Clinical Trials Logo

Clinical Trial Details — Status: Withdrawn

Administrative data

NCT number NCT00175162
Other study ID # 20030249
Secondary ID
Status Withdrawn
Phase N/A
First received
Last updated
Est. completion date December 2010

Study information

Verified date October 2010
Source University of Aarhus
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

The purpose of this study is to compare the early migration and periprosthetic bone changes of two total knee arthroplasties fixated with two different type bone cement.


Description:

Around 4% of total knee arthroplasties (TKA) are revised 15 years after the primary operation, most due to loosening of the implant. About 70 % TKA are fixed with bone cement and in general the results after total knee arthroplasty are excellent and with the existing technique about 95% well functioning prostheses can be expected 10 years post surgery. The most serious late complication to surgery is aseptic loosening of the implants; and this remains one of the main courses of failure of both uncemented and cemented total knee implants. Implant design, method of fixation, the quality of bone cement, surgerytechnique and the bone mass density are some of the factors that have a large influence on implant stability. Fixation of the tibia baseplates in total knee arthroplasty can be obtained by different type bone cement. In this project we are using a modular tibia component with a central wedge-shaped stem. Upon randomization at surgery the implant is consolidated in the bone with either low-viscosity or high-viscosity bone cement. The purpose of this study is to compare the early migration of a total knee implant fixated with two different bone cements using RSA (radio stereophotogrammetric analysis) for evaluation. Furthermore, we will make research into the periprosthetic bone and its changes post surgery using DEXA. Finally, the extend of the expected micromovements between the polyethylen liner and the metal backing of the titanium plateau will be compared and taken into account with the results. Several factors can influence the long-term survival of cemented TKA. Bone-sclerosing at the tibia condyles may induce a problem with cement penetration into the cancellous bone. Furthermore, blood-contamination in the cancellous bone may reduce the shear-strength at the bone-cement site by 50%. A solid cement-implant interface limits the amount of debris in the interface bringing down the risk of radiolucent lines and osteolysis. The tibial implant used in this study is designed with a rim under the plateau to support the cement layer on the tibial condyles at the time of fixation. The implant has a stem making it more resistant to shearing forces. In this study we primarily consider the bone cement viscosity on the outcome. Both types are used in hip-arthroplasties with good results. To evaluate both the implant-bone micromotions and the polyethylen-implant micromovements metal markers have been placed on the tibial implants pre-operatively. They will also be inserted into the tibial bone and into the tibial polyethylen intra-operatively allowing us to evaluate stereo x-rays by a photogrammetric computer analyses called RSA at the Orthopaedic Center, Aarhus University Hospital. Follow-up stereo x-rays will be scheduled for 1 week, 3 months, 6 month, 1 years and 2 years post-surgery. Periprostetic bone density will be evaluated at 1 week, 1 year and 2 years upon inclusion at the Orthopaedic Center, Aarhus University Hospital.


Recruitment information / eligibility

Status Withdrawn
Enrollment 0
Est. completion date December 2010
Est. primary completion date
Accepts healthy volunteers No
Gender All
Age group 70 Years and older
Eligibility Inclusion Criteria: - Patients with one- or double-sided primary knee arthrosis. - Patients with a sufficient bone quality for implantation of knee prosthesis. - Informed and written patient consent. Exclusion Criteria: - Patients with neuromuscular or vascular diseases in the affected leg. - Patients who peroperatively are estimated unsuitable for knee arthroplasty e.g. due to bone cysts or dilution of the bone mass. - Patients who use non-steroid anti-inflammatory drugs (NSAID) and cannot refrain from taking them postoperatively (this includes COX-2-inhibitors). - Patients with osteoporosis estimated from the preoperative x-ray or former diagnosis of osteoporo-sis. - Patients with knee arthrosis following fracture sequelae. - Women, who are pregnant or are at risk of getting pregnant throughout the 2 year follow-up.

Study Design


Related Conditions & MeSH terms


Intervention

Device:
Osteopal G vs. Refobacin-Palacos R bone cement
Bone cement

Locations

Country Name City State
Denmark Orthopaedic Center, Aarhus University Hospital Aarhus

Sponsors (3)

Lead Sponsor Collaborator
University of Aarhus Aarhus University Hospital, Zimmer Biomet

Country where clinical trial is conducted

Denmark, 

Outcome

Type Measure Description Time frame Safety issue
Primary Tibial prosthesis part migration evaluated by RSA. 2011
Secondary Micromotion of the modular polyethylen liner in both type prostheses evaluated by RSA estimating the role of wear. 2011
See also
  Status Clinical Trial Phase
Completed NCT04657926 - A Trial of APPA in the Treatment of Knee Osteoarthritis Phase 2
Completed NCT02536833 - A Study Evaluating the Safety, Tolerability, and Efficacy of SM04690 Injected in the Target Knee Joint of Moderately to Severely Symptomatic Osteoarthritis Subjects Phase 2
Completed NCT03014037 - Comparing Mesenchymal Stem Cell Counts in Unilateral vs. Bilateral Posterior Superior Iliac Spine Bone Marrow Aspiration N/A
Recruiting NCT05937542 - A Qualitative Investigation of CLEAT Participants
Completed NCT03644615 - A Mindfulness Program (MBSR) in the Management of Symptomatic Hip and Knee Osteoarthritis N/A
Recruiting NCT06061367 - Muscles Strength and Gait Parameteres After TKA
Withdrawn NCT04976972 - A Comparison of Patients Receiving a Total Knee Replacement With Robotic Assistance or With Conventional Instrumentation N/A
Completed NCT05496205 - A SAD Study to Evaluate the Safety, Tolerability and PK/PD of iN1011-N17 in Healthy Volunteers Phase 1
Completed NCT03850665 - Comparison of Functional Outcome in Patients After Hip Arthroplasty Depending on Surgical Approach N/A
Completed NCT02826902 - Effect of Anesthesia on Quality of Recovery in Patients Undergoing Correctional Tibial Osteotomy - A Randomized Controlled Trial N/A
Completed NCT04402502 - Dynamic 4DCT to Examine Wrist Carpal Mechanics N/A
Completed NCT02923700 - Leukocyte-rich PRP vs Leukocyte-poor PRP for the Treatment of Knee Cartilage Degeneration: a Randomized Controlled Trial Phase 4
Completed NCT04564053 - Study of Safety, Tolerability and Pharmacokinetics of LNA043 in Japanese Osteoarthritis Participants Phase 1
Completed NCT05070871 - A Clinical Trial Investigating the Effect of Salmon Bone Meal on Osteoarthritis Among Men and Women N/A
Not yet recruiting NCT05036174 - Diphenhydramine Ointment for Knee Osteoarthritis N/A
Recruiting NCT02912429 - Onlay vs. Inlay Patellofemoral Arthroplasty N/A
Recruiting NCT02666443 - Low Dose Dexamethasone in Supraclavicular Blocks N/A
Active, not recruiting NCT02723929 - Effects of tDCS and tUS on Pain Perception in OA of the Knee
Withdrawn NCT02921594 - Kinematic Comparison of Vanguard XP and Vanguard CR Total Knee Arthroplasties N/A
Terminated NCT02820766 - Journey II BCS CMS Total Knee System Compared to Other PS Total Knee Systems in PT Setting N/A