Clinical Trials Logo

Clinical Trial Summary

The choice between ultra-congruent (UC) insert or posterior cruciate ligament-stabilized (PS) insert in posterior cruciate ligament (PCL) sacrificing total knee arthroplasty (TKA) remains debatable. Despite the potential advantages of the UC insert over PS insert with its different design, there are concerns about inferior clinical outcome related to its use. Therefore, isokinetic performance was used in this study to objectively evaluate knee function after TKA and the clinical scores of the patients were also evaluated. To the best of our knowledge, no prospective randomized study has compared the isokinetic performance of the knee following the use of UC and PS inserts in TKA. The hypothesis of the present study was that compared with the PS insert, the UC insert would be associated with a lower clinical outcome and isokinetic performance following TKA. A total of 65 patients scheduled to undergo TKA on for primary knee osteoarthritis were randomly assigned to either the UC (32 patients) or the PS group (33 patients). The Knee Society Score (KSS) and isokinetic performance results of each patient were recorded preoperatively and at postoperative 3, 6 and 12 months. The physiatrist performing isokinetic tests and patients were blinded to the study.


Clinical Trial Description

Eligibility of all patients between 55 and 80 years, scheduled to undergo unilateral TKA on for primary knee osteoarthritis will be evaluated. The exclusion criteria are rheumatological joint diseases, previous knee surgery, neuromuscular diseases, bilateral TKA, or insufficiency of collateral ligaments. Patients will be randomized in a 1:1 ratio via computer-generated randomization using Microsoft Excel 2016 (Microsoft Corporation, Seattle, WA, USA) to be allocated in the UC insert or PS insert group before the operation. Unblinded senior resident will implement the randomization. Patients and physiatrists performing isokinetic measurements will be blinded to group allocation. During the UC and PS operations, Vanguard® Complete Knee System prosthesis (Zimmer Biomet Inc., Warsaw, IN, USA) will be implanted using the same surgical technique in all patients. The Vanguard anterior-stabilized (AS) insert is a UC deep-dish design with a 10 mm prominent anterior lip and 5mm posterior lip. This bone-conserving design prevents anterior femoral subluxation because of the prominent anterior lip. The insert design allows it to be used with the Vanguard cruciate-retaining femoral component and the highly congruent articulating surface increases rotational stability. There is more contact area between the femoral component and the weight-bearing surface to decrease the shear stress between the femur and polyethylene insert. A tourniquet will be inflated to pressure of 300 mmHg after spinal anesthesia. All operations will be performed with the same surgical technique by a single senior surgeon. Patellar surface arthroplasty will be performed in all the cases. Both femoral and tibial prostheses will be implanted with pressured bone cement. A suction drain will be placed inside the knee capsule. On the morning of the first day after surgery patients will be mobilized under the supervision of the physical therapist. All patients will undergo the same rehabilitation procedure during the outpatient period and will be examined by the same physiatrist at the regular 3, 6, and 12-month follow-up visits. The primary outcome is isokinetic performance, measured as peak knee extensor and flexor torque values in Newton-meters, on the operated knee. Measurements wilil be done preoperatively and at 3, 6, and 12-month follow-up examinations under the supervision of the same physiatrist. At same time points, the Knee Society Score (KSS) will be evaluated as well. Isokinetic measurements will be performed using a Biodex System III Isokinetic Dynamometer, version 3.03 (Biodex Medical Inc., Shirley, NY, USA) by the same senior physiatrist. Patients will be positioned on the dynamometer with the hip in 90° in a sitting position for the knee flexion and extension measurements. Lateral movement of the knee will be prevented during full extension and flexion of the knee by a thigh strap on the operated leg. The physical therapist will help the patients to achieve proper positioning before each test. Concentric isokinetic knee flexion-extensions will be assessed at a preset velocity of 60º/sec, over a range of motion of 0º to 110º for both parameters. A fixed number of 10 flexion-extension repetitions will be completed by each patient. Instructions will be provided, and one trial repetition will then performed by all patients before the measurements were taken. Sample size estimation will be performed using the extension peak torque as a primary effect variable. As there is no similar study with isokinetic measurements regarding this subject, a difference in mean values of 10 Nm and standard deviation of 12 Nm were assumed for each group. The group sample sizes of 31 and 31 achieved a power of 0.90 to detect a difference of 10 Nm between the two groups with estimated group standard deviations of 12 for each group and with a significance level (alpha) of 0.05 using a two-sided, two-sample test. Considering the loss to follow-up, two patients were added to each group. Thus, recruitment will end after 33 patients were assigned to either groups. All data will be calculated as mean and standard deviation. The Student's t-test will be used for statistical analysis of the patient data. Statistical calculations will be performed with SPSS 22.0 software (IBM SPSS Statistics for Windows, Version 22.0. Armonk, NY: IBM Corp.). A value of p< 0.05 will be considered statistically significant. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04419311
Study type Interventional
Source Aksaray University Training and Research Hospital
Contact
Status Completed
Phase N/A
Start date January 19, 2017
Completion date March 30, 2018

See also
  Status Clinical Trial Phase
Recruiting NCT03895489 - Effectiveness of the Journey Total Knee Arthroplasty Versus Two Standard of Care Total Knee Arthroplasty Prostheses N/A
Completed NCT03660943 - A Clinical Study to Test Efficacy and Safety of Repeat Doses of CNTX-4975-05 in Patients With Osteoarthritis Knee Pain Phase 3
Completed NCT04531969 - Comparison of Outpatient and Inpatient Spa Therapy N/A
Completed NCT02848027 - Correlating the Osteoarthritic Knee Microenvironment to Clinical Outcome After Treatment With Regenexx®SD Treatment Phase 3
Completed NCT05160246 - The Instant Effect of Kinesiology Taping in Patients With Knee OA N/A
Recruiting NCT06080763 - Biomechanics and Clinical Outcomes in Responders and Non-Responders
Completed NCT03643588 - The Comparison of HYAJOINT Plus and Hyalgan Hyaluronan Supplement for Knee Osteoarthritis Pain N/A
Active, not recruiting NCT05100225 - Efficacy and Safety Trial of PTP-001 (MOTYS) for Symptomatic Knee Osteoarthritis Phase 2
Active, not recruiting NCT04061733 - New Hydroxyethyl Cellulose Hydrogel for the Treatment of the Pain of Knee Arthrosis N/A
Completed NCT04051489 - A Novel Smartphone Application for "Smart" Knee Osteoarthritis Trials
Recruiting NCT05546541 - Epidemiology and Nutrition
Recruiting NCT05447767 - Prediction AlgoriThm for regeneraTive Medicine Approach in knEe OA: New Decision-making Process Based on Patient pRofiliNg Phase 2
Not yet recruiting NCT04448106 - Autologous Adipose Tissue-Derived Mesenchymal Stem Cells (AdMSCs) for Osteoarthritis Phase 2
Not yet recruiting NCT03225911 - Effect of a Lateral Wedge Insole and Simple Knee Sleeve in Individuals With Knee Osteoarthritis N/A
Completed NCT05070871 - A Clinical Trial Investigating the Effect of Salmon Bone Meal on Osteoarthritis Among Men and Women N/A
Completed NCT05703087 - Positive Cueing in Knee Arthroplasty. N/A
Not yet recruiting NCT06042426 - Effects of Perioperative Intravenous Dexamethasone in Clinical Outcomes After Total Knee Arthroplasty in a Hispanic Population Phase 4
Terminated NCT02909257 - Motor-Sparing Femoral Nerve Block Dose Phase 4
Completed NCT02881775 - Immediate Effects of rTMS on Excitability of the Quadriceps With Knee Osteoarthritis N/A
Completed NCT02905747 - The Effect of Medical Exercise Therapy on Pain, Function and Physical Activity in Patients With Knee Osteoarthritis N/A