Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT03116724
Other study ID # ideal depth of central line
Secondary ID
Status Completed
Phase N/A
First received
Last updated
Start date April 5, 2017
Est. completion date August 28, 2017

Study information

Verified date June 2020
Source Keimyung University Dongsan Medical Center
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

Total of 89 patients undergoing elective cardiac surgery will be enrolled.

Right CVC insertion begins at their intersection of the cricoid cartilage level and the triangular point where the sternal head of the SCM muscle meets the clavicular head. After insertion the central venous catheter through the right internal jugular vein and positioning it, the location of the tip of the central venous catheter will be confirmed by TEE.


Description:

Investigator confirms the location of the 2 cm from the junction between right atrium and superior vena cava to the end of the tip of the catheter using TEE, and measures the insertion depth of the catheter at insertion point. It is possible to find the ideal central venous catheter insertion depth in actual clinical practice in adult patient.

The ideal central venous catheter insertion depth can be measured accurately when the end of the central venous catheter is monitored with transesophageal ultrasonography, and it can be derived a meaningful formula for predicting the ideal central venous insertion depth from the patient's height .


Recruitment information / eligibility

Status Completed
Enrollment 89
Est. completion date August 28, 2017
Est. primary completion date August 25, 2017
Accepts healthy volunteers No
Gender All
Age group 18 Years and older
Eligibility Inclusion Criteria:

- adult patient over 18 years of age undergoing cardiac surgery under general anesthesia, requiring central venous catheter insertion through the right internal jugular vein and insertion of a TEE probe

Exclusion Criteria:

- Patients who disagree with the study.

- Patients who had difficulty in inserting the central line through the right internal jugular vein.

Study Design


Related Conditions & MeSH terms

  • Patient Safety During Central Venous Catheterization

Intervention

Procedure:
central venous catheterization through Rt. IJV
insertion at the intersection of the cricoid cartilage level and the triangular point where the sternal head of the SCM muscle meets the clavicular head placement of the tip of the catheter 2 cm away from the junction between right atrium and superior vena cava using TEE measurement of the depth of the catheter at insertion point

Locations

Country Name City State
Korea, Republic of Dongsan medical center Daegu

Sponsors (1)

Lead Sponsor Collaborator
Keimyung University Dongsan Medical Center

Country where clinical trial is conducted

Korea, Republic of, 

Outcome

Type Measure Description Time frame Safety issue
Primary depth of the central venous catheter in right internal jugular vein at time of insertion of the central venous catheter
See also
  Status Clinical Trial Phase
Completed NCT02711761 - Ideal Depth of Guide Wire for Central Catheterization N/A