View clinical trials related to Pacemaker.
Filter by:Cardiac Implantable Electronic Devices (CIEDs) such as pacemakers and implantable cardioverter defibrillators need to be regularly and systematically interrogated and reprogrammed to ensure proper functioning. While remote monitoring allows for partial interrogation at a remote location, full CIED check-up and reprogramming is only possible when the patient visits a cardiologist capable of performing device programming. This can be challenging for patients and may cause unnecessary delays, particularly in settings of limited resources, enforced physical distancing, and quarantines. The aim of this study is to evaluate our previously validated remote programming solution (REACT study, NCT05366660) in outpatient device clinics which are close to the patient's home but remote from the CIED expert.
Determine the consequences of COVID-19 pandemic on routine targeted surgeries. Five surgical procedures were considered : cataract surgery, hip and knee arthoplasties, coronary revascularisation by angioplasty and definitive cardiac stimulation. The objective of the study is to quantify changes of these procedures in 2020 and in 2021 (up to June) compared to 2019 taking into account their annual evolution and according to the type of operation (primary or reoperation/revision) and emergency status, if applicable.
The investigators assessed whether short-term cardiac rehabilitation following pacemaker implantation was enough to improve both physical function and quality of life.
The implantation of cardiac electronic devices is a common procedure in the Electrophysiology Laboratory. The most commonly used venous access sites are the cephalic, the axillary and the subclavian vein. Studies comparing these options have been conducted in the past. Axillary venous access can be achieved either through axillary vein angiography or by ultrasound guidance. Nevertheless, appropriate training is required for the ultrasound-guided axillary puncture technique-as well as for the cephalic vein cutdown technique. Data from randomized trials regarding direct comparison of the two methods in terms of efficacy and safety are very limited. The purpose of the study is the comparison of the efficacy and safety of the ultrasound-guided axillary venous access technique versus the cephalic venous access using the cut-down technique in patients requiring intravenous cardiac device (single-chamber/dual-chamber pacemaker/defibrillator) implantation.
Recent exploratory studies suggest that pacemaker patients with diastolic dysfunction (DD) or heart failure with preserved ejection fraction (HFpEF) may benefit from a higher backup heart rate (HR) setting than the factory setting of 60 beats per minute (bpm). In this prospective double-blinded randomized controlled study, pacemaker patients with DD or overt HFpEF and either 1) intrinsic ventricular conduction or 2) conduction system or biventricular pacing will be enrolled and randomized to either a personalized lower HR setting (myPACE group, based on a height-based HR algorithm) or to the standard 60bpm backup setting (control group) for 1 year.
Venous access is a fundamental step in lead insertion for endovenous cardiac implantable electronic devices (CIED). Cephalic vein cutdown is the most widely used technique in Europe. Ultrasound-guided axillary vein access is a promising alternative but there is a lack of clinical evidence supporting this technique. The purpose of this study is to compare the efficacy and safety of ultrasound-guided axillary vein access versus cephalic venous cutdown for implantation of endovenous CIED. Half of patients is implanted using an ultrasound-guided axillary vein puncture. The other half is implanted using a cephalic vein cutdown. After venous access is achieved, implantation procedure is identical in the two arms.
This is a prospective, single-site, non-randomized, acute feasibility clinical study. The purpose of this study is to explore the electrocardiogram (ECG) characteristics of simultaneous stimulation of right and left bundle branches area.
The aim of this study was to evaluate physical fitness and physical activity levels of pediatric arrhythmia patients with pacemaker compared with their healthy peers.
The recent study using IRSplus and VpS algorithm from Biotronik pacemaker showed the significant reduction in ventricular pacing to less than 3%. The purpose of this study is to evaluate the efficacy of IRSplus and VpS algorithm in reducing ventricular pacing compared with conventional DDD pacing with a fixed AV delay.
It is well-known that not only peripheral muscles, but also respiratory muscles muscle weakness and deconditioning play an important role in low exercise capacity of patients with Heart Failure (HF). Exercise training has been shown to improve exercise tolerance and quality of life in patients with heart disease. However, hearth failure patients with pacemaker such as implantable cardioverter defibrillators (ICDs), cardiac resynchronization pacemakers or defibrillators (CRT-P or CRT-D) have additional specific issues when performing exercise. No study investigated the effects of different inspiratory muscle training protocols. For this reason, we aimed to investigate the effects of inspiratory muscle training on outcomes in hearth failure patients with pacemaker