Clinical Trials Logo

Clinical Trial Summary

The purpose of this study is to conduct a prospective randomized clinical trial to compare the accuracy of prosthesis, radiographic alignment, total blood loss, the risk of venous thromboembolism between pinless-navigated total knee arthroplasty (TKA) and traditional TKA.


Clinical Trial Description

Minimal invasive surgery total knee arthroplasty (MIS-TKA) is an excellent surgical procedure for patients with end-stage knee diseases and can reduce the postoperative complications compared with traditional TKA procedures.

However, MIS-TKA procedures require a long learning curve to avoid malposition of prosthesis. In previous studies have demonstrated that the position of prosthesis and the postoperative mechanical axis are critical factors of outcome. Malposition of prosthesis and deviation more than 3 degrees of mechanical axis will lead to asymmetrical tibia-femoral tracking between prosthesis with the wear of linear, and increase the incidence of prosthesis loosening.

Computer navigation assisted system has been used in TKA procedures for more than one decade and has been proven to improve the accuracy of prosthesis placement and postoperative mechanical alignment. Moreover, navigated TKA avoids the use of intramedullary guide and preserve the medullary cavity of femur, so the risks of bleeding and venous thromboembolism are reduced. However, traditional navigation system requires additional procedure to set reference arrays with pin fixation of femur and tibia. Pin wound complications including bleeding, infection, and iatrogenic fracture were reported. Moreover, traditional navigation system requires conventional TKA approach in which the wound length of the knee will be as long as 15 to 20 cm. Therefore a combination of new navigation system with a MIS technique to perform TKA procedure is required The new pinless navigated system for TKA procedures has been developed, as the navigation tools were fixed in the surgical field without additional pin wounds. This advantage meets the rationale of MIS-TKA to take care of both minimal invasive procedures and accuracy of prosthesis placement. Therefore, the investigators want to investigate the application of this pinless navigation system in MIS-TKA procedures.

Our purpose is to conduct a prospective randomized clinical trial to compare the accuracy of prosthesis, radiographic alignment, total blood loss, the risk of venous thromboembolism between pinless-navigated MIS-TKA and traditional MIS-TKA.

Material and Methods:

The investigators plan to enroll 100 patients who plan to undergo unilateral primary MIS-TKA and will be randomly assigned into two groups. The first group (50 patients) will be treated by pinless-navigation (Stryker, OrthoMap Express Knee Navigation) MIS-TKA, and the second group (50 patients) will undergo traditional MIS-TKA.

The investigators will record the surgical wound length, surgical time cost and calculate daily hemoglobin drainage and total blood loss after TKA procedures for all patients. At 3 months after operation, the whole leg scanography, AP and lat view of knee radiography will be take and the mechanical alignment (MA), anatomic alignment (AA), femoral bowing angle (FBA), and coronal femoral-component angle (CFA), coronal tibia-component angle (CTA) in coronary view and sagittal femoral component angle (SFA), sagittal tibial component angle (STA) in lateral view will be measured. The operating time and surgical wound length in knee full extension will be recorded. All complications including bleedings, wound complications, venous thromboembolism will be recorded.

Study year: one year Expecting Result The investigators anticipate that the position of prosthesis in pinless-navigated MIS-TKA is more accurate or equal to traditional MIS-TKA group. And the total blood loss in pinless-navigated MIS-TKA is less than traditional MIS-TKA group. The complication rate is similar between the two groups ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04235283
Study type Interventional
Source Chang Gung Memorial Hospital
Contact Shih-Hsiang Yen, MD
Phone 886-7-7317123
Email yswings@cgmh.org.tw
Status Recruiting
Phase N/A
Start date May 1, 2019
Completion date December 31, 2020

See also
  Status Clinical Trial Phase
Recruiting NCT03895489 - Effectiveness of the Journey Total Knee Arthroplasty Versus Two Standard of Care Total Knee Arthroplasty Prostheses N/A
Completed NCT03660943 - A Clinical Study to Test Efficacy and Safety of Repeat Doses of CNTX-4975-05 in Patients With Osteoarthritis Knee Pain Phase 3
Completed NCT04531969 - Comparison of Outpatient and Inpatient Spa Therapy N/A
Completed NCT02848027 - Correlating the Osteoarthritic Knee Microenvironment to Clinical Outcome After Treatment With Regenexx®SD Treatment Phase 3
Completed NCT05160246 - The Instant Effect of Kinesiology Taping in Patients With Knee OA N/A
Recruiting NCT06080763 - Biomechanics and Clinical Outcomes in Responders and Non-Responders
Completed NCT03643588 - The Comparison of HYAJOINT Plus and Hyalgan Hyaluronan Supplement for Knee Osteoarthritis Pain N/A
Active, not recruiting NCT05100225 - Efficacy and Safety Trial of PTP-001 (MOTYS) for Symptomatic Knee Osteoarthritis Phase 2
Active, not recruiting NCT04061733 - New Hydroxyethyl Cellulose Hydrogel for the Treatment of the Pain of Knee Arthrosis N/A
Completed NCT04051489 - A Novel Smartphone Application for "Smart" Knee Osteoarthritis Trials
Recruiting NCT05546541 - Epidemiology and Nutrition
Recruiting NCT05447767 - Prediction AlgoriThm for regeneraTive Medicine Approach in knEe OA: New Decision-making Process Based on Patient pRofiliNg Phase 2
Not yet recruiting NCT04448106 - Autologous Adipose Tissue-Derived Mesenchymal Stem Cells (AdMSCs) for Osteoarthritis Phase 2
Not yet recruiting NCT03225911 - Effect of a Lateral Wedge Insole and Simple Knee Sleeve in Individuals With Knee Osteoarthritis N/A
Completed NCT05070871 - A Clinical Trial Investigating the Effect of Salmon Bone Meal on Osteoarthritis Among Men and Women N/A
Completed NCT05703087 - Positive Cueing in Knee Arthroplasty. N/A
Not yet recruiting NCT06042426 - Effects of Perioperative Intravenous Dexamethasone in Clinical Outcomes After Total Knee Arthroplasty in a Hispanic Population Phase 4
Not yet recruiting NCT02854176 - Somatosensory Stimulation in Knee Osteoarthritis Phase 2
Completed NCT02944448 - A Study Evaluating Pain Relief and Safety of Orally Administered CR845 in Patients With Osteoarthritis of Hip or Knee Phase 2
Terminated NCT02909257 - Motor-Sparing Femoral Nerve Block Dose Phase 4