Clinical Trials Logo

Clinical Trial Summary

Vitamin E incorporated highly cross linked polyethylene (E-XLPE) was developed to increase oxidative resistance of highly cross-linked polyethylene (XLPE) without affecting mechanical properties. The investigators evaluated this type of polyethylene in a randomized clinical study, using Radiostereometric Analysis (RSA). The objective of this study was to compare the early-term wear of E-XLPE to a compression annealed polyethylene liner (C-XLPE, ArComXL®). The clinical outcome at two years was not expected to be affected by the choice of polyethylene.


Clinical Trial Description

First generation of modern highly cross-linked polyethylene (XLPE) was clinically introduced in 1998 and has in most countries become standard as bearing surface in total hip arthroplasty. Studies of these materials have shown significantly reduced femoral head penetration when compared to gamma sterilized conventional polyethylene.

Thermaly treating (melting or annealing) is often a part of the manufacturing process of highly cross-linked polyethylenes. The polyethylene is exposed to irradiation to achieve cross-linking and improve wear resistance. Cross-linking by irradiation increases the amount of free radicals in the material.These radicals must be eliminated or stabilized to avoid oxidative degradation over time.Thermal treatment improves oxidation resistance but potentially changes the mechanical properties of the polyethylene.

By annealing i.e. heat treatment under the melt temperature the material maintains better mechanical properties, but elimination of free radicals is suboptimal, which can lead to oxidation in vivo.Heat treatment of the polyethylene above the melt temperature will more effectively reduce or eliminate the amount of residual free radicals. This will increase oxidation resistance, but will negatively influence the mechanical properties of the material.

Due to these limitations new generations of cross-linked polyethylene materials have been developed. Introducing Vitamin E (α-tocopherol), a natural antioxidant into the material prevents oxidative degradation and stabilizes the free radicals found in irradiated polyethylene plastic. In laboratory tests, polyethylene liners with incorporated vitamin-E have demonstrated similar wear, greater strength and better resistance to oxidation compared with the first generation cross-linked polyethylene. Currently, there are only laboratory studies on vitamin E diffused polyethylene available.

The hypothesis in this study is that the early-term E-XLPE wear is low and comparable to a heat-treated XLPE. The investigators also hypothesize that implant fixation and clinical outcome at two years will be unaffected by the choice of polyethylene.

The investigators therefore evaluated the early bedding in and wear in an uncemented arthroplasty supplied with liners made of vitamin E diffusion doped XLPE (E1®, Biomet, Warsaw, IN, USA). In the control group the investigators used the same uncemented hip prosthesis with polyethylene liners manufactured to achieve high levels of crosslinking without sacrificing the mechanical strength and extinguish residual free radicals (ArComXL® , Biomet, Warzaw, IN, USA). ;


Study Design

Allocation: Randomized, Intervention Model: Parallel Assignment, Masking: Double Blind (Subject, Investigator), Primary Purpose: Supportive Care


Related Conditions & MeSH terms


NCT number NCT02801019
Study type Interventional
Source Sahlgrenska University Hospital, Sweden
Contact
Status Completed
Phase N/A
Start date June 2008
Completion date November 2011

See also
  Status Clinical Trial Phase
Completed NCT04657926 - A Trial of APPA in the Treatment of Knee Osteoarthritis Phase 2
Completed NCT02536833 - A Study Evaluating the Safety, Tolerability, and Efficacy of SM04690 Injected in the Target Knee Joint of Moderately to Severely Symptomatic Osteoarthritis Subjects Phase 2
Completed NCT03014037 - Comparing Mesenchymal Stem Cell Counts in Unilateral vs. Bilateral Posterior Superior Iliac Spine Bone Marrow Aspiration N/A
Recruiting NCT05937542 - A Qualitative Investigation of CLEAT Participants
Completed NCT03644615 - A Mindfulness Program (MBSR) in the Management of Symptomatic Hip and Knee Osteoarthritis N/A
Recruiting NCT06061367 - Muscles Strength and Gait Parameteres After TKA
Withdrawn NCT04976972 - A Comparison of Patients Receiving a Total Knee Replacement With Robotic Assistance or With Conventional Instrumentation N/A
Completed NCT05496205 - A SAD Study to Evaluate the Safety, Tolerability and PK/PD of iN1011-N17 in Healthy Volunteers Phase 1
Completed NCT03850665 - Comparison of Functional Outcome in Patients After Hip Arthroplasty Depending on Surgical Approach N/A
Completed NCT02826902 - Effect of Anesthesia on Quality of Recovery in Patients Undergoing Correctional Tibial Osteotomy - A Randomized Controlled Trial N/A
Completed NCT04402502 - Dynamic 4DCT to Examine Wrist Carpal Mechanics N/A
Completed NCT02923700 - Leukocyte-rich PRP vs Leukocyte-poor PRP for the Treatment of Knee Cartilage Degeneration: a Randomized Controlled Trial Phase 4
Completed NCT04564053 - Study of Safety, Tolerability and Pharmacokinetics of LNA043 in Japanese Osteoarthritis Participants Phase 1
Completed NCT05070871 - A Clinical Trial Investigating the Effect of Salmon Bone Meal on Osteoarthritis Among Men and Women N/A
Not yet recruiting NCT05036174 - Diphenhydramine Ointment for Knee Osteoarthritis N/A
Recruiting NCT02912429 - Onlay vs. Inlay Patellofemoral Arthroplasty N/A
Recruiting NCT02666443 - Low Dose Dexamethasone in Supraclavicular Blocks N/A
Active, not recruiting NCT02723929 - Effects of tDCS and tUS on Pain Perception in OA of the Knee
Withdrawn NCT02921594 - Kinematic Comparison of Vanguard XP and Vanguard CR Total Knee Arthroplasties N/A
Terminated NCT02820766 - Journey II BCS CMS Total Knee System Compared to Other PS Total Knee Systems in PT Setting N/A