigators will perform this test on 20 participants before and after CRT, as well as 20 participants who have pacemakers, but no heart failure. This study aims to test 3 hypotheses. 1. In participants with pacemakers, a REDUCED Frank Starling Mechanism predicts which participants go on to develop heart failure. 2. Treatment with CRT IMPROVES the Frank Starling Mechanism in participants with pacemakers and heart failure. 3. The degree of improvement of the Frank Starling Mechanism after treatment with CRT predicts which participants will respond to this treatment.


Clinical Trial Description

The primary research investigation in this study is a non-invasive test of the Frank Starling mechanism, which involves performing a transthoracic echocardiogram (ultrasound scan of the heart) whilst temporarily changing pacemaker settings to mimic conditions such as faster heart rates or increased blood flow to the heart. Measurements taken from the echocardiogram during these changes in pacemaker settings will be used to determine the effectiveness of the heart's Starling Mechanism. This test will last between 20-40 minutes. No special preparation is needed and participants will be able to go home immediately afterwards. Pacemaker settings will be returned to normal once the test is completed. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05993585
Study type Interventional
Source Guy's and St Thomas' NHS Foundation Trust
Contact Sandra N Howell/Dr, Med State Exam, MSc, MSc
Phone 44 020 7188 9257
Email sandra.howell@kcl.ac.uk
Status Recruiting
Phase N/A
Start date January 15, 2024
Completion date June 2, 2025

See also
  Status Clinical Trial Phase
Recruiting NCT04870424 - Colchicine for Patients With Aortic Stenosis Undergoing Transcatheter Aortic Valve Replacement Phase 3
Completed NCT02548819 - University Hospital Cardiac Device MR Registry: The Safety of MR Imaging in Patients With Implanted Cardiac Devices N/A
Recruiting NCT03636230 - Remote Patient Management of CIEDs - Brady Devices N/A
Terminated NCT03859167 - Study of the Loss of AV Synchrony at Maximum Exercise
Completed NCT00832988 - CONFIRM - Comparison of in Office Interrogation Versus Remote Measurements
Completed NCT00294034 - VIBRANT Registry: Value of Information Based From Pacemaker Recordings and New Technologies N/A
Recruiting NCT05623527 - Acute Cerebrovascular Events Secondary to Patients Receiving Cardiac Electronic Implants
Completed NCT03847298 - Evaluation of Physical Fitness and Physical Activity Levels of Pediatric Arrhythmia Patients With Pacemaker
Completed NCT03843242 - Evaluation of Ventricular Pacing Suppression Algorithms in Dual Chamber Pacemaker N/A
Active, not recruiting NCT01138670 - Complications Following Pacemaker or Implantable Defibrillator Cardioverter (ICD) Implantation in Denmark N/A
Completed NCT00307073 - Adapta Pacing System Clinical Study N/A
Completed NCT04958369 - Ultrasound-guided Axillary Versus Conventional Cephalic Venous Access for Implantation of Cardiac Devices N/A
Completed NCT00631709 - REmote MOnitoring Transmission Evaluation of IPGs Phase 4
Completed NCT01459874 - Evaluation of an Organizational Model for Remote Monitoring of Pacemaker and Implantable Cardioverter Defibrillator Recipients N/A
Recruiting NCT06356207 - Syncope-Asystole Latency Time in Tilt Table Test: The SALT-TILT Study
Not yet recruiting NCT06299514 - RAFT-P&A Randomized Control Trial N/A
Completed NCT03052829 - Physical Activity and Pacemaker Study N/A
Completed NCT00491777 - Correlation Research Study: IQ2, NcIQ and IQ101 Phase 1
Active, not recruiting NCT05361681 - EMI and CIED: Is High Power Charging of Battery Electric Car Safe? N/A
Recruiting NCT04201015 - Optimising Pacing for Contractility 2 Phase 2/Phase 3