Clinical Trials Logo

Clinical Trial Summary

Both premature and delayed extubation prolong the duration of mechanical ventilation and the intensive care unit (ICU) length of stay and increase morbidity and mortality. Therefore, accurate prediction of postextubation distress and the early diagnosis of the causes responsible for failure of a trial of pressure support ventilation are of paramount importance to improve the outcome of mechanically ventilated patients in the ICU. This observational study is designed to test the ability of cardiac and diaphragm function assessed by bedside ultrasound to predict extubation failure within 48 h and re-intubation within 1 week after extubation.


Clinical Trial Description

Weaning from mechanical ventilation is the process of gradual ventilatory support reduction to the patient subjected to mechanical ventilation for more than 24 hours. Determining the correct time to extubate mechanically ventilated patients is a crucial issue in the critical care practice. Spontaneous breathing trial (SBT) is recommended to predict weaning outcome. However, 13% to 26% of patients who are extubated following a successful SBT need to be reintubated within 48 hours. Traditional indicators, such as respiratory rate (RR), minute ventilation, tidal volume (VT), and the rapid shallow breathing index (RSBI), can reflect patients' integral conditions, but none has shown great prognostic accuracy for weaning failure. Although there are several causes of weaning failure, cardiac function deterioration during the weaning process combined with acute pulmonary edema is considered the leading cause of weaning failure. The transition from positive to negative thoracic pressure increases venous return and left ventricular afterload, decreases left ventricular compliance and may induce cardiac ischemia. All of these factors tend to increase ventricular filling pressures and may consequently lead to weaning-induced pulmonary edema. The efficacy of echocardiography for predicting weaning failure has been reported, however there is debate over the predictive value of echocardiography in this setting continues due to differences in weaning technique and outcome evaluation. The diaphragm is the principal respiratory muscle. With an excursion of 1 to 2 cm, it provides nearly 75% of the resting pulmonary ventilation, while during the forced breathing, its amplitude is up to 7 to 11 cm. However, the diaphragm is vulnerable to damage from hypotension, hypoxia, and sepsis, which are very common in critically ill patients. While in surgical patients, diaphragm dysfunction is often caused by acute insults such as trauma or surgical procedures. In addition, mechanical ventilation itself can decrease the force of the diaphragm and induce diaphragmatic dysfunction, named as ventilator-induced diaphragmatic dysfunction. Many studies have shown that Diaphragm dysfunction is responsible for a number of pulmonary complications, including atelectasis and pneumonia, which are risk factors for extubation failure. and might lead to weaning failure and long-term mechanical ventilation. Some studies have reported that diaphragmatic excursion (DE) or and diaphragmatic thickening fraction (DTF) could predict extubation failure. Although transthoracic echocardiography and diaphragm ultrasound have been confirmed in independently assessing extubation outcomes, few studies have shown their different roles in the weaning process until now. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04703387
Study type Observational
Source Tanta University
Contact
Status Completed
Phase
Start date August 1, 2020
Completion date December 31, 2022

See also
  Status Clinical Trial Phase
Recruiting NCT05030337 - Optimising Ventilation in Preterms With Closed-loop Oxygen Control N/A
Completed NCT05144607 - Impact of Inspiratory Muscle Pressure Curves on the Ability of Professionals to Identify Patient-ventilator Asynchronies N/A
Recruiting NCT03697785 - Weaning Algorithm for Mechanical VEntilation N/A
Completed NCT05084976 - Parental Perception of COVID-19 Vaccine in Technology Dependent Patients
Active, not recruiting NCT05886387 - a Bayesian Analysis of Three Randomised Clinical Trials of Intraoperative Ventilation
Completed NCT04429399 - Lowering PEEP: Weaning From High PEEP Setting N/A
Completed NCT02249039 - Intravenous Clonidine for Sedation in Infants and Children Who Are Mechanically Ventilated - Dosing Finding Study Phase 1
Recruiting NCT02071524 - Evaluation of the Effects of Fluid Therapy on Respiratory Mechanics N/A
Completed NCT01114022 - Prevention Inhalation of Bacterial by Using Endotracheal Tube Balloon Polyvinyl Chloride or Polyurethane N/A
Completed NCT00893763 - Strategies To Prevent Pneumonia 2 (SToPP2) Phase 2
Terminated NCT05056103 - Automated Secretion Removal in ICU Patients N/A
Active, not recruiting NCT04558476 - Efficacy of CONvalescent Plasma in Patients With COVID-19 Treated With Mechanical Ventilation Phase 2
Recruiting NCT05295186 - PAV Trial During SBT Trial
Active, not recruiting NCT05370248 - The Effect of 6 ml/kg vs 10 ml/kg Tidal Volume on Diaphragm Dysfunction in Critically Mechanically Ventilated Patient N/A
Completed NCT04589910 - Measuring Thickness of the Normal Diaphragm in Children Via Ultrasound. N/A
Completed NCT04818164 - Prone Position Improves End-Expiratory Lung Volumes in COVID-19 Acute Respiratory Distress Syndrome
Completed NCT04193254 - LPP , MP and DP:Relation With Mortality and SOFA in Mechanically Ventilated Patients in ER, Ward and ICU
Completed NCT06332768 - NIV Versus HFO Versus Standard Therapy Immediately After Weaning From Mechanical Ventilation in ARDS Patients N/A
Not yet recruiting NCT03259854 - Non Invasive Mechanical Ventilation VERSUS Oxygen MASK N/A
Not yet recruiting NCT03245684 - Assisted or Controlled Ventilation in Ards (Ascovent) N/A