Clinical Trials Logo

Clinical Trial Details — Status: Recruiting

Administrative data

NCT number NCT05512455
Other study ID # 2022071901
Secondary ID
Status Recruiting
Phase
First received
Last updated
Start date April 1, 2022
Est. completion date August 20, 2022

Study information

Verified date August 2022
Source Fujian Medical University
Contact Lin HL
Phone 13599392799
Email linhonglei@foxmail.com
Is FDA regulated No
Health authority
Study type Observational

Clinical Trial Summary

the aim of this study was to evaluate the accuracy of the various virtual articulator mounting procedures.


Description:

The purpose of the present study was to evaluate the accuracy of various virtual articulator mounting procedures. For this purpose, 7 kinds of virtual mounting procedures were investigated:(1) indirect virtual mounting in MS VA by using an average facebow; (2) virtual mounting in MS VA by using average values; (3) virtual mounting in MS VA by using professional facial scanner; (4) virtual mounting in MS VA by using smartphone facial scanner; (5) virtual mounting in MS VA by using CBCT located in Bergstrom's point; (6) virtual mounting in MS VA by using CBCT located in the medial poles of the condyles; (7) virtual mounting in CA VA by using JMA,as the group to compare with the other mounting procedures. The null hypothesis is that no difference would be found in the static measurements taken virtually when comparing these 7 procedures for virtual mounting.


Recruitment information / eligibility

Status Recruiting
Enrollment 20
Est. completion date August 20, 2022
Est. primary completion date August 15, 2022
Accepts healthy volunteers Accepts Healthy Volunteers
Gender All
Age group 20 Years to 30 Years
Eligibility Inclusion Criteria: - 1.without any symptoms and signs of the temporomandibular joint 2.Willing to participate and to sign a written informed consent form 3.in good health and had no past history of any serious illness Exclusion Criteria: - emporomandibular or craniocervical disorders

Study Design


Related Conditions & MeSH terms


Locations

Country Name City State
China Fujian Medical University Fuzhou Fujian

Sponsors (1)

Lead Sponsor Collaborator
Fujian Medical University

Country where clinical trial is conducted

China, 

Outcome

Type Measure Description Time frame Safety issue
Primary the accuracy of different virtual articulator mounting procedures the virtual articulator mounting by using JMA is considered as the the gold standard, which can calculate the hinge axis of the temporomandibular joint, compare the hinge axis of the temporomandibular joint of different virtual articulator mounting procedures. immediately
See also
  Status Clinical Trial Phase
Completed NCT05371418 - Comparative Clinical and Radiographical Evaluation of Treatment of Angular Bone Defect Related to Over Erupted Tooth Using GTR Followed by Orthodontic Intrusion Versus Orthodontic Intrusion Followed by GTR N/A
Not yet recruiting NCT05440084 - Impact of CTO PCI (Chronic Total Occlusion Percutaneous Intervention) on Regular Physical Activity
Completed NCT06343454 - The Effect of Different Head Positions on Occlusal Contacts During Digital Interocclusal Bite Registration N/A
Recruiting NCT05507164 - Characterization of the Temporo-masseteric Nerve Block (TMNB) in Healthy Subjects Phase 2
Completed NCT05051878 - Effect of T-scan Occlusal Analysis and Adjustment vs Articulating N/A
Recruiting NCT06365528 - Tunneled Peripherally Inserted Central Catheter (PICC) in Adult Patients and Associated Outcomes N/A
Completed NCT05948254 - Utilized Scan Body Technique For Triple Function N/A
Not yet recruiting NCT06052501 - 3D Evaluation of the Lip Support in a Full-arch Implant-supported Rehabilitations
Completed NCT03332264 - Sequent Please Drug Coated Balloons Versus Primary Stent Application in Long SFA Lesions N/A
Recruiting NCT05780619 - Diagnostic Performance of the Resistance Index (RI) for the Assessment of Cerebral Vasoreactivity in Transcranial Doppler
Completed NCT01131754 - Heparin 100U/L for Prevention of PVC Complications Phase 3
Terminated NCT03248739 - Comparison of EVD Catheter Diameter on Occlusion and Replacement N/A
Completed NCT04701970 - Effect of Mandibular Complete Dentures Relining on Occlusal Force Distribution N/A
Not yet recruiting NCT03114722 - Citrate 4% Versus Heparinised Saline in Preventing Peripherally Inserted Central Catheter (PICC) Occlusions Phase 2
Completed NCT05637372 - Relationships Between Anterior and Condylar Guidance - Comparison by CBCT and Electronic Axiography
Not yet recruiting NCT06402045 - Assessment of the Occlusal Characteristics and Orthodontic Treatment Needs for Egyptian Children( 6-12)years Old
Completed NCT01570114 - Covered Metallic Stent and Benign Colonic Strictures Phase 2
Completed NCT04798729 - Comparison of Two Different Digital Methods in Occlusal Analysis
Completed NCT05949151 - Occlusal Forces and Muscle Activity in Fixed Versus Removable Mandibular Implant Supported Overdenture N/A
Completed NCT05490797 - Effects of Mobile Application Dexteria Fine Motor Skills on Hand Dexterity and Grip Strength in Chronic Stroke Patients N/A