Clinical Trials Logo

Clinical Trial Summary

The purpose of this scientific study is to clarify whether there is a relationship between the appearance of radiolucent lines in bone-cement interphase of the tibial component of the different models of the Oxford Uni Knee prosthesis and poor prognosis of these prostheses. This will be accomplished in a se-ries of three different Oxford Uni Knees.


Clinical Trial Description

The purpose of this scientific study is to clarify whether there is a relationship between the appearance of radiolucent lines in bone-cement interphase of the tibial component of the different models of the Oxford Uni Knee prosthesis and poor prognosis of these prostheses. This will be accomplished in a series of three different Oxford Uni Knees by studying: 1. Three way randomized comparison of migration (prosthetic fixation) by Model Based RSA with three different Oxford Uni Knee prosthesis (both tibial trays and femoral components will be assessed). 2. Fluoroscopy (screening) roentgenograms for determination of RLL around the tibial component and "overhang" of the tibial trays. 3. Changes in periprosthetic bone mineral density between the three randomized groups evaluated in the proximal tibia and distal femur on the surgical side and on the unaffected tibial condyle area (BMD). 4. Clinical function of the Uni Knee evaluated by a score system using a recent Danish adaptation of the Oxford Knee Score that consists of a questionnaire filled-out by the patient with 12 simple questions on pre-and postoperative assessment of the ADL. 5. Analysis of wear of the mobile polyethylene (meniscus) including a methodical study as to whether the technique requires weightbearing (standing) stereoroentgenograms or whether non-weightbearing stereoroentgenograms can be used (assessed with Model Based RSA). 6. If a fast bone-remodeling increases the risk of aseptic loosening (histomorphometric results combined with RSA results and possible revision) 7. Increased risk of aseptic loosening with cemented (two designs) compared to uncemented im-plants. 8. If bone-remodeling of the proximal tibia is dependent on gender and age. The study would be considered a success if all designs of the prostheses are firmly fixed and remain so during the entire period of study, that is, no increasing migration is seen using RSA. It would be a success if the appearance of RLL beneath the implant in the proximal tibia is unrelated to bone loss and prosthesis migration. The hypotheses are: 1. RLL in relation to the tibial component is unimportant for fixation of the Oxford Uni Knee as assessed with DEXA and RSA. 2. There is very little wear of the polyethylene in the course of a 5 year follow-up as assessed with RSA. 3. The femoral component is expected to remain fixed throughout the entire period of follow-up. 4. Function assessment as ROM (range of motion) after UKA is satisfactory and generally better than after TKA. 5. All three prosthetic designs are expected to migrate minimally and remain fixed throughout the follow-up period, but the uncemented design is expected to be superior to the cemented design. 6. No difference in clinical outcome between the three prosthetic types. 7. The bone-remodeling rate in the medial periarticular tibia bone increases the risk of aseptic loosening. The primary parameters of effect are RLL, RSA and DEXA. The secondary parameters of effect are bone-remodeling, wear analysis, Oxford Knee Score (ADL) and ROM. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT00679120
Study type Interventional
Source University of Aarhus
Contact
Status Active, not recruiting
Phase N/A
Start date May 2009
Completion date August 2024

See also
  Status Clinical Trial Phase
Recruiting NCT03895489 - Effectiveness of the Journey Total Knee Arthroplasty Versus Two Standard of Care Total Knee Arthroplasty Prostheses N/A
Completed NCT03660943 - A Clinical Study to Test Efficacy and Safety of Repeat Doses of CNTX-4975-05 in Patients With Osteoarthritis Knee Pain Phase 3
Completed NCT04531969 - Comparison of Outpatient and Inpatient Spa Therapy N/A
Completed NCT02848027 - Correlating the Osteoarthritic Knee Microenvironment to Clinical Outcome After Treatment With Regenexx®SD Treatment Phase 3
Completed NCT05160246 - The Instant Effect of Kinesiology Taping in Patients With Knee OA N/A
Recruiting NCT06080763 - Biomechanics and Clinical Outcomes in Responders and Non-Responders
Completed NCT03643588 - The Comparison of HYAJOINT Plus and Hyalgan Hyaluronan Supplement for Knee Osteoarthritis Pain N/A
Active, not recruiting NCT05100225 - Efficacy and Safety Trial of PTP-001 (MOTYS) for Symptomatic Knee Osteoarthritis Phase 2
Active, not recruiting NCT04061733 - New Hydroxyethyl Cellulose Hydrogel for the Treatment of the Pain of Knee Arthrosis N/A
Completed NCT04051489 - A Novel Smartphone Application for "Smart" Knee Osteoarthritis Trials
Recruiting NCT05546541 - Epidemiology and Nutrition
Recruiting NCT05447767 - Prediction AlgoriThm for regeneraTive Medicine Approach in knEe OA: New Decision-making Process Based on Patient pRofiliNg Phase 2
Not yet recruiting NCT04448106 - Autologous Adipose Tissue-Derived Mesenchymal Stem Cells (AdMSCs) for Osteoarthritis Phase 2
Not yet recruiting NCT03225911 - Effect of a Lateral Wedge Insole and Simple Knee Sleeve in Individuals With Knee Osteoarthritis N/A
Completed NCT05070871 - A Clinical Trial Investigating the Effect of Salmon Bone Meal on Osteoarthritis Among Men and Women N/A
Completed NCT05703087 - Positive Cueing in Knee Arthroplasty. N/A
Not yet recruiting NCT06042426 - Effects of Perioperative Intravenous Dexamethasone in Clinical Outcomes After Total Knee Arthroplasty in a Hispanic Population Phase 4
Terminated NCT02909257 - Motor-Sparing Femoral Nerve Block Dose Phase 4
Completed NCT02944448 - A Study Evaluating Pain Relief and Safety of Orally Administered CR845 in Patients With Osteoarthritis of Hip or Knee Phase 2
Not yet recruiting NCT02854176 - Somatosensory Stimulation in Knee Osteoarthritis Phase 2