Osteoarthritis, Hip Clinical Trial
Official title:
Prospective Evaluation of Fixation of the Prime Acetabular Cup
This is a prospective study to compare migration of the Microport Prime acetabular cup to a well-established acetabular cup design after total hip replacement. We will enroll 30 patients with the Prime cup and compare migration, function, pain and quality of life to a historical cohort of patients whom had a different cup used during surgery.
The gold standard for measurement of implant fixation over time is radiostereometric analysis (RSA). At the time of surgery, 0.8-1.0 mm Tantalum beads (typically n = 6-8 per region of interest) are inserted into the bone surrounding the implant of interest, and occasionally also into the polyethylene liner or insert of the implant. RSA exams are then acquired within the first 2 weeks post-operation, and again at 6 weeks, 3 months, 6 months, 1 year, and 2 years. Each exam involves a stereo x-ray acquisition with a calibration unit to reconstruct the 3D location of the implant relative to the marker beads. Across each exam, the migration of the implant relative to the marker beads is tracked compared to the baseline exam acquired within the first 2 weeks. RSA is extremely precise and accurate, and is able to track migrations on the order of 10's of microns. Large early migrations within the first 1-2 years post-operation are predictive of eventual implant loosening and failure. For acetabular cups, proximal migration of greater than 1.0 mm within the first 2 years post-operation is considered unacceptable, with cups migrating between 0.2 and 1.0 mm at risk of having a revision rate exceeding 5% at 10 years. An RSA study should be completed for any new implant under the principles of phased innovation in orthopaedics. This ensures the new device will achieve long-term, stable fixation prior to its widespread adoption. Many device manufacturers incorporate the results of the RSA migration study into their marketing material. The advantage of RSA is its high degree of accuracy and its well-established thresholds for implant migration, meaning a relatively small number of patients are required to provide meaningful results. Several joint replacement companies (Microport excluded) have previously released new products to the marketplace without RSA evaluation and these implants have later been identified as having ingrowth problems. The scientific aim of this study is to prove efficacy of ingrowth with a recently released implant. This study design will be a prospective cohort with a retrospective control group. The study will be conducted at a single centre (London Health Sciences Centre - University Hospital, London, Ontario, Canada) with all cases performed by a single, fellowship-trained high-volume surgeon. The study group will receive a Prime cementless acetabular cup (manufactured by Microport located in Arlington, Tennessee). All patients will also receive a cementless Profemur femoral stem with a 32 mm Cobalt Chromium femoral head, articulating on a highly crosslinked acetabular liner. The control group will be a previously published cohort that received the Reflection cementless acetabular cup with Roughcoat coating (Smith & Nephew, Memphis, TN). This is a well-established cup with long-term survivorship available in multiple registries, making it an ideal comparator. Demographic details will be recorded from each patient. Outcome scores will be collected pre-operatively and at each post-operative visit. Standard outcome scores at our centre are the Western and McMaster Universities Osteoarthritis Index (WOMAC), Short Form 12 (SF-12), and Harris Hip Score. At the time of surgery, n = 8 of 1.0 mm Tantalum beads will be inserted into the pelvis surrounding the acetabular cup. Patients will undergo post-operative supine RSA exams within 0-2 weeks (baseline exam) and at 6 weeks, 3 months, 6 months, 1 year, and 2 years, following standardized protocols. RSA exams will be conducted at Robarts with a member of the research team escorting participants over to Robarts for each required post-operative visit. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Active, not recruiting |
NCT05773261 -
Clinical Investigation Comparing Two Different Ultra-porous Coated Surfaces of Uncemented Cups
|
N/A | |
Recruiting |
NCT05223777 -
KINCISEā¢ Surgical Automated System in Total Hip Arthroplasty (THA)
|
N/A | |
Recruiting |
NCT04731077 -
Avenir Complete Post-Market Clinical Follow-Up Study
|
N/A | |
Not yet recruiting |
NCT04448106 -
Autologous Adipose Tissue-Derived Mesenchymal Stem Cells (AdMSCs) for Osteoarthritis
|
Phase 2 | |
Completed |
NCT05070871 -
A Clinical Trial Investigating the Effect of Salmon Bone Meal on Osteoarthritis Among Men and Women
|
N/A | |
Not yet recruiting |
NCT06162195 -
The ACTIVE Trial: A Prospective Randomised Control Trial Of The H1 Implant Versus Total Hip Replacement
|
N/A | |
Withdrawn |
NCT02743208 -
Evaluation of a Short Femoral Stem in Total Hip Arthroplasty
|
N/A | |
Completed |
NCT02944448 -
A Study Evaluating Pain Relief and Safety of Orally Administered CR845 in Patients With Osteoarthritis of Hip or Knee
|
Phase 2 | |
Active, not recruiting |
NCT02229279 -
Evaluation of Teleconsulting on Rehabilitation After Hip and Knee Surgical Procedures
|
N/A | |
Active, not recruiting |
NCT02851992 -
A Prospective Study to Evaluate Long-term Clinical Outcomes of the GTS Cementless Femoral Stem
|
N/A | |
Completed |
NCT01700933 -
Dose-response: Exercise Therapy on Hip Osteoarthritis
|
N/A | |
Completed |
NCT01618708 -
A Study of the Safety and Effectiveness of Synvisc-One® (Hylan G-F 20) in Patients With Primary Osteoarthritis of the Hip
|
N/A | |
Completed |
NCT01214954 -
Early Rehabilitation After Total Hip Replacement
|
N/A | |
Active, not recruiting |
NCT00294424 -
Study on Costs and Effects of Waiting Time in Total Hip and Knee Replacements
|
N/A | |
Terminated |
NCT00588861 -
Total Hip Replacement With the Answer® Hip Stem and Ranawat/Burnstein® Shell Using Simplex® or Palacos® Bone Cement
|
N/A | |
Withdrawn |
NCT05054595 -
Audio-Recorded vs. Nurse-Led Brief Mindfulness-Based Intervention
|
N/A | |
Terminated |
NCT00973141 -
A Dose-ranging Study of the Safety and Effectiveness of JNJ-42160443 as add-on Treatment in Patients With Osteoarthritis-related Pain
|
Phase 2 | |
Recruiting |
NCT05014113 -
H-28 DELTA ST-C and Minima Retrospective Study.
|
||
Completed |
NCT01066936 -
Mini Stem DEXA (Dual Energy X-ray Absorptiometry)
|
||
Recruiting |
NCT05530551 -
Effect of Single vs Multiple Prophylactic Antibiotic Doses on PJI Following Primary THA in Patients With OA
|
N/A |