Clinical Trial Summary

Main objective: Show the superiority of tonotopy based fitting strategy compared to default fitting strategy on the perception speech in noise. Secondary objectives: Show the superiority of tonotopy based fitting strategy compared to default fitting strategy on the perception of musical elements (contour test). Show the non inferiority of tonotopy based fitting strategy compared to default fitting strategy on the perception of speech elements in quiet. Show the superiority of tonotopy based fitting strategy compared to default fitting strategy on the qualitative preference for the listening of musical pieces.


Description:

Introduction: Cochlear implantation allows the rehabilitation of profound bilateral deafness, restoring speech perception and verbal communication when the traditional hearing aid no longer provides satisfactory hearing gain (Nimmons et al.). A cochlear implant includes an electrode array and its functioning is based on the principle of cochlear tonotopy: each electrode encodes a frequency spectrum according to its position in the cochlea (high frequencies are assigned to the basal electrodes and low frequencies to the apical electrodes). The cochlear implant thus breaks down the frequency spectrum into a number of frequency bands via bandpass filters corresponding to the number of electrodes in the implant. During the fitting these bands can be modified by the audiologist. The fitting software developed by the manufacturers proposed a default fitting with a lower limit between 100 and 250 Hz according to the brands and an upper limit of about 8500 Hz. The frequency bands assigned to each electrode follow a logarithmic scale with the high frequencies for the basal electrodes and the low frequencies for the apical electrodes. This distribution takes into account the number of active electrodes but does not take into account the anatomy and the natural cochlear tonotopy specific to each patient. Several studies have analyzed the anatomical variations of the cochlear dimensions: size of the cochlea and the ratio between the contact surfaces of the electrodes with the cochlea are variable from one patient to another (Stakhovskaya O et al., P. Pelliccia et al.). The insertion depth during surgery is also variable due to parameters related to the patients as well as to the operator, which seems to impact the understanding of speech in noise (Deep electrode insertion and sound coding in cochlear implants - Ingeborg Hochmair et al.). Mathematical algorithms have recently been developed to estimate the cochlear tonotopy of each patient from a CT scan assessment (Jiam et al., Sridhar et al.). CT imaging of the implanted ear combined with 3D reconstruction software, provides cochlear length measurements (Cochlear length determination using Cone Beam Computed Tomography in a clinical setting - Würfel et al .) Using this approach it is possible to measure the position of each electrode relative to the cochlear apex. These measurements are applied to the modified Greenwood equation to obtain the tonotopic frequency for each electrode and to determine for each patient a fitting based on the tonotopy of each electrode. Main objective: Show the superiority of tonotopy based fitting strategy compared to default fitting strategy on the perception speech in noise. Secondary objectives: Show the superiority of tonotopy based fitting strategy compared to default fitting strategy on the perception of musical elements (contour test). Show the non inferiority of tonotopy based fitting strategy compared to default fitting strategy on the perception of speech elements in quiet. Show the superiority of tonotopy based fitting strategy compared to default fitting strategy on the qualitative preference for the listening of musical pieces. Plan of the study: It is a prospective open monocentric randomized crossover study: measures will be done on the patient at 6 weeks and 12 weeks post-activation.


Recruitment information / eligibility

Status Completed
Enrollment 26
Est. completion date September 30, 2021
Est. primary completion date August 31, 2021
Accepts healthy volunteers No
Gender All
Age group 18 Years and older
Eligibility Inclusion Criteria: - Adult patient (>= 18 years old) speaking French - Patient who fulfils the criteria for cochlear implantation Exclusion Criteria: - retro-cochlear pathology: auditory neuropathy, vestibular schwannoma - patient with residual hearing < 60 dB HL at 250 Hz and < 80 dB HL at 500 Hz

Study Design


Related Conditions & MeSH terms


Intervention

Device:
tonotopy based fitting then default fitting
Cochlear implant with default fitting then tonotopy based fitting
default fitting then tonotopy based fitting
Cochlear implant with tonotopy based fitting then default fitting

Locations

Country Name City State
France CHU Rennes Rennes

Sponsors (1)

Lead Sponsor Collaborator
MED-EL Elektromedizinische Geräte GesmbH

Country where clinical trial is conducted

France, 

Outcome

Type Measure Description Time frame Safety issue
Primary speech recognition in noise The speech recognition in noise is evaluated with syllabic list of 40 phonemes. The patient has to recognize 20 syllables. The phonemes are scored: each good answer is scored 1 yielding a total between 0 and 1 (or 0% and 100%). Signal-noise-ratios of 9, 6, 3 and 0 dB will be tested with speech at 65 dB SPL. at 6 weeks post-activation
Primary speech recognition in noise The speech recognition in noise is evaluated with syllabic list of 40 phonemes. The patient has to recognize 20 syllables. The phonemes are scored: each good answer is scored 1 yielding a total between 0 and 1 (or 0% and 100%). Signal-noise-ratios of 9, 6, 3 and 0 dB will be tested with speech at 65 dB SPL. at 12 weeks post-activation
Secondary speech recognition in quiet The speech recognition in quiet is evaluated with syllabic list of 40 phonemes. The patient has to recognize 20 syllables. The phonemes are scored: each good answer is scored 1 yielding a total between 0 and 1 (or 0% and 100%). at 6 weeks post-activation
Secondary speech recognition in quiet The speech recognition in quiet is evaluated with syllabic list of 40 phonemes. The patient has to recognize 20 syllables. The phonemes are scored: each good answer is scored 1 yielding a total between 0 and 1 (or 0% and 100%). at 12 weeks post-activation
Secondary Melodic contour test The test stimuli of the melodic contour test (Galvin et al. 2007) are melodic contours composed of 5 notes of equal duration whose frequencies correspond to musical intervals. Nine distinct musical patterns have to be identified by the patient. Each good answer is scored 1 yielding a total between 0 and 1 (or 0% and 100%). at 6 weeks post-activation
Secondary Melodic contour test The test stimuli of the melodic contour test (Galvin et al. 2007) are melodic contours composed of 5 notes of equal duration whose frequencies correspond to musical intervals. Nine distinct musical patterns have to be identified by the patient. Each good answer is scored 1 yielding a total between 0 and 1 (or 0% and 100%). at 12 weeks post-activation
Secondary Qualitative measure of music The Gabrielsson scale (1988) is used to evaluate perceived sound quality as a multidimensional phenomenon, that is composed of a number of separate perceptual dimensions. Eight perceptual dimensions are evaluated: clarity, fullness, brightness vs dullness, hardness/sharpness vs softness, spaciousness, nearness, extraneous sound, loudness.
Visual analog scales (VAS) are used for each dimension and the patient has to score the dimension on a 10 cm VAS (between 0 to 10).
at 6 weeks post-activation
Secondary Qualitative measure of music The Gabrielsson scale (1988) is used to evaluate perceived sound quality as a multidimensional phenomenon, that is composed of a number of separate perceptual dimensions. Eight perceptual dimensions are evaluated: clarity, fullness, brightness vs dullness, hardness/sharpness vs softness, spaciousness, nearness, extraneous sound, loudness.
Visual analog scales (VAS) are used for each dimension and the patient has to score the dimension on a 10 cm VAS (between 0 to 10).
at 12 weeks post-activation
See also
  Status Clinical Trial Phase
Recruiting NCT05621798 - Quantifying the Benefits and Cost-effectiveness of Real-Ear Measurements (REM) for Hearing Aid Fitting N/A
Completed NCT04571333 - Feasibility of the Mi2000 Totally Implantable Cochlear Implant in Severely to Profoundly Deaf Adults. N/A
Recruiting NCT05821959 - Gene Therapy Trial for Otoferlin Gene-mediated Hearing Loss Phase 1/Phase 2
Completed NCT04777565 - Study of a Minimally Invasive Cochlear Access for Cochlear Implantation Via a Robotic Procedure N/A
Not yet recruiting NCT05154188 - Post Approval Study to Assure the ContInued saFety and effectIveness of Neuro Cochlear Implant System in Adult Users
Completed NCT03304106 - Clinical Investigation of New CI Delivery Models in an Adult Nucleus CI Population N/A
Recruiting NCT05898659 - Comparison in New Cochlear Implanted Subjects of a Tonotopy-based Bimodal Fitting With or Without Synchronization N/A
Recruiting NCT05955469 - Comparison in New Cochlear Implanted Subjects of a Tonotopy-based Bimodal Fitting and a Conventional Fitting N/A
Completed NCT04145661 - Non-linear Frequency Compared to Conventional Processing in Patients With and Without Cochlear Dead Regions. N/A
Recruiting NCT05402813 - Natural History in Children up to 10 Years With Moderate to Profound Hearing Loss Due to Mutations in GJB2 / OTOF Genes
Not yet recruiting NCT06354010 - Cross-sectional and Prospective Study to Characterize Early-onset Presbycusis
Completed NCT02755935 - CI532 - Early Experience Study N/A
Completed NCT04469946 - Hearing Aid Noise Reduction in Pediatric Users Pilot Study (Oticon Pilot Study) N/A
Recruiting NCT05369598 - Audiological and Quality of Life Outcomes of Anatomy Based Fitting in Patients Implanted by Robot Assisted Cochlear Implant Surgery (RACIS) N/A
Recruiting NCT05572073 - Otoferlin Gene-mediated Hearing Loss Natural History Study
Recruiting NCT04591093 - Auditory Performances With Different Stimulation Depths in Cochlear Implanted Subjects Using a Fine Structure Strategy N/A
Completed NCT03993899 - Study of Quality Perception on Music in New Cochlear Implanted Subjects Using or Not a Fine Structure Strategy N/A
Withdrawn NCT03694704 - Study of Auditory Performance on Prosodic Tests in Cochlear Implanted Subjects Using a Fine Structure Strategy N/A
Terminated NCT03904420 - An Evidence Based Delivery Model of Care for Newly Implanted Adult CI Recipients N/A
Recruiting NCT05230498 - Study of Sound and Speech Perception in New Cochlear Implanted Subjects Using or Not an Anatomy-based Fitting N/A