Osteoarthritis, Hip Clinical Trial
Official title:
Evaluation of Uncemented Echo Bi-Metric Full Proximal Profile THA Stem Versus Uncemented Bi-Metric Porous Primary THA Stem in a Randomized Controlled Trial Using RSA and DXA
| Verified date | February 2020 |
| Source | Rigshospitalet, Denmark |
| Contact | n/a |
| Is FDA regulated | No |
| Health authority | |
| Study type | Interventional |
The purpose of this study is to measure quantitatively the implant stability and implant related remodeling of the periprosthetic femoral bone of the new uncemented Echo® Bi-Metric® Full proximal Profile total hip arthroplasty (THA) stem, and compare it to the classical uncemented Bi-Metric® Porous Primary THA stem by measuring migration of the stem assessed by model-based radiosteriometric analysis (MB-RSA) and measuring the periprosthetic adaptive bone remodeling assessed by dual-energy x-ray absorptiometry (DXA).
| Status | Active, not recruiting |
| Enrollment | 62 |
| Est. completion date | December 2022 |
| Est. primary completion date | July 2019 |
| Accepts healthy volunteers | No |
| Gender | All |
| Age group | 30 Years to 75 Years |
| Eligibility |
Inclusion Criteria: - Patients bound to undergo total hip arthroplasty at the Department of Orthopedic - Surgery, Gentofte Hospital, Denmark. - Patients who have consented in writing to participate after having understood what it entails. - Patients diagnosed with primary osteoarthritis of one or both hips. Exclusion Criteria: - Infection including osteomyelitis and sepsis. - Exclusion as a result of technical shortcomings such as poor image quality, estimated by the investigator. - Diseases affecting the bone metabolism (osteoporosis, Pagets disease, hyperparathyreoidism etc.). - Uncooperative patient or patients with neurological disorders who are considered incapable of following directions. - Patients with alcohol or drug abuse, estimated by the investigators. - Patients considered unable to understand the information in patients-papers, or who do not want to participate in the study. - Patients who do not speak nor understand Danish. - Pregnancy |
| Country | Name | City | State |
|---|---|---|---|
| Denmark | Gentofte Hospital | Hellerup |
| Lead Sponsor | Collaborator |
|---|---|
| Rigshospitalet, Denmark | University Hospital, Gentofte, Copenhagen, Zimmer Biomet |
Denmark,
Haugan K, Husby OS, Klaksvik J, Foss OA. The migration pattern of the Charnley femoral stem: a five-year follow-up RSA study in a well-functioning patient group. J Orthop Traumatol. 2012 Sep;13(3):137-43. doi: 10.1007/s10195-012-0187-x. Epub 2012 May 11. — View Citation
Jiang Y, Jia T, Wooley PH, Yang SY. Current research in the pathogenesis of aseptic implant loosening associated with particulate wear debris. Acta Orthop Belg. 2013 Feb;79(1):1-9. Review. — View Citation
Nelissen RG, Pijls BG, Kärrholm J, Malchau H, Nieuwenhuijse MJ, Valstar ER. RSA and registries: the quest for phased introduction of new implants. J Bone Joint Surg Am. 2011 Dec 21;93 Suppl 3:62-5. doi: 10.2106/JBJS.K.00907. — View Citation
Nieuwenhuijse MJ, Valstar ER, Kaptein BL, Nelissen RG. Good diagnostic performance of early migration as a predictor of late aseptic loosening of acetabular cups: results from ten years of follow-up with Roentgen stereophotogrammetric analysis (RSA). J Bone Joint Surg Am. 2012 May 16;94(10):874-80. doi: 10.2106/JBJS.K.00305. — View Citation
O'Neill SC, Queally JM, Devitt BM, Doran PP, O'Byrne JM. The role of osteoblasts in peri-prosthetic osteolysis. Bone Joint J. 2013 Aug;95-B(8):1022-6. doi: 10.1302/0301-620X.95B8.31229. Review. — View Citation
Ryd L. Micromotion in knee arthroplasty. A roentgen stereophotogrammetric analysis of tibial component fixation. Acta Orthop Scand Suppl. 1986;220:1-80. — View Citation
Selvik G. Roentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal system. Acta Orthop Scand Suppl. 1989;232:1-51. Review. — View Citation
Snorrason F, Kärrholm J. Primary migration of fully-threaded acetabular prostheses. A roentgen stereophotogrammetric analysis. J Bone Joint Surg Br. 1990 Jul;72(4):647-52. — View Citation
Stiehl JB. Early cup instability with RSA predicts long-term aseptic loosening: commentary on an article by Marc J. Nieuwenhuijse, BSc, MD, et al.: "Good diagnostic performance of early migration as a predictor of late aseptic loosening of acetabular cups. Results from ten years of follow-up with Roentgen stereophotogrammetric analysis (RSA)". J Bone Joint Surg Am. 2012 May 16;94(10):e70. doi: 10.2106/JBJS.L.00080. — View Citation
| Type | Measure | Description | Time frame | Safety issue |
|---|---|---|---|---|
| Primary | Migration of the stem | The differences between the two stem designs are evaluated by measurements of migration of the stem assesed by Radiosteriometric analysis (RSA) | 2 years | |
| Secondary | Adaptive bone remodeling | The differences of the two stems are evaluated by measurements of the adaptive bone remodeling of the periprostetic area (femur) assesed by dual energy X-ray absorptiometry (DXA) | 2 years | |
| Secondary | Hip function | Hip function postoperatively assesed by Harris Hip Score and Oxford Hip Score | 2 years |
| Status | Clinical Trial | Phase | |
|---|---|---|---|
| Active, not recruiting |
NCT05773261 -
Clinical Investigation Comparing Two Different Ultra-porous Coated Surfaces of Uncemented Cups
|
N/A | |
| Recruiting |
NCT05223777 -
KINCISE™ Surgical Automated System in Total Hip Arthroplasty (THA)
|
N/A | |
| Recruiting |
NCT04731077 -
Avenir Complete Post-Market Clinical Follow-Up Study
|
N/A | |
| Not yet recruiting |
NCT04448106 -
Autologous Adipose Tissue-Derived Mesenchymal Stem Cells (AdMSCs) for Osteoarthritis
|
Phase 2 | |
| Completed |
NCT05070871 -
A Clinical Trial Investigating the Effect of Salmon Bone Meal on Osteoarthritis Among Men and Women
|
N/A | |
| Not yet recruiting |
NCT06162195 -
The ACTIVE Trial: A Prospective Randomised Control Trial Of The H1 Implant Versus Total Hip Replacement
|
N/A | |
| Withdrawn |
NCT02743208 -
Evaluation of a Short Femoral Stem in Total Hip Arthroplasty
|
N/A | |
| Completed |
NCT02944448 -
A Study Evaluating Pain Relief and Safety of Orally Administered CR845 in Patients With Osteoarthritis of Hip or Knee
|
Phase 2 | |
| Active, not recruiting |
NCT02229279 -
Evaluation of Teleconsulting on Rehabilitation After Hip and Knee Surgical Procedures
|
N/A | |
| Active, not recruiting |
NCT02851992 -
A Prospective Study to Evaluate Long-term Clinical Outcomes of the GTS Cementless Femoral Stem
|
N/A | |
| Completed |
NCT01618708 -
A Study of the Safety and Effectiveness of Synvisc-One® (Hylan G-F 20) in Patients With Primary Osteoarthritis of the Hip
|
N/A | |
| Completed |
NCT01700933 -
Dose-response: Exercise Therapy on Hip Osteoarthritis
|
N/A | |
| Completed |
NCT01214954 -
Early Rehabilitation After Total Hip Replacement
|
N/A | |
| Active, not recruiting |
NCT00294424 -
Study on Costs and Effects of Waiting Time in Total Hip and Knee Replacements
|
N/A | |
| Terminated |
NCT00588861 -
Total Hip Replacement With the Answer® Hip Stem and Ranawat/Burnstein® Shell Using Simplex® or Palacos® Bone Cement
|
N/A | |
| Withdrawn |
NCT05054595 -
Audio-Recorded vs. Nurse-Led Brief Mindfulness-Based Intervention
|
N/A | |
| Terminated |
NCT00973141 -
A Dose-ranging Study of the Safety and Effectiveness of JNJ-42160443 as add-on Treatment in Patients With Osteoarthritis-related Pain
|
Phase 2 | |
| Recruiting |
NCT05014113 -
H-28 DELTA ST-C and Minima Retrospective Study.
|
||
| Completed |
NCT01066936 -
Mini Stem DEXA (Dual Energy X-ray Absorptiometry)
|
||
| Recruiting |
NCT05530551 -
Effect of Single vs Multiple Prophylactic Antibiotic Doses on PJI Following Primary THA in Patients With OA
|
N/A |