Clinical Trial Details
— Status: Completed
Administrative data
| NCT number |
NCT03035318 |
| Other study ID # |
14-789 |
| Secondary ID |
|
| Status |
Completed |
| Phase |
N/A
|
| First received |
|
| Last updated |
|
| Start date |
September 2014 |
| Est. completion date |
December 2016 |
Study information
| Verified date |
April 2021 |
| Source |
The Cleveland Clinic |
| Contact |
n/a |
| Is FDA regulated |
No |
| Health authority |
|
| Study type |
Interventional
|
Clinical Trial Summary
The investigators propose a randomized clinical trial to evaluate the accuracy of glenoid
implant placement comparing four groups of patients. Group 1 consists of 3D imaging and
computer-generated surgical planning using standard DePuy instrumentation for placement of
the glenoid implant. This group is considered the standard of care. Group 2 consists of 3D
imaging and computer-generated surgical planning, with use of a SmartBone to trial the
standard DePuy instrumentation. (Group 2 is Group 1 with addition of the use of a SmartBone.)
Group 3 consists of 3D imaging and computer-generated surgical planning, with use of the IRI
technology including a SmartBone, but with metal legs instead of plastic legs in the
IRB#13-652 study. Group 4 consists of 3D imaging and computer-generated surgical planning,
with use of the RTI technology including a SmartBone.
We will measure implant placement based on 3D CT imaging. We will measure pre-operative bone
quality using quantitative CT scan to measure trabecular bone volume and correlate these
findings with bone samples removed from the humeral head and measured by microCT and
mechanical testing of the bone samples. These bone samples will be obtained as part of the
routine preparation of the humeral head for implant placement. This bone tissue is normally
removed and discarded as part of the standard of care for preparation of the bone for
placement of the humeral stem.
By comparing a computer generated pre-operative plan to the post-operative glenoid component
placement, we will be looking at three outcomes. First, we will determine the overall
difference in glenoid component placement between the four treatment groups. Second, we will
compare the placement between the technologies within and among surgeons. Third, we will
evaluate the difference in implant position between technologies based on severity of
pathology. The quality of the humeral head sample will be correlated to the possible
loosening of the implants.
Description:
The proposed clinical study will enroll patients indicated for standard of care anatomic
total shoulder arthroplasty. Participants will receive all pre-operative testing,
intra-operative care including all implants and post-operative care that is standard of care
and specific to the surgeon's and patient's decisions for care. The only change for Groups 2,
3 and 4 will be the type of surgical instruments used to place the glenoid guide pin,
retention of the humeral head to obtain bone tissue, placement of the beads and
post-operative CT scanning. In all cases the surgeon is able and allowed to use their own
surgical judgment to place the guide pin, prepare the bone and place the desired implant. In
all cases, the surgeon can use any and all of the standard instruments or guides provided by
the implant manufacturer as the surgeon would use if the patient was not enrolled in the
study. If the surgeon chooses not to use the IRI or RTI technology, then this would be noted
as a deviation in plan, the reasons recorded and the patient would be excluded from the study
without post-operative imaging and their pre-operative and intra-operative data would be
analyzed for the purpose of understanding the reasons for failure of the IRI or RTI
technology to provide assistance for refinement of the technology.
The participating surgeons will be Dr. Joseph Iannotti, Dr. Eric Ricchetti and Dr. Peter
Evans. Patients may have surgery at either Cleveland Clinic main campus or at Euclid
Hospital. If the procedure is performed at Euclid Hospital, post-operative CT scan and RSA
(if chosen), will be performed at main campus within 3 weeks after surgery. The patient will
be made aware of this at the time of enrollment and consent.
Using manufacturer (RSA biomedical, Umsa Sweden) provided beads and injector gun, four to
five 1 mm tantalum beads will be placed in the coracoid, acromion and glenoid. Exact
placement of these beads is at the discretion of the surgeon. Patient anatomy and operative
exposure will guide the surgeon to the best places to inject the beads; however the surgeon
will not be confined to a specific amount of beads in a specific location. The beads just
need to be spread out amongst the coracoid, acromion, and glenoid to establish reference
points for the RSA imaging. Prior studies looking at shoulder joint kinematics and implant
position have used this methodology of bead placement with successful study related outcomes.
Investigators have successfully placed bone beads in 22 patients currently treated in the
ongoing IRI clinical study without any difficulty or adverse events during or after surgery.
Postoperatively, all patients will receive a CT with Metal Artifact Reduction (MAR)and RSA
(if chosen) within 3 weeks of surgery. This will be a CT Scan performed with the patient's
arm by the side in a supine position using metal artifact reduction techniques. In addition
patients will receive a second CT scan and RSA imaging, provided they originally got RSA,
performed 1 year (± 1 month) from surgery. The second CT scan will be performed with MAR
techniques and with the patient in the lateral decubitus position with their arm in the
overhead position, again using metal artifact reduction techniques. The second set of images,
produced with a different body and arm position, also decreases metal artifact than those
obtained with the arm placed by the side. This position cannot be comfortably obtained until
3- 6 months after surgery and require healing of the tissues and rehabilitation of the
shoulder. Investigators have shown that in a small number of patients the glenoid component
can shift in position within the first 3-6 months after surgery making the first CT Scan more
accurate for implant position. The images obtained from the postoperative CT scans are placed
back into the surgical software and the 3D reconstruction of the postoperative scapula with
the implants is compared to the preoperative plan. Using measurement tools within the
software, developed at the Cleveland Clinic, investigators will compare the position of the
actual glenoid component placed in the patient with the desired position specified by the
plan. The use and validation of these imaging methods to precisely measure implant position
has been performed at the Cleveland Clinic in a prior IRB approved clinical trial (IRB
10-582).
Preoperatively, the high resolution quantitative CT will measure volumetric bone mineral
density and the trabecular network of the glenoid. When available, this will be applied to
the preoperative CT for those patients at Cleveland Clinic, Main Campus. Patients who have
their preoperative CT completed at non Main Campus facilities will have the standard of care
preoperative CT. This will be done at the same visit for the standard of care preoperative
CT. Micro CT imaging, which creates a 3D reconstruction of the fine bone structure, in
addition to microarchitecture analysis and mechanical testing, will allow assessment of the
bone tissue taken from the bone core sample. Between the preoperative imaging and the bone
tissue analysis, investigators will have data to properly determine the quality of the bone
stock surrounding the implant. Further correlating these data with RSA and 3D CT imaging of
implant movement, investigators can fully develop cause and effect of bone quality on glenoid
component loosening.
Study Statistics and Analysis:
Our goal is to have 20 subjects in each of the 4 treatment groups for a total of 80 subjects.
To control for subject withdrawal for various reasons after enrollment, we will enroll up to
120 subjects.
Statistical analysis plan:
Average deviations from plan for the 4 treatment groups will be compared using mixed-effects
ANOVA methods. Random effects will be included to account for correlation between
observations introduced as a consequence of multiple observations of deviation being taken on
a particular surgeon. If significant differences are found, multiple comparisons based on the
ANOVA model will be made to compare each pair of groups, and will use Holm's step-down
procedure to control the family-wise error rate of the tests.
All analyses will be done by Colin O'Rourke of Quantitative Health Sciences at Cleveland
Clinic using R software (version 3.0.0, Vienna, Austria). A significance level of 5% will be
used for all testing.