Clinical Trials Logo

Clinical Trial Summary

This study aims to demonstrate that a polymer retractor functions the same as a standard metal retractor used during endoscopy and throat surgery. The retractor is the device that holds the mouth open so the surgeon can easily access the mouth and throat. For example, this study aims to confirm that the mouth is held open the same amount with a polymer retractor as it is with a metal retractor. Benchtop experiments have demonstrated that the metal and polymer retractor's function the same, and thus this study will use this in patients.


Clinical Trial Description

This study will include four stages of data collection: 1) Subject history, 2) intraoperative surgical working volume (SWV) assessment with stereoendoscopy and standard-of-care metal retractor, 3) intraoperative surgical working volume assessment with stereoendoscopy and 3D-printed polymer retractor, 4) intraoperative surgical working volume assessment with CT-imaging and 3D-printed polymer retractor. The investigators will conduct a comparative study examining differences in surgical exposure within the same patient when retraction is enabled through use of standard-of-care metal retractor vs. our 3D printed retractor. Patients to be recruited for the study will include those who present to the Head and Neck Tumor Clinic at Dartmouth-Hitchcock Medical Center (DHMC) with suspicious lesions identified in the oropharynx, hypopharynx or larynx. Currently the clinic sees about 20 patients per month that are scheduled for staging endoscopy in the operating room. Consent will be obtained from all participating subjects prior to participation. All surgeries will be performed at the Center for Surgical Innovation. Prior to surgery a standard-of-care Feyh-Kastenbauer (FK) or Crowe-Davis (CD) metal retractor will be positioned in the mouth of the patient and stabilized in suspension. A standard-of-care stereo vision endoscope will capture images of the oral cavity so that a 3D volume of the surgical working volume (SWV) can be measured. The time to place the retractor and surgical working volume metrics based on stereovision derived oral-cavity volumes and inter-incisive distance (IID) will be recorded. The FK and/or CD retractor will then be removed and replaced with our custom 3d-printed radiolucent retractor. The time to place this retractor and surgical working volume metrics based on stereovision derived oral-cavity volumes and inter-incisive distance will be recorded. A single CT scan with IV contrast will be obtained with the retractor in place and suspended. The standard surgical procedure will commence following routine methods. Following surgery, a second set of surgical working volume metrics based on stereovision derived oral-cavity volumes and inter-incisive distance will be recorded. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT06381505
Study type Observational
Source Dartmouth-Hitchcock Medical Center
Contact Ryan J Halter, PhD
Phone 603 646-0773
Email Ryan.J.Halter@dartmouth.edu
Status Not yet recruiting
Phase
Start date May 15, 2024
Completion date December 31, 2025

See also
  Status Clinical Trial Phase
Completed NCT05912335 - Clinical Efficiency of Xanthan Hydrogels Containing Local Anesthetics Encapsulated in Nanostructured Lipid Carries Phase 1
Completed NCT03855397 - Pain and Safety of Microneedles in Oral Cavity N/A
Recruiting NCT05911750 - Prevalence and Clinical Implications of HPV Infection in Male IBD Patients
Completed NCT05267938 - Microneedle Pretreatment as a Strategy to Improve the Effectiveness of Topical Anesthetics Formulations Phase 1