Osteoarthritis, Hip Clinical Trial
Official title:
Accuracy in aChieving Optimum reconstrUction: Measured- vs. Navigation- Techniques in Hip Arthroplasty
Accurate reconstruction of the native hip parameters following total hip arthroplasty is associated with improved outcome. In order to improve ability for optimum reconstruction, 3-D templating software can be utilized that provide detailed information regarding native anatomy. In order to achieve reconstruction within acceptable parameters as per pre-operative plan, some surgeons propose the use of intra-operative devices that measure component orientation and joint reconstruction ("Measured-THA"), whilst others propose the use of navigation tools ("Navigation-THA). Both techniques have shown superiority compared to the most commonly used "freehand" technique, but no prior study has assessed for superiority between these 2 techniques. Furthermore, to-date assessment of post-operative reconstruction has not been tested in detail as post-THA assessments are based on radiographs which provide incomplete, 2-dimensional, assessments and are lacking the important axial plane reconstruction parameters. The aims of this prospective, randomized, trial are to 1. appraise the ability to achieve the pre-operative 3-D plan (as per FormusLab) through a comparison of pre-op plan to post-operative reconstruction; 2. compare ability to accurately reconstruct hip following THA between "navigated-" (IntelliJoint®) and "measured-" techniques; and in doing so it will also 3. assess the accuracy of the intra-operative assessments of reconstruction through a comparison of objective (i.e. measured) intra-operative assessments with the post-operative reconstructions achieved.
Status | Not yet recruiting |
Enrollment | 100 |
Est. completion date | September 1, 2024 |
Est. primary completion date | July 1, 2024 |
Accepts healthy volunteers | No |
Gender | All |
Age group | N/A and older |
Eligibility | Inclusion Criteria: - Patients who are signed for a THA for primary or secondary osteoarthritis without overt deformity that would require revision type implants and with good enough bone quality to be listed for uncemented component implantation. Exclusion Criteria: - Secondary OA due to Dysplasia (Hartofilakidis >1) - Avascular necrosis of the hip with destruction of joint structure - Sequelae of Pediatric deformity with abnormal anatomy - Cemented fixation of femur or acetabulum - Previous arthroplasty-type procedure - Previous septic arthritis of the hip |
Country | Name | City | State |
---|---|---|---|
n/a |
Lead Sponsor | Collaborator |
---|---|
Ottawa Hospital Research Institute | FormusLab |
Agarwal S, Eckhard L, Walter WL, Peng A, Hatton A, Donnelly B, de Steiger R. The Use of Computer Navigation in Total Hip Arthroplasty Is Associated with a Reduced Rate of Revision for Dislocation: A Study of 6,912 Navigated THA Procedures from the Australian Orthopaedic Association National Joint Replacement Registry. J Bone Joint Surg Am. 2021 Oct 20;103(20):1900-1905. doi: 10.2106/JBJS.20.00950. — View Citation
Amuwa C, Dorr LD. The combined anteversion technique for acetabular component anteversion. J Arthroplasty. 2008 Oct;23(7):1068-70. doi: 10.1016/j.arth.2008.04.025. Epub 2008 Jun 4. — View Citation
Barrack RL, Krempec JA, Clohisy JC, McDonald DJ, Ricci WM, Ruh EL, Nunley RM. Accuracy of acetabular component position in hip arthroplasty. J Bone Joint Surg Am. 2013 Oct 2;95(19):1760-8. doi: 10.2106/JBJS.L.01704. — View Citation
Beverland DE, O'Neill CK, Rutherford M, Molloy D, Hill JC. Placement of the acetabular component. Bone Joint J. 2016 Jan;98-B(1 Suppl A):37-43. doi: 10.1302/0301-620X.98B1.36343. — View Citation
Blumenfeld TJ. Pearls: Clinical Application of Ranawat's Sign. Clin Orthop Relat Res. 2017 Jul;475(7):1789-1790. doi: 10.1007/s11999-017-5376-8. Epub 2017 May 11. — View Citation
Bonnin MP, Archbold PH, Basiglini L, Fessy MH, Beverland DE. Do we medialise the hip centre of rotation in total hip arthroplasty? Influence of acetabular offset and surgical technique. Hip Int. 2012 Jul-Aug;22(4):371-8. doi: 10.5301/HIP.2012.9350. — View Citation
Bosker BH, Verheyen CC, Horstmann WG, Tulp NJ. Poor accuracy of freehand cup positioning during total hip arthroplasty. Arch Orthop Trauma Surg. 2007 Jul;127(5):375-9. Epub 2007 Feb 13. — View Citation
Callanan MC, Jarrett B, Bragdon CR, Zurakowski D, Rubash HE, Freiberg AA, Malchau H. The John Charnley Award: risk factors for cup malpositioning: quality improvement through a joint registry at a tertiary hospital. Clin Orthop Relat Res. 2011 Feb;469(2):319-29. doi: 10.1007/s11999-010-1487-1. — View Citation
Christ A, Ponzio D, Pitta M, Carroll K, Muir JM, Sculco PK. Minimal Increase in Total Hip Arthroplasty Surgical Procedural Time with the Use of a Novel Surgical Navigation Tool. Open Orthop J. 2018 Sep 28;12:389-395. doi: 10.2174/1874325001812010389. eCollection 2018. — View Citation
Dorr LD, Hishiki Y, Wan Z, Newton D, Yun A. Development of imageless computer navigation for acetabular component position in total hip replacement. Iowa Orthop J. 2005;25:1-9. — View Citation
Dorr LD, Malik A, Dastane M, Wan Z. Combined anteversion technique for total hip arthroplasty. Clin Orthop Relat Res. 2009 Jan;467(1):119-27. doi: 10.1007/s11999-008-0598-4. Epub 2008 Nov 1. — View Citation
Dorr LD, Wan Z, Malik A, Zhu J, Dastane M, Deshmane P. A comparison of surgeon estimation and computed tomographic measurement of femoral component anteversion in cementless total hip arthroplasty. J Bone Joint Surg Am. 2009 Nov;91(11):2598-604. doi: 10.2106/JBJS.H.01225. — View Citation
Fang CJ, Shaker JM, Ward DM, Jawa A, Mattingly DA, Smith EL. Financial Burden of Revision Hip and Knee Arthroplasty at an Orthopedic Specialty Hospital: Higher Costs and Unequal Reimbursements. J Arthroplasty. 2021 Aug;36(8):2680-2684. doi: 10.1016/j.arth.2021.03.044. Epub 2021 Mar 23. — View Citation
Grammatopoulos G, Thomas GE, Pandit H, Beard DJ, Gill HS, Murray DW. The effect of orientation of the acetabular component on outcome following total hip arthroplasty with small diameter hard-on-soft bearings. Bone Joint J. 2015 Feb;97-B(2):164-72. doi: 10.1302/0301-620X.97B2.34294. — View Citation
Gross AE, Safir OA, Kuzyk PRT, Sculco PK, Wolfstadt J, Girardi BL, et al. Optimizing leg length and cup position: A surgical navigation tool. Seminars in Arthroplasty. 2018;29(3):157-60.
Gupta R, Pathak P, Singh R, Majumdar KP. Double-Stitch Technique: A Simple and Effective Method to Minimize Limb Length Discrepancy after Total Hip Arthroplasty. Indian J Orthop. 2019 Jan-Feb;53(1):169-173. doi: 10.4103/ortho.IJOrtho_188_18. — View Citation
Hill JC, Archbold HA, Diamond OJ, Orr JF, Jaramaz B, Beverland DE. Using a calliper to restore the centre of the femoral head during total hip replacement. J Bone Joint Surg Br. 2012 Nov;94(11):1468-74. doi: 10.1302/0301-620X.94B11.29144. — View Citation
Hu X, Zheng N, Chen Y, Dai K, Dimitriou D, Li H, Tsai TY. Optimizing the Femoral Offset for Restoring Physiological Hip Muscle Function in Patients With Total Hip Arthroplasty. Front Bioeng Biotechnol. 2021 Mar 30;9:645019. doi: 10.3389/fbioe.2021.645019. eCollection 2021. — View Citation
Innmann MM, Maier MW, Streit MR, Grammatopoulos G, Bruckner T, Gotterbarm T, Merle C. Additive Influence of Hip Offset and Leg Length Reconstruction on Postoperative Improvement in Clinical Outcome After Total Hip Arthroplasty. J Arthroplasty. 2018 Jan;33(1):156-161. doi: 10.1016/j.arth.2017.08.007. Epub 2017 Aug 12. — View Citation
Jacob I, Benson J, Shanaghan K, Gonzalez Della Valle A. Acetabular positioning is more consistent with the use of a novel miniature computer-assisted device. Int Orthop. 2020 Mar;44(3):429-435. doi: 10.1007/s00264-020-04484-2. Epub 2020 Jan 22. — View Citation
Kievit AJ, Dobbe JGG, Mallee WH, Blankevoort L, Streekstra GJ, Schafroth MU. Accuracy of cup placement in total hip arthroplasty by means of a mechanical positioning device: a comprehensive cadaveric 3d analysis of 16 specimens. Hip Int. 2021 Jan;31(1):58-65. doi: 10.1177/1120700019874822. Epub 2019 Sep 11. — View Citation
Koper MC, Reijman M, van Es EM, Waarsing JH, Koot HWJ, Keizer SB, Jansen I, van Biezen FC, Verhaar JAN, Bos PK. No added value for Computer-Assisted surgery to improve femoral component positioning and Patient Reported Outcomes in Hip Resurfacing Arthroplasty; a multi-center randomized controlled trial. BMC Musculoskelet Disord. 2019 Oct 25;20(1):473. doi: 10.1186/s12891-019-2883-7. — View Citation
Lee YK, Kim JW, Kim TY, Ha YC, Koo KH. Validity of the intra-operative measurement of stem anteversion and factors for the erroneous estimation in cementless total hip arthroplasty using postero-lateral approach. Orthop Traumatol Surg Res. 2018 May;104(3):341-346. doi: 10.1016/j.otsr.2017.11.023. Epub 2018 Feb 16. — View Citation
Meermans G, Goetheer-Smits I, Lim RF, Van Doorn WJ, Kats J. The difference between the radiographic and the operative angle of inclination of the acetabular component in total hip arthroplasty: use of a digital protractor and the circumference of the hip to improve orientation. Bone Joint J. 2015 May;97-B(5):603-10. doi: 10.1302/0301-620X.97B5.34781. — View Citation
Meermans G, Van Doorn WJ, Koenraadt K, Kats J. The use of the transverse acetabular ligament for determining the orientation of the components in total hip replacement: a randomised controlled trial. Bone Joint J. 2014 Mar;96-B(3):312-8. doi: 10.1302/0301-620X.96B3.32989. — View Citation
Merle C, Innmann MM, Waldstein W, Pegg EC, Aldinger PR, Gill HS, Murray DW, Grammatopoulos G. High Variability of Acetabular Offset in Primary Hip Osteoarthritis Influences Acetabular Reaming-A Computed Tomography-Based Anatomic Study. J Arthroplasty. 2019 Aug;34(8):1808-1814. doi: 10.1016/j.arth.2019.03.065. Epub 2019 Apr 1. — View Citation
Minoda Y, Ohzono K, Aihara M, Umeda N, Tomita M, Hayakawa K. Are acetabular component alignment guides for total hip arthroplasty accurate? J Arthroplasty. 2010 Sep;25(6):986-9. doi: 10.1016/j.arth.2009.07.016. Epub 2009 Oct 17. — View Citation
Mitsutake R, Tanino H, Nishida Y, Higa M, Ito H. A simple angle-measuring instrument for measuring cemented stem anteversion during total hip arthroplasty. BMC Musculoskelet Disord. 2020 Feb 19;21(1):113. doi: 10.1186/s12891-020-3142-7. — View Citation
Murray DW. The definition and measurement of acetabular orientation. J Bone Joint Surg Br. 1993 Mar;75(2):228-32. — View Citation
Ogawa T, Takao M, Hamada H, Sakai T, Sugano N. Soft tissue tension is four times lower in the unstable primary total hip arthroplasty. Int Orthop. 2018 Sep;42(9):2059-2065. doi: 10.1007/s00264-018-3908-9. Epub 2018 Mar 27. — View Citation
Paprosky WG, Muir JM. Intellijoint HIP(®): a 3D mini-optical navigation tool for improving intraoperative accuracy during total hip arthroplasty. Med Devices (Auckl). 2016 Nov 18;9:401-408. eCollection 2016. — View Citation
Parvizi J, Benson JR, Muir JM. A new mini-navigation tool allows accurate component placement during anterior total hip arthroplasty. Med Devices (Auckl). 2018 Mar 22;11:95-104. doi: 10.2147/MDER.S151835. eCollection 2018. — View Citation
Pongkunakorn A, Chatmaitri S, Diewwattanawiwat K. Use of smartphone to improve acetabular component positioning in total hip athroplasty: A comparative clinical study. J Orthop Surg (Hong Kong). 2019 Jan-Apr;27(1):2309499019825578. doi: 10.1177/2309499019825578. Erratum in: J Orthop Surg (Hong Kong). 2019 Jan-Apr;27(1):2309499019834501. — View Citation
Schiffner E, Latz D, Jungbluth P, Grassmann JP, Tanner S, Karbowski A, Windolf J, Schneppendahl J. Is computerised 3D templating more accurate than 2D templating to predict size of components in primary total hip arthroplasty? Hip Int. 2019 May;29(3):270-275. doi: 10.1177/1120700018776311. Epub 2018 May 20. — View Citation
Schwarzkopf R, Muir JM, Paprosky WG, Seymour S, Cross MB, Vigdorchik JM. Quantifying Pelvic Motion During Total Hip Arthroplasty Using a New Surgical Navigation Device. J Arthroplasty. 2017 Oct;32(10):3056-3060. doi: 10.1016/j.arth.2017.04.046. Epub 2017 May 4. — View Citation
Shon WY, Baldini T, Peterson MG, Wright TM, Salvati EA. Impingement in total hip arthroplasty a study of retrieved acetabular components. J Arthroplasty. 2005 Jun;20(4):427-35. — View Citation
Singh V, Realyvasquez J, Simcox T, Rozell JC, Schwarzkopf R, Davidovitch RI. Robotics Versus Navigation Versus Conventional Total Hip Arthroplasty: Does the Use of Technology Yield Superior Outcomes? J Arthroplasty. 2021 Aug;36(8):2801-2807. doi: 10.1016/j.arth.2021.02.074. Epub 2021 Mar 5. — View Citation
Snijders T, van Gaalen SM, de Gast A. Precision and accuracy of imageless navigation versus freehand implantation of total hip arthroplasty: A systematic review and meta-analysis. Int J Med Robot. 2017 Dec;13(4). doi: 10.1002/rcs.1843. Epub 2017 May 29. Review. — View Citation
Steppacher SD, Kowal JH, Murphy SB. Improving cup positioning using a mechanical navigation instrument. Clin Orthop Relat Res. 2011 Feb;469(2):423-8. doi: 10.1007/s11999-010-1553-8. — View Citation
* Note: There are 39 references in all — Click here to view all references
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | Change in Pain Assessment - Oxford Hip Score | The Oxford Hip Score will be given to patients to assess subjective measures of hip pain. Scores for each question from 0 to 4 with 4 being the best outcome. This method, when summed, produces overall scores running from 0 to 48 with 48 being the best outcome | once pre-operatively and once one-year post-operatively | |
Primary | Change in mobility, self-care, usual activities, pain/discomfort and anxiety/depression- EuroQol | the EuroQol (EQ-5D-5L) will be given to patients to assess subjective measures mobility, self-care, usual activities, pain/discomfort and anxiety/depression.
Each dimension in the EQ-5D-5L has five response levels: no problems (Level 1); slight; moderate; severe; and extreme problems (Level 5). The maximum score of 1 indicates the best health state, by contrast with the scores of individual questions, where higher scores indicate more severe or frequent problems. |
once pre-operatively and once one-year post-operatively | |
Primary | Change in physical, mental, and social health- PROMIS Global-10 | the PROMIS Global-10 will be given to patients to assess subjective measures of physical, mental and social health. It is a 10-item patient-reported questionnaire in which the response options are presented as 5-point (as well as a single 11-point) rating scales. The results of the questions are used to calculate two summary scores: a Global Physical Health Score and a Global Mental Health score. Higher scores indicate worse physical and mental health | once pre-operatively and once one-year post-operatively | |
Primary | Adverse Events | Serious adverse events will be monitored. This includes:
Wound complication Dislocation Fracture Infection Re-operation Revision surgery |
90 days post-operatively | |
Secondary | Accuracy of reconstruction (in mm) | A measure (in mm) of how close the planned to actual reconstruction using the aforementioned reconstruction parameters. This will be assessed using:
Acetabular component orientation Accuracy of acetabular component orientation o Accuracy of femoral version restoration Combined version of arthroplasty in degrees Accuracy of combined version restoration Femoral Offset in mm o Accuracy of achieving femoral offset Acetabular offset in mm o Accuracy of achieving acetabular offset Total offset in mm o Accuracy of achieving total offset Leg Length in mm o Accuracy of achieving leg length |
post-operatively (within one week post-operatively) | |
Secondary | Comparison of margin of error | This outcome will measure what the margin of error is between intra-operatively measured values and those determined from the post-operative CT scan. This will be done using statistical analysis of data for patients in both study arms. | Through study completion, an average of 1 year | |
Secondary | Accuracy of reconstruction on outcome | This outcome measure will assess the accuracy of reconstruction correlate with outcome (adverse events and PROMs). This will be done by analyzing accuracy as depicted by the variables in outcome measure 5, and how these measures of accuracy correlate to patient reported outcome measure scores and rates of adverse events | Through study completion, an average of 1 year | |
Secondary | Accuracy of reconstruction (in degrees) | A measure (in degrees) of how close the planned to actual reconstruction using the aforementioned reconstruction parameters. This will be assessed using:
Acetabular component orientation (Radiographic inclination/anteversion in degrees as per Murray) Accuracy of acetabular component orientation (i.e. deviation from target - aim for deviation of < ±5°) ? Femoral Component Version in degrees Accuracy of femoral version restoration (aim for version difference to be less than ±5° from pre-operative plan) ? Combined version of arthroplasty in degrees Accuracy of combined version restoration (sum of acetabular and femoral version; aim for combined version to be less than ±10° from pre-operative plan) |
post-operatively (within one week post-operatively) |
Status | Clinical Trial | Phase | |
---|---|---|---|
Active, not recruiting |
NCT05773261 -
Clinical Investigation Comparing Two Different Ultra-porous Coated Surfaces of Uncemented Cups
|
N/A | |
Recruiting |
NCT05223777 -
KINCISE™ Surgical Automated System in Total Hip Arthroplasty (THA)
|
N/A | |
Recruiting |
NCT04731077 -
Avenir Complete Post-Market Clinical Follow-Up Study
|
N/A | |
Not yet recruiting |
NCT04448106 -
Autologous Adipose Tissue-Derived Mesenchymal Stem Cells (AdMSCs) for Osteoarthritis
|
Phase 2 | |
Completed |
NCT05070871 -
A Clinical Trial Investigating the Effect of Salmon Bone Meal on Osteoarthritis Among Men and Women
|
N/A | |
Not yet recruiting |
NCT06162195 -
The ACTIVE Trial: A Prospective Randomised Control Trial Of The H1 Implant Versus Total Hip Replacement
|
N/A | |
Withdrawn |
NCT02743208 -
Evaluation of a Short Femoral Stem in Total Hip Arthroplasty
|
N/A | |
Completed |
NCT02944448 -
A Study Evaluating Pain Relief and Safety of Orally Administered CR845 in Patients With Osteoarthritis of Hip or Knee
|
Phase 2 | |
Active, not recruiting |
NCT02229279 -
Evaluation of Teleconsulting on Rehabilitation After Hip and Knee Surgical Procedures
|
N/A | |
Active, not recruiting |
NCT02851992 -
A Prospective Study to Evaluate Long-term Clinical Outcomes of the GTS Cementless Femoral Stem
|
N/A | |
Completed |
NCT01618708 -
A Study of the Safety and Effectiveness of Synvisc-One® (Hylan G-F 20) in Patients With Primary Osteoarthritis of the Hip
|
N/A | |
Completed |
NCT01700933 -
Dose-response: Exercise Therapy on Hip Osteoarthritis
|
N/A | |
Completed |
NCT01214954 -
Early Rehabilitation After Total Hip Replacement
|
N/A | |
Active, not recruiting |
NCT00294424 -
Study on Costs and Effects of Waiting Time in Total Hip and Knee Replacements
|
N/A | |
Terminated |
NCT00588861 -
Total Hip Replacement With the Answer® Hip Stem and Ranawat/Burnstein® Shell Using Simplex® or Palacos® Bone Cement
|
N/A | |
Withdrawn |
NCT05054595 -
Audio-Recorded vs. Nurse-Led Brief Mindfulness-Based Intervention
|
N/A | |
Terminated |
NCT00973141 -
A Dose-ranging Study of the Safety and Effectiveness of JNJ-42160443 as add-on Treatment in Patients With Osteoarthritis-related Pain
|
Phase 2 | |
Recruiting |
NCT05014113 -
H-28 DELTA ST-C and Minima Retrospective Study.
|
||
Completed |
NCT01066936 -
Mini Stem DEXA (Dual Energy X-ray Absorptiometry)
|
||
Recruiting |
NCT06185036 -
Histological Validation of dGEMRIC Indices as a Quantitative Biomarker for Cartilage Damage in the Hip Joint
|