Accuracy of Surgical Guide in Computer Guided Implantology Clinical Trial
Official title:
Assessment of the Accuracy of Surgical Guide Designed From Dental Model Optical Scan Versus Impression Inversion With Markers Techniques in Computer Guided Implantology. Randomized Clinical Trial.
Verified date | December 2017 |
Source | Cairo University |
Contact | n/a |
Is FDA regulated | No |
Health authority | |
Study type | Interventional |
Dental model cast accuracy can be affected by many variables as tray material, impression
material and time elapsed before pouring the impression. All these factors would affect the
accuracy of the surgical guide
Impression inversion with markers technique avoids the dimension changes that may happen from
pouring of the dental model cast. Also it saves time as no need for optical scan of the model
cast and for scan appliance even in cases of multiple restoration. Adding markers to
impression tray ensures an accurate merge even if the patient has restored dentition that may
cause scatter during the CT/CBCT scan.
This study will is for Assessment of the Accuracy of Surgical Guide designed from Dental
Model Optical Scan versus Impression Inversion with Markers techniques in Computer Guided
Implantology.
Status | Recruiting |
Enrollment | 10 |
Est. completion date | April 1, 2018 |
Est. primary completion date | March 15, 2018 |
Accepts healthy volunteers | Accepts Healthy Volunteers |
Gender | All |
Age group | N/A and older |
Eligibility |
Inclusion Criteria: 1. Partially Edentulous patients seeking for dental implants 2. Patients with Bucco-lingual bone thickness more than 6 mm allowing flapless implant placement. 3. Medically free patients. Exclusion Criteria: 1- Patients with thin ridges. 2- Patients with systemic disease that may affect bone quality. 3- Patients with poor oral hygiene and active periodontal diseases. 4- Anatomical situations requiring regenerative procedure. 5- Completely edentulous patient 6-Patient with limited mouth opening |
Country | Name | City | State |
---|---|---|---|
Egypt | Faculty of Dentistry , Cairo university | Cairo |
Lead Sponsor | Collaborator |
---|---|
Cairo University |
Egypt,
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | Evaluation of angular deviation of virtual implants and actual implant position according to scanning protocol "optical scan of the model" Versus "impression inversion" using CBCT. | Immediate post operative | ||
Secondary | Evaluation of linear deviation of virtual implants and actual implant position according to scanning protocol " optical scan of the model" Versus " impression inversion " using CBCT | Immediate post operative |