Clinical Trials Logo

Clinical Trial Details — Status: Active, not recruiting

Administrative data

NCT number NCT04646096
Other study ID # AHI-003
Secondary ID
Status Active, not recruiting
Phase N/A
First received
Last updated
Start date January 1, 2021
Est. completion date January 1, 2024

Study information

Verified date February 2023
Source American Hip Institute
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

The current study is a multi-center study to assess precision and accuracy of the robotic system with new software.


Description:

Robotic-arm assisted surgery aims to reduce errors and improve accuracy for implant position in total hip arthroplasty (THA). In THA implant positioning plays a pivotal role in good clinical outcomes and reduces long-term wear, therefore, technology has been developed to help surgeons achieve more accurate implant position consistently. Computer-assisted navigation provides surgeon with knowledge to help guide surgeons intra-operatively with some systems computed tomography (CT)-based, others fluoroscopy based, and others imageless systems. Computer navigation has been shown to accurately place components, but does not provide the ability for patient specific pre-operative planning that CT- based robotics allows. While some may argue that robotic-arm assisted THA is more accurate, others argue that the cost and learning curve associated with robotic-arm assisted THA is not more accurate with no long-term clinical benefits. Robotic arm-assisted THA has been shown to improve accuracy of component placement and reduce outliers. Kayani et al reviewed 100 cases performed by a single surgeon with 50 THAs performed manually and 50 robotic arm-assisted. In this study, Kayani did not find a learning curve associated with achieving accuracy using the robotic arm-assisted technology; however, there was a 12 case learning curve for both himself and his operating staff that increased operative time [9]. Nodzo et al evaluated the use of the robotic arm-assisted THA using post-operative CT scans and found that both the acetabular and femoral component position were significantly accurate when compared to the intra-op position. Kamara et al reviewed a single surgeon case series to assess acetabular accuracy and found that 76% of manual THAs were within the surgeons' target zone compared to 97% of his robotic arm-assisted THAs, concluding that adoption of robotic arm-assisted THA provided significant improvement in acetabular component positioning during THA. Similarly, Redmond et al found that although there was a learning curve associated with robotic arm-assisted THA, operative time decreased with experience and acetabular component outliers decreased suggesting that while there is a learning curve with robotic arm-assisted THA the clinical benefits are better implant positioning and decreased outliers. Illgen et al reported that the improved acetabular accuracy in robotic arm-assisted THA significantly reduced dislocation rates when compared to manual THA. Bukowski et al reported robotic arm-assisted THA clinical outcomes at a minimum of 1 year and found that patients who underwent a robotic arm-assisted THA has higher clinical outcomes compared to a manual group, however, there have been no large multicenter studies that assess clinical outcomes after robotic arm-assisted THA. In conjunction with numerous other patient-specific and surgical factors, such as age, sex, comorbidities, surgical approach, component selection, and impingement, component positioning is often cited as an important factor in optimizing THA stability. Lewinnek et al. defined the "safe zone" for component position as 40⸰±10⸰ of cup inclination and 15⸰±10⸰ of cup anteversion to minimize dislocation risk. However, recent studies have shown that not only do components continue to dislocate when placed in this zone, but that the majority of THA dislocations are positioned in this safe zone to begin with. Compounding this issue is the growing body of evidence showing that the acetabular component is not static in nature, as was the assumption with Lewinnek's safe zone, but rather dynamically changing with movement of the pelvis and spine during postural and positional changes. Alterations of the dynamic relationship between the hip, spine, and pelvis in patients with hip-spine pathology during movements such as transitioning from standing to sitting affects typical pelvic biomechanical accommodation, resulting in THA component impingement, instability, and dislocation. Therefore, patients with spinopelvic pathology secondary to arthritis, spinal fusion, or spinal deformity are more prone to dislocation and revision following primary THA. The standard modality for assessing hip component position postoperatively is a 2D anteroposterior radiograph, due to low radiation dose and low cost. However, hip replacement components are placed in a 3-dimensional pelvis and femur, and therefore an anteroposterior radiograph alone may not give accurate information on the anteversion of the acetabular or femoral component. Studies have shown that cup anteversion measured with radiographs can have serious deviations with a substantial error range (mean deviation +1.74°, range -16.6° to 29.8°). This is attributed to the fact that radiographs cannot control for pelvic rotation and/or tilt. Recently a limited number of studies have started to use the other imaging modalities for understanding pelvic tilt in patients undergoing hip arthroplasty.


Recruitment information / eligibility

Status Active, not recruiting
Enrollment 35
Est. completion date January 1, 2024
Est. primary completion date January 1, 2024
Accepts healthy volunteers No
Gender All
Age group 18 Years and older
Eligibility Inclusion Criteria: - Requires primary total hip arthroplasty surgery - Willing and able to comply with postoperative follow up requirements - at least 18 years of age - sign an IRB approved informed consent Exclusion Criteria: - body mass index >40 - Skeletally immature - patient with active infection or suspected latent infection in or about joint - bone stock inadequate for support or fixation of the prosthesis - Neuromuscular disorders, muscle atrophy, or vascular deficient in the affected limb - Ankylosing spondylitis

Study Design


Related Conditions & MeSH terms


Intervention

Device:
MAKO THA 4.0 System
Measure how the accuracy and precision of robotic arm-assisted total hip arthroplasty (THA) for placement accuracy of implant position in both the anterior and posterior approach.. The intervention will assess the precision of the MAKO system in placing hip components according to plan. It will compare hip angles executed by the Mako system intraoperatively with the 'gold standard' of 3D computer tomography (CT) scans. The postoperative CT scan can show the precision of the MAKO system by accurately determining the location of hip replacements in patients after surgery.

Locations

Country Name City State
United States American Hip Institute Des Plaines Illinois

Sponsors (3)

Lead Sponsor Collaborator
American Hip Institute Hospital for Special Surgery, New York, Stryker Orthopaedics

Country where clinical trial is conducted

United States, 

References & Publications (1)

Nodzo SR, Chang CC, Carroll KM, Barlow BT, Banks SA, Padgett DE, Mayman DJ, Jerabek SA. Intraoperative placement of total hip arthroplasty components with robotic-arm assisted technology correlates with postoperative implant position: a CT-based study. Bone Joint J. 2018 Oct;100-B(10):1303-1309. doi: 10.1302/0301-620X.100B10-BJJ-2018-0201.R1. — View Citation

Outcome

Type Measure Description Time frame Safety issue
Primary Computed Tomography scan. Placement accuracy of acetabular cup and femoral stem Using computed tomography to assess placement accuracy, Measured in degrees 6 weeks postoperatively
Secondary Pelvic tilt measured preoperatively and intraoperatively in sitting and standing positions Preoperatively and postoperatively at 6 weeks and 1 year
Secondary Virtual range-of-motion measured preoperatively and intraoperatively in sitting and standing positions using virtual range of motion impingement modeling Preoperatively and postoperatively at 6 weeks and 1 year
Secondary Patient satisfaction Measured in a scale of 0-10 to determine how satisfied a patient is with their procedure. A score of 10 indicates most satisfied, a score of 0 is least satisfied. 1 year postoperative
Secondary Harris Hip Score Questionnaire. A measure of functionality of the operated hip. Measured scale: 0-100. Lower score means worse functional outcome. preoperative and 1 year postoperative
Secondary Forgotten Joint Score Assess likelihood the patient has forgotten that they had a hip replacement. Measured scale: 0-100. Higher score means better feeling of normalcy. 1 year postoperative
Secondary Hip Disability and Osteoarthritis Outcome Score Assess pain and function. Measured scale: 0-100. Higher the score, the greater the outcome and patient experience. 1 year postoperative
See also
  Status Clinical Trial Phase
Active, not recruiting NCT05773261 - Clinical Investigation Comparing Two Different Ultra-porous Coated Surfaces of Uncemented Cups N/A
Recruiting NCT05223777 - KINCISE™ Surgical Automated System in Total Hip Arthroplasty (THA) N/A
Recruiting NCT04731077 - Avenir Complete Post-Market Clinical Follow-Up Study N/A
Not yet recruiting NCT04448106 - Autologous Adipose Tissue-Derived Mesenchymal Stem Cells (AdMSCs) for Osteoarthritis Phase 2
Completed NCT05070871 - A Clinical Trial Investigating the Effect of Salmon Bone Meal on Osteoarthritis Among Men and Women N/A
Not yet recruiting NCT06162195 - The ACTIVE Trial: A Prospective Randomised Control Trial Of The H1 Implant Versus Total Hip Replacement N/A
Withdrawn NCT02743208 - Evaluation of a Short Femoral Stem in Total Hip Arthroplasty N/A
Completed NCT02944448 - A Study Evaluating Pain Relief and Safety of Orally Administered CR845 in Patients With Osteoarthritis of Hip or Knee Phase 2
Active, not recruiting NCT02229279 - Evaluation of Teleconsulting on Rehabilitation After Hip and Knee Surgical Procedures N/A
Active, not recruiting NCT02851992 - A Prospective Study to Evaluate Long-term Clinical Outcomes of the GTS Cementless Femoral Stem N/A
Completed NCT01618708 - A Study of the Safety and Effectiveness of Synvisc-One® (Hylan G-F 20) in Patients With Primary Osteoarthritis of the Hip N/A
Completed NCT01700933 - Dose-response: Exercise Therapy on Hip Osteoarthritis N/A
Completed NCT01214954 - Early Rehabilitation After Total Hip Replacement N/A
Active, not recruiting NCT00294424 - Study on Costs and Effects of Waiting Time in Total Hip and Knee Replacements N/A
Terminated NCT00588861 - Total Hip Replacement With the Answer® Hip Stem and Ranawat/Burnstein® Shell Using Simplex® or Palacos® Bone Cement N/A
Withdrawn NCT05054595 - Audio-Recorded vs. Nurse-Led Brief Mindfulness-Based Intervention N/A
Terminated NCT00973141 - A Dose-ranging Study of the Safety and Effectiveness of JNJ-42160443 as add-on Treatment in Patients With Osteoarthritis-related Pain Phase 2
Recruiting NCT05014113 - H-28 DELTA ST-C and Minima Retrospective Study.
Completed NCT01066936 - Mini Stem DEXA (Dual Energy X-ray Absorptiometry)
Recruiting NCT06185036 - Histological Validation of dGEMRIC Indices as a Quantitative Biomarker for Cartilage Damage in the Hip Joint