Clinical Trials Logo

Clinical Trial Summary

Over the last decades, research in cardiopulmonary resuscitation was primarily focused on uninterrupted chest compressions to restore sufficient circulation. Ventilation during ongoing chest compressions was regarded as potentially deleterious and thus not given any major scientific focus. Current guidelines advise that ventilation be monitored by end-tidal CO2 and emphasize that hyperventilation be avoided. Recent findings from arterial blood gas analyses showed high levels of arterial pCO2, resulting in a frequent occurrence of hypercapnic acidosis, which may be caused by iatrogenic hypoventilation. Ventilation during ongoing chest compressions can be hard to achieve, as nearly every breath may be terminated by simultaneous chest compressions. In case of bag ventilation the applied tidal volumes have not yet been measured und mechanical ventilators so far were not able to ventilate during chest compressions, because pressure limit settings induced termination of inspiration. The aim of this study is to provide patients with the best possible ventilation, even under ongoing chest compressions. Patients are ventilated with a new turbine-driven ventilator (Monnal T60, Air Liquide, France), which can deliver adequate tidal volumes within a very short inspiratory phase due to the inspiratory flow of > 200l/min. Thus, in deviation from the current recommendations, the ventilation rate can be doubled to 20/min, so that inspiration coincides with cardiac massage less often. The study compares effective ventilation volumes applied by two regimes, 10 breaths/min and 20/min.


Clinical Trial Description

Restoration of circulation is undoubtedly the basis of success in cardiopulmonary resuscitation (CPR). Current guidelines on CPR require that hyperventilation be avoided during CPR. Blood gas analysis results from the "BABICA trial" demonstrate that more than 90% of patients have highly elevated levels of pCO2 and are acidotic, mainly due to hypercapnia. No hyperventilated or alkalotic patients were found during CPR. Furthermore, higher pO2 values were found to be associated with improved outcomes. Current recommendations to limit ventilation frequency to 10/min was also critically questioned in a recent study from Belgium, which did not show any positive effect of low respiration rate compared to higher ones, cut-off 10/min. There are currently no clinical trials addressing optimal tidal volumes or minute volumes during CPR. A major obstacle to continuous measurement of respiratory minute volumes during CPR are ongoing chest compressions. In a retrospective study in which respiratory volumes were derived from bioimpedance curves, better outcomes were found in the group of more frequent ventilations. Common machine ventilators display set values, while expiratory volumes are averaged and may be overlaid by volume shifts of cardiac massage. In a recent study, investigators analyzed flow curves, where each breath can be evaluated individually and volumes can be derived correctly using dedicated software. We were able to test this method on a comparative study of three ventilators study on anatomical cadavers. This study aims to detect whether a higher rate of ventilation using a turbine driven ventilator is able to provide higher breathing volumes during ongoing chest compressions in individuals suffering from out-of-hospital cardiac arrest (OHCA). Higher ventilation and oxygenation parameters as well as optimized acid-base-balance and increased rates of ROSC are expected. Patient care (chest compressions, venous access, endotracheal intubation, application of drugs, defibrillation if necessary) is conducted according to current recommendation for Advanced Life Support (ALS) as issued by the European Resuscitation Council (ERC). Ventilation is performed at one of two patterns: the control group is ventilated at 10 breaths per minute, the intervention group is ventilated at 20 breaths per minute. Patterns are alternating according to calendar week. After successful endotracheal intubation mechanical ventilation is carried out using a turbine-driven ventilator (Monnal T60, AirLiquide, France). Ventilator settings are pre-set: respiratory frequency is set at 10/min or 20/min (see above), other ventilator parameters remain identical: Positive End-Expiratory Pressure (PEEP) 0 mmHg, FiO2 1,0, tidal volume 6ml/kg ideal body weight [men: 50+(0.91x(body length-152.4)), women: 45+(0.91y(body length-152.4))]. These calculations can be performed on the ventilator itself by entering patients' age, height and gender. Chest compressions are carried out without interruptions and without considerations regarding the respiratory cycle. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04657393
Study type Interventional
Source Medical University of Graz
Contact
Status Terminated
Phase N/A
Start date June 1, 2019
Completion date November 30, 2021

See also
  Status Clinical Trial Phase
Completed NCT02580526 - Comparison of Mask Ventilation Techniques in Patients Requiring General Anesthesia N/A
Completed NCT02627001 - Nu-Mask Intraoral Airway Device Versus Conventional Bag Valve Mask Ventilation Crossover Trial Phase 4
Recruiting NCT01825473 - Study of Erythromycin in GER-Associated Apnea of the Newborn N/A
Completed NCT02103777 - High Versus Low Dose of Caffeine for Apnea of Prematurity Phase 3
Completed NCT00950287 - Detection of Neonatal Bradycardia N/A
Recruiting NCT00382876 - Identifying the Relative Change in Ventilation in Newborns With Placement in Car Bed or Car Seat N/A
Completed NCT00369759 - An Epidemiological Study to Evaluate the RSV-Associated Lower Respiratory Track in Infections in Infants N/A
Completed NCT04084535 - Effects of High Intensity Interval Training (HIIT) vs. Inspiratory Muscle Training on the Recovery After a Maximal Apnea. N/A
Recruiting NCT02968797 - Clinical Comparative Study to Validate Performance of SafeSed Prototype Monitoring Endoscopy Under Sedation
Completed NCT02554110 - Peripheral Nerve Stimulation to Reduce Hypoxic Events N/A
Not yet recruiting NCT04366414 - Breathing Protocol in Breath-hold Divers N/A
Completed NCT05124093 - The Effect of High-flow Nasal Oxygen Flow Rate on Gas Exchange During Apnoea N/A
Recruiting NCT01994785 - Use of Capnography in EGD and Colonoscopy With Moderate Sedation. N/A
Completed NCT01435486 - Caffeine Citrate for the Treatment of Apnea Associated With Bronchiolitis in Young Infants N/A
Completed NCT01852929 - Sleep Apnea and Visual Perceptual Skill Learning N/A
Completed NCT00389909 - Dosing Chart for Calculating the First Dose of Doxapram in Premature Infants Phase 4
Completed NCT00188968 - Randomized Trial of Nasal Continuous Positive Airway Pressure or Synchronized Nasal Ventilation in Premature Infants. Phase 3
Not yet recruiting NCT05396274 - High Flow Nasal Oxygen Therapy Undergoing Colonoscopy N/A
Completed NCT02800213 - Ventilation Using a Bag Valve Mask With Supplemental External Handle N/A
Completed NCT02375230 - MRSOPA-Drills to Improve Mask Ventilation in the Delivery Room N/A