Clinical Trial Summary

evaluation of occlusal force distribution was carried out with the aid of T-Scan device (Tekscan Inc., South Boston, MA, USA) for mandibular complete dentures before and after relining with long term soft liner for controlled type 2 diabetic patients.


Clinical Trial Description

A crossover clinical study was carried out with previously constructed and used conventional complete dentures before relining with soft denture liners and then with the same dentures after relining with soft denture liners. The study sample included 50 males completely edentulous contributors, All patients were controlled type 2 diabetes during the study period. All selected patients had previously constructed and used conventional heat cured acrylic resin complete dentures for not less than two years with history of retention and stability problems of mandibular dentures. Mandibular complete dentures had received the essential prosthetic adjustments aiming to achieve optimal retention, maximum stability and the necessary occlusal contacts. The first occlusal parameters were recorded before denture relining. Relining of mandibular dentures was performed and Patients were comfortably using their relined mandibular complete dentures for at least three months and the retention and stability of the conventional dentures were assessed before second recording of occlusal parameter. The evaluation of occlusal force distribution was carried out with the aid of T-Scan device (Tekscan Inc., South Boston, MA, USA). The first record was recorded before denture relining and the second record was three months after denture relining ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04701970
Study type Interventional
Source National Research Centre, Egypt
Contact
Status Completed
Phase N/A
Start date June 1, 2020
Completion date November 12, 2020

See also
  Status Clinical Trial Phase
Completed NCT05371418 - Comparative Clinical and Radiographical Evaluation of Treatment of Angular Bone Defect Related to Over Erupted Tooth Using GTR Followed by Orthodontic Intrusion Versus Orthodontic Intrusion Followed by GTR N/A
Not yet recruiting NCT05440084 - Impact of CTO PCI (Chronic Total Occlusion Percutaneous Intervention) on Regular Physical Activity
Completed NCT06343454 - The Effect of Different Head Positions on Occlusal Contacts During Digital Interocclusal Bite Registration N/A
Recruiting NCT05507164 - Characterization of the Temporo-masseteric Nerve Block (TMNB) in Healthy Subjects Phase 2
Completed NCT05051878 - Effect of T-scan Occlusal Analysis and Adjustment vs Articulating N/A
Not yet recruiting NCT06365528 - Tunneled Peripherally Inserted Central Catheter (PICC) in Adult Patients and Associated Outcomes N/A
Completed NCT05948254 - Utilized Scan Body Technique For Triple Function N/A
Not yet recruiting NCT06052501 - 3D Evaluation of the Lip Support in a Full-arch Implant-supported Rehabilitations
Completed NCT03332264 - Sequent Please Drug Coated Balloons Versus Primary Stent Application in Long SFA Lesions N/A
Recruiting NCT05780619 - Diagnostic Performance of the Resistance Index (RI) for the Assessment of Cerebral Vasoreactivity in Transcranial Doppler
Completed NCT01131754 - Heparin 100U/L for Prevention of PVC Complications Phase 3
Terminated NCT03248739 - Comparison of EVD Catheter Diameter on Occlusion and Replacement N/A
Not yet recruiting NCT03114722 - Citrate 4% Versus Heparinised Saline in Preventing Peripherally Inserted Central Catheter (PICC) Occlusions Phase 2
Completed NCT05637372 - Relationships Between Anterior and Condylar Guidance - Comparison by CBCT and Electronic Axiography
Completed NCT01570114 - Covered Metallic Stent and Benign Colonic Strictures Phase 2
Completed NCT04798729 - Comparison of Two Different Digital Methods in Occlusal Analysis
Completed NCT05949151 - Occlusal Forces and Muscle Activity in Fixed Versus Removable Mandibular Implant Supported Overdenture N/A
Completed NCT05490797 - Effects of Mobile Application Dexteria Fine Motor Skills on Hand Dexterity and Grip Strength in Chronic Stroke Patients N/A
Not yet recruiting NCT04940702 - Effectiveness of Focal Vibration and Blood Flow Restriction Within a Multicomponent Exercise Programme. N/A
Recruiting NCT03149913 - Local Paclitaxel or Balloon Angioplasty Below the Knee N/A