Osteoarthritis Clinical Trial
Official title:
Comparison of Vanguard XP and Vanguard CR Total Knee Arthroplasties. A Randomized Controlled Trial Evaluating Early Component Migration by RSA and Patient Reported Outcome.
In the history of TKA several different types of prosthetic designs have been evolved in
order to optimize knee function after total knee replacement. The most common difference
between the prosthetic designs revolves around issues concerning the preservation of the
cruciate ligaments. The most popular prostheses have been the posterior stabilized
prosthesis (PS) in which both cruciate ligaments are resected and the posterior cruciate
retaining prosthesis (CR) in which only ACL is resected and PCL is preserved. Both these
prosthetic designs have shown excellent clinical results in the literature.
In the knee the role of the cruciate ligaments is to insure anterior/posterior stability,
but studies have also shown, that the cruciate ligaments contain proprioceptive mechanisms
which control joint kinematics essential for accurate knee function. One could therefore
imagine that a prosthetic design that preserves both cruciate ligaments would be superior to
prosthetic designs in which ACL or ACL/PCL is resected in achieving good clinical results
and patient satisfaction.
Only a few prosthetic designs, which preserve both cruciate ligaments, have been available
to the market. However studies based on fluoroscopic assays and gait analysis has shown that
this prosthetic design is superior to cruciate sacrificing designs in preserving normal knee
kinematics during activities of daily living after TKA. Studies, in which patients have
received two different types of prosthesis in each knee, have also shown that bi-cruciate
retaining TKA's is preferred, when compared to more constrained prosthetic designs.
The new Vanguard XP TKA system (Biomet®, Warsaw, Indiana, USA) is a further development of
the Vanguard TKA system, which has shown good clinical results in earlier studies. With the
new Vanguard XP system both cruciate ligaments are preserved. In theory this should result
in a more natural feeling of the knee because the stability and proprioceptive signals from
both cruciate ligaments are preserved. In order to investigate the potential benefits of
this new prosthetic design, the clinical and radiological results of knees receiving a
Vanguard XP and Vanguard CR prostheses are compared.
In this study we wish to investigate:
1. If the use of the Vanguard XP prosthesis will influence the migration of the femur- and
tibial components measured by Radiostereometric Analysis (RSA) when compared to the
Vanguard CR prosthesis.
2. If the use of the Vanguard XP prosthesis will result in increased participant knee
function, satisfaction and quality of life when compared to the Vanguard CR prosthesis.
3. If the use of the Vanguard XP prosthesis will influence radiologic signs of osteolysis,
complication rates and revision rates when compared to the Vanguard CR prosthesis.
This project is carried out as a randomized controlled double-blinded trial, in which the
clinical and radiological outcomes after treatment of knee osteoarthritis with insertion of
either a Vanguard XP or Vanguard CR prosthesis is compared.
1. Objectives Primary objective The primary objective of this study is to compare
stability and fixation by RSA of Vanguard XP to that of Vanguard CR.
Secondary objective Secondary objective of this study is to assess the patient reported
outcomes of Vanguard XP in comparison to Vanguard CR.
2. Background The primary goal of Total Knee Replacement surgery in the treatment of knee
osteoarthritis is to reduce pain and restore knee function (stability and range of motion)
in order to increase patient mobility and quality of life.
At Copenhagen University Hospital of Hvidovre, patients with severe osteoarthritis of the
knee are treated with insertion of a cemented total knee prosthesis in which the anterior
cruciate ligament is resected and the posterior cruciate ligament is retained (CR).
In the history of TKA several different types of prosthetic designs have been evolved in
order to optimize knee function after total knee replacement. Most differences between the
prosthetic designs revolve around issues concerning the preservation of the cruciate
ligaments. The most popular prostheses used have been the posterior stabilized prosthesis
(PS) in which both cruciate ligaments are resected and the posterior cruciate retaining
prosthesis (CR) in which only ACL is resected and PCL is preserved. Both these prosthetic
designs have shown excellent clinical results in the literature.
In the knee the role of the cruciate ligaments is to insure anterior/posterior stability,
but studies have also shown, that the cruciate ligaments contain proprioceptive mechanisms
which control joint kinematics essential for accurate knee function. One could therefore
imagine that a prosthetic design that preserves both cruciate ligaments would be superior to
prosthetic designs in which ACL or ACL/PCL is resected in achieving good clinical results
and patient satisfaction.
Only a few prosthetic designs, which preserve both cruciate ligaments, have been available
to the market. However studies based on fluoroscopic assays and gait analysis has shown that
this prosthetic design is superior to cruciate sacrificing designs in preserving normal knee
kinematics during activities of daily living after TKA13-16. Studies, in which patients have
received two different types of prosthesis in each knee, have also shown that bi-cruciate
retaining TKA's is preferred, when compared to more constrained prosthetic designs17-19.
The new Vanguard XP TKA system (Biomet®, Warsaw, Indiana, USA) is a further development of
the Vanguard TKA system, which has shown good clinical results in earlier studies11-12. With
the new Vanguard XP system both cruciate ligaments are preserved. In theory this should
result in a more natural feeling of the knee because the stability and proprioceptive
signals from both cruciate ligaments are preserved. In order to investigate the potential
benefits of this new prosthetic design, the clinical and radiological results of knees
receiving a Vanguard XP and Vanguard CR prostheses are compared.
In this study we wish to investigate:
1) If the use of the Vanguard XP prosthesis will influence the migration of the femur- and
tibial components measured by Radiostereometric Analysis (RSA) when compared to the Vanguard
CR prosthesis.
2) If the use of the Vanguard XP prosthesis will result in increased participant knee
function, satisfaction and quality of life when compared to the Vanguard CR prosthesis.
3) If the use of the Vanguard XP prosthesis will influence radiologic signs of osteolysis,
complication rates and revision rates when compared to the Vanguard CR prosthesis.
3. Device description Please see separate application for premarket testing. The Vanguard XP
(with the XP tibial tray and XP tibial bearing to be used in this study) is not yet
CE-marked.
4. Project design Project type This project is carried out as a randomized controlled
double-blinded trial, in which the clinical and radiological outcomes after treatment of
knee osteoarthritis with insertion of either a Vanguard XP or Vanguard CR prosthesis are
compared.
After informed consent is obtained, participants are randomized to receive either a Vanguard
XP or Vanguard CR prosthesis. Allocation of the patient to one of the two treatment groups
is done in the operating room after surgical verification of both cruciate ligaments being
intact. Non-transparent envelopes are used for the randomization process. Participants are
unaware of which prosthesis they receive and the research coordinator handling the collected
questionnaires postoperatively is also unaware of which prosthesis the patient has received.
Time schedule Recruitment of participants to this project is expected to begin in October
2013 or as soon as permission from the local Ethics Committee and the National Board of
Health is obtained. 50 participants are to be randomized (25 participants in each study
group). Recruitment is expected completed after a period of 1 year. Inclusion and
randomization of approximately 5 participants per month is considered realistic regarding
the logistical capacity for the additional necessary studies in this study. The project is
expected to be completed 10 years after recruitment of the last participant (fall of 2024).
Participant termination At their own will participants can choose to leave the project at
any time. Participants can also be withdrawn from the project at any time, if this is
considered necessary by the investigators, e.g. in the event of deep infection leading to
replacement of the prosthesis or long-term immobilisation because of comorbidity. If a
participant is withdrawn or rescinds their consent, a "Lost to Follow-up" case report form
will be completed detailing the reason for the participant's withdrawal.
Data recording Data relevant for this project will be registered in a data sheet. An
individual data sheet will be kept for each recruited participant. Data will also be
aggregated and stored electronically. The storage of data will be done according to the
rules posted by the Danish Data Protection Agency. This project will be notified to and
approved by the Danish Data Protection Agency before recruitment of partisipants is
initiated.
5. Participant population 50 participants with knee osteoarthritis set to receive primary
cemented total knee prosthesis at Copenhagen University Hospital Hvidovre.
Number of participants 50 recruited patients (25 in each group) are randomized to receive
either Vanguard XP or Vanguard CR prosthesis.
Patients may be excluded intraoperatively, before randomization, if one or both of the
cruciate ligaments are found to be missing or totally ruptured. We estimate that 20 % of
enrolled patients will be excluded due to this, and therefore recruitement of 60 patients is
needed.
Prior to recruitement of patients for the randomized study we will conduct a pilot study
which will include 5 patients who will all receive the Vanguard XP.
The study's primary outcome measure is implant migration measured by RSA. If the minimally
relevant total migration of the prosthesis measured by RSA is set to 0.2 mm1 then a total of
18 participants must be enrolled in each study group to show a statistically significant
difference (95 % confidence, 80 % power).
In this study 2 x 25 participants are included. This will insure sufficient statistical
power despite a dropout of 20%.
The power calculation is based on reaching sufficient power when a comparison of the two
study groups is carried out.
Inclusion criteria • Patients with primary knee osteoarthritis set to receive a primary
unilateral cemented total knee arthroplasty at Copenhagen University Hospital Hvidovre.
- Participants must be >18 years of age.
- Participants must be able to speak and understand Danish.
- Participants must be able to give informed consent and be cognitively intact.
- Participants must be expected to be able to complete all postoperative controls.
- Participants must not have severe comorbidities, ASA-score ≤ 3. Exclusion criteria
- Terminal illness.
- Rheumatoid arthritis.
- Prior open surgery on the affected knee.
- Prior arthroscopic surgery with surgery on anterior and/or posterior cruciate ligament
(meniscal surgery only does not lead to exclusion).
- Prior high-energy trauma to the affected knee.
- Prior history of anterior and/or posterior cruciate ligament rupture.
- Suspicion of anterior and/or posterior cruciate ligament rupture at clinical
examination.
- Documented osteoporosis with patient in active medical treatment.
- Comorbidity with altered pain perception (e.g. DM with neuropathy).
- Participants that develop deep infection in the follow-up period are excluded from the
study.
Regarding RSA assays
• Participants with less than 3 Tantalum beads visible around the Femur- or Tibia component
on RSA assays are excluded from the migration measurements. Data regarding secondary
objectives from these subjects will be included.
Regarding intraoperative exclusion • If the anterior and/or posterior cruciate ligaments are
found missing or totally ruptured at direct intraoperative visualization, patients excluded
at this point and will receive the department's standard prosthesis (Vanguard CR if
posterior cruciate ligament is intact).
Regarding contraception
• Patients who receive knee prosthesis have most often reached the non-fertile age (50+). In
the case that a fertile woman participates in the study it will be ensured that she is not
pregnant.
Intervention group After being allocated to either of the two groups, participants will
receive either Vanguard XP or Vanguard CR prosthesis. After discharge outpatient controls
are carried out after 3 months, 1, 2, 5, and 10 years postoperatively. RSA assays are
performed postoperatively and after 3 months, 1, 2, 5, and 10 years. Patients who meet the
inclusion criteria but do not wish to participate in the study will receive the standard
treatment for knee osteoarthritis at our institution, which is a cemented TKA and outpatient
follow-up 3 months postoperatively.
6. Methods The study is conducted in accordance with the CONSORT statement. The project in 5
steps
1. Project information and signed consent before surgery.
2. Intraoperative assessment of the cruciate ligaments with exclusion of the patient if
the anterior and/or posterior cruciate ligaments are found missing or totally ruptured.
3. Surgery with insertion of either Vanguard XP or Vanguard CR prosthesis. Tantalum beads
are placed in the bone around the femur- and tibial components. Surgery is performed at
Copenhagen University Hospital Hvidovre.
4. Postoperatively, participants are admitted to a dedicated fast track arthroplasty unit
and will receive standard treatment after TKA until discharge. Discharge criteria are
ability to walk >70 m with crutches or better, ability to get in and out of bed as well
as up from a chair, and sufficient oral pain treatment. Before discharge RSA is
performed.
5. 3 months and 1, 2, 5. and 10 years postoperatively participants are seen on an
outpatient basis.
Demographic data, surgery time and length of hospital stay are also registered.
Surgery procedure Surgery is performed as described in the manufacturer's technical guide.
After randomization participants will receive either a cemented Vanguard XP or Vanguard CR
prosthesis.
One of three senior surgeons (Henrik Husted, Kristian Otte, Anders Troelsen) dedicated to
knee arthroplasty surgery will perform all operations with an assistant.
Technique: A standard medial Para patellar incision is used. Femur and tibial surfaces are
prepared using standard cutting guides. When the CR prosthesis is used ACL is resected and
PCL is spared. When the XP prosthesis is used both ACL and PCL are spared. The XP prosthesis
is used with a tibail tray and a bearing surface for this purpose. A minimum of six 1 mm
Tantalum beads are placed in the distal femur and proximal tibia. A sawbones phantom study
to detect optimal placement of beads will be performed prior to operation of the first
patient. Femur- and tibial components are cemented to the bone. Soft tissue balancing is
performed to ensure optimal stability and ROM. An E1-vitamin enriched polyethylene tibial
liner is used. Resurfacing of patella is performed in all cases. Joint capsule and subcutis
are closed using tied nuts. Skin is closed with staples. No drains are used.
Postoperatively, participants will receive standard pain treatment and rehabilitation until
discharge2.
Measurements with RSA Since the 1970ies, RSA has been used to measure the migration of
implants in relation to the surrounding bone. Peroperatively, 1 mm Tantalum beads are placed
in the bone surrounding the prosthesis using a specialized instrument. Postoperatively,
simultaneous radiographs from two different angles are used to visualize distances between
the prosthesis and the Tantalum beads three-dimensionally using a special computer software
programme (Model Based RSA)3. Then the migration of the prosthesis over time can be
calculated. Migration of both the femur- and tibia components can then be calculated.
Radiographs are performed at the Radiological Department, Copenhagen University Hospital
Hvidovre. Participants are placed in the supine position and the lower leg is placed on a
premade cushion. The x-ray tubes are placed 145 cm above the floor in a mutual angle of 44
degrees (+/-22 degrees relative to the sagittal axis of the participant) so that the path of
the beam from each x-ray tube passes through the knee of the participant. Standard x-ray
films are placed in a calibration box designed to Model Based RSA. Using Model Based RSA
software and pre-scanned models of the prosthesis, the radiographs are used to establish a
three-dimensional coordinate presenting the relations between the prosthesis and the
Tantalum beads. Distances between the Tantalum beads and the prosthesis can be calculated
and subsequently used to calculate migration of the prosthesis over time.
In order to be able to calculate migration of the prosthesis, at least three Tantalum beads
around the femur- and tibial components should be visual on the RSA radiographs. If this is
not achieved, the participant is excluded from the migration measurements. In order to
address this issue at least 6 Tantalum beads are placed in the distal femur and proximal
tibia preoperatively.
7. Registrations All registrations are done prospectively. Primary objectives
Migration/rotation: Migration of the prosthesis measured by RSA3. Implant-migration/rotation
is defined as changes in distances between the prosthesis and the Tantalum beads over time.
Participant perceived knee function: Participant perceived knee function is evaluated
preoperatively and at 3 months, 1, 2, 5, and 10 years follow-up using the validated
Forgotten Joint Score (FJS)4 and Oxford Knee Score (OKS)5.
Secondary objectives Health related quality of life (HRQoL): Participant perceived HRQoL is
evaluated preoperatively and at 3 months, 1, 2, 5, and 10 years follow-up using the
validated EQ-5D Range of motion (ROM): Active and passive knee ROM is measured
preoperatively and at 3 months, 1, 2, 5, and 10 years follow-up using a goniometer6.
Periprosthetic osteolysis: Radiological signs of periprosthetic osteolysis are evaluated on
plain radiographs at 1, 2, 5, and 10 years follow-up.
Knee pain: Knee pain is evaluated at 3 months, 1, 2, 5, and 10 years follow-up using the
Visual Analogue Scale (VAS)7 in which 0 represents no pain at all and 10 represents worst
pain imaginable.
Satisfaction with the knee: At 3 months, 1, 2, 5, and 10 years participants are asked to
describe their satisfaction with the knee using the VAS-scale. 0 is used when the
participant is maximally dissatisfied with the knee.
Expectations/fulfilment of expectations: Preoperatively participants are asked about their
expectations to the forthcoming knee replacement. At 1, 2, 5, and 10 years follow-up,
participants are asked to evaluate how well the knee replacement met their expectations
using the VAS-scale. 0 is used when expectations were not fulfilled at all and 10 is used
when expectations were fully fulfilled.
Surgery time: Duration from the start of the incision until staples are placed is
documented.
Length of hospital stay: Length of hospital stay defined as from the day of surgery until
discharge is documented.
Complications: Thrombo-embolic complications, wound healing complications, infections, nerve
palsies and revisions are documented.
Peroperative release: If peropertive release (medial, lateral, posterior) is performed in
order to obtain stability, this is documented.
8. Risks and adverse effects The risks in this study are related to: 1) Insertion of
Tantalum beads in the bone, 2) Additional radiation in relation to the RSA-assays, and 3)
The use of a new prosthetic design.
1. Insertion of Tantalum beads in the bone in order to carry out RSA-assays has been done
increasingly over the last 25 years. In the literature, no side effects have been
reported regarding insertion of Tantalum beads when these have been used for
RSA-assays. Tantalum is also used in sutures and staples and has proven bio-convertible
and without tendency to corrode bone8-9.
2. In this study RSA-assays are carried out postoperatively and at 3 months, 1, 2, 5, and
10 years follow-up. At 3 months follow-up an additional RSA-assay is performed to
ensure the precision of the setup. This means that each participant is exposed to 5
additional RSA-assays. The radiation dose used at each RSA-assay is equivalent to that
of conventional radiographs, 0.2 mSV. Each participant is therefore exposed to an
additional radiation dose of 1.4 mSV. The background radiation in Denmark is ≈ 2-3
mSV/year. The additional radiation that each participant is exposed to in this study is
equivalent to 6-8 months of background radiation. Therefore we believe that the
RSA-assays will not cause additional risks for the participants in this study10.
3. In this study a new prosthetic design, the Vanguard XP TKA system (Biomet®, Warsaw,
Indiana, USA), is tested. The Vanguard XP system has obtained FDA-approval in the USA
and is the further development of the Vanguard system, which has shown good clinical
results in earlier studies11-12. We therefore find it highly relevant to investigate
the results of primary total knee replacement with the Vanguard XP TKA system. We do
not believe that the use of this new prosthetic design will cause additional risks for
the participants in this study.
Investigators Surgery procedures, investigations and radiological assays are carried
out by trained medical doctors, nurses, physiotherapists and radiologists associated to
the Orthopaedic and Radiology departments at Copenhagen University Hospital Hvidovre.
Unintended events Unintended events are defined as any unintended and unfavourable
occurrences, symptoms or illnesses experienced by the participants in this study,
regardless of its coherence with the study.
Unintended events are documented continuously. Data regarding unintended events will be
retrieved from the participant's medical records by the primary investigator. Data from
participant medical records will not be disclosed to a third Party.
Severe unintended events
Severe unintended events are defined as serious unintended occurrences or side effects
that cause:
• Death.
• Life threatening situations.
• Admittance to an intensive care unit.
• Permanent severe disabilities.
In the case of a severe unintended event, the investigators of this study are obligated
to assess if the event is caused by the interventions introduced in this study, e.g.
the insertion of Tantalum beads in the bone. In this assessment, the following factors
should be included:
- Coherence in time.
- Accordance with known consequences of the treatment or investigations.
- Alternative reasons for the unintended event. If the severe unintended event is
considered caused by the interventions introduced in this study, the project will
be terminated ahead of time.
9. Ethics At Copenhagen University Hospital Hvidovre, treatment of osteoarthritis with TKA
is mastered on a super-specialist level. We find this study to be highly relevant regarding
the potential beneficial effects of the new prosthetic design (Vanguard XP) on postoperative
knee function and patient perceived outcome.
The study is conducted in accordance with principals described in the Helsinki declaration.
Participants in the study are covered by the patient insurance of Copenhagen University
Hospital Hvidovre.
This protocol, along with written participant information and consent declaration, is to be
approved by the local Ethics Committee before enrolments of participants are commenced.
The project will be registered at clinicaltrials.gov. The project will be approved by the
Danish Data Protection Agency. It is the responsibility of the primary investigator to
inform the local Ethics Committee if any changes are made to the protocol or if any severe
adverse effects occur. The primary investigator stores all correspondence regarding the
study.
All participants will receive oral and written information about the study before consent.
It is the responsibility of the primary investigator that the information to the participant
is adequate. Participants are included when signed consent from the participant is obtained.
Project information is then given in an undisturbed environment (in a closed examination
room) by an authorized investigator of this study. Project information is given at the first
outpatient consultation, when treatment with insertion of a TKA is decided. A nurse is
present when the information is given. Participants are informed about the right to having a
dependent present when project information is given. Participants are informed that a period
of consideration of at least 2 weeks is an opportunity along with the right to a second
consultation. Signed consent, however, is to be given latest at admittance before surgery.
The oral information is in accordance with the written information and is adjusted to the
age, educational level and social conditions of the participant. It is ensured that the
participant has understood the content of both the oral and written information before
signed consent is given.
It is the responsibility of the primary investigator that the authorized investigator is
adequetly informed about the study and academically qualified to giving the oral
information.
10. Data recordings Participants in this study are identified with an assigned allocation
number. At the end of the study all patient related data are destroyed.
All sensitive personal data regarding participants will be stored in accordance with
guidelines presented by the Personal Data Act. Personal data regarding participants will be
treated anonymously. The study will be reported to the Danish Data Protection Agency. The
primary investigator will process all data. Participants will receive oral and written
information concerning the handling of sensitive personal data.
11. Statistics The STATA statistical software will be used when processing data in this
study. Comparative statistics will be used based on the distribution of data.
12. Financial conditions This project is financed by Dept. of Orthopaedic Surgery,
Copenhagen University Hospital Hvidovre with finantial support from Biomet®, Warsaw,
Indiana, USA.
The investigators of this study have independently initiated the project. Besides this
study, the primary investigator has no affiliation to Biomet®. 13. Publications The results
of this project are expected to be published in an international medical journal. The
primary investigator prepares the manuscript, which is approved by the remaining
investigators of the project. The results of this study are also expected to be presented at
national and international orthopaedic conventions. If publication is not achieved, the
results of this study (positive, negative or inconclusive) will be presented on the homepage
of our institution.
Co-authorship is awarded according to the Vancouver rules. The investigators will be the
authors in the following order:
Morten G. Thomsen, Henrik Husted, Kristian S. Otte, Kasper Gosvig, Anders Troelsen
Biomet will not be able to prevent publication of the results of this study.
;
Allocation: Randomized, Endpoint Classification: Efficacy Study, Intervention Model: Parallel Assignment, Masking: Double Blind (Subject, Caregiver, Investigator, Outcomes Assessor), Primary Purpose: Treatment
| Status | Clinical Trial | Phase | |
|---|---|---|---|
| Completed |
NCT04657926 -
A Trial of APPA in the Treatment of Knee Osteoarthritis
|
Phase 2 | |
| Completed |
NCT02536833 -
A Study Evaluating the Safety, Tolerability, and Efficacy of SM04690 Injected in the Target Knee Joint of Moderately to Severely Symptomatic Osteoarthritis Subjects
|
Phase 2 | |
| Completed |
NCT03014037 -
Comparing Mesenchymal Stem Cell Counts in Unilateral vs. Bilateral Posterior Superior Iliac Spine Bone Marrow Aspiration
|
N/A | |
| Recruiting |
NCT05937542 -
A Qualitative Investigation of CLEAT Participants
|
||
| Completed |
NCT03644615 -
A Mindfulness Program (MBSR) in the Management of Symptomatic Hip and Knee Osteoarthritis
|
N/A | |
| Recruiting |
NCT06061367 -
Muscles Strength and Gait Parameteres After TKA
|
||
| Withdrawn |
NCT04976972 -
A Comparison of Patients Receiving a Total Knee Replacement With Robotic Assistance or With Conventional Instrumentation
|
N/A | |
| Completed |
NCT05496205 -
A SAD Study to Evaluate the Safety, Tolerability and PK/PD of iN1011-N17 in Healthy Volunteers
|
Phase 1 | |
| Completed |
NCT03850665 -
Comparison of Functional Outcome in Patients After Hip Arthroplasty Depending on Surgical Approach
|
N/A | |
| Completed |
NCT02826902 -
Effect of Anesthesia on Quality of Recovery in Patients Undergoing Correctional Tibial Osteotomy - A Randomized Controlled Trial
|
N/A | |
| Completed |
NCT04402502 -
Dynamic 4DCT to Examine Wrist Carpal Mechanics
|
N/A | |
| Completed |
NCT02923700 -
Leukocyte-rich PRP vs Leukocyte-poor PRP for the Treatment of Knee Cartilage Degeneration: a Randomized Controlled Trial
|
Phase 4 | |
| Completed |
NCT04564053 -
Study of Safety, Tolerability and Pharmacokinetics of LNA043 in Japanese Osteoarthritis Participants
|
Phase 1 | |
| Completed |
NCT05070871 -
A Clinical Trial Investigating the Effect of Salmon Bone Meal on Osteoarthritis Among Men and Women
|
N/A | |
| Not yet recruiting |
NCT05036174 -
Diphenhydramine Ointment for Knee Osteoarthritis
|
N/A | |
| Recruiting |
NCT02666443 -
Low Dose Dexamethasone in Supraclavicular Blocks
|
N/A | |
| Recruiting |
NCT02912429 -
Onlay vs. Inlay Patellofemoral Arthroplasty
|
N/A | |
| Active, not recruiting |
NCT02723929 -
Effects of tDCS and tUS on Pain Perception in OA of the Knee
|
||
| Terminated |
NCT02820766 -
Journey II BCS CMS Total Knee System Compared to Other PS Total Knee Systems in PT Setting
|
N/A | |
| Withdrawn |
NCT02921594 -
Kinematic Comparison of Vanguard XP and Vanguard CR Total Knee Arthroplasties
|
N/A |