Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT06211803
Other study ID # KB16/2022
Secondary ID TEAM POIR.04.04.
Status Completed
Phase
First received
Last updated
Start date March 11, 2022
Est. completion date March 22, 2022

Study information

Verified date January 2024
Source Jagiellonian University
Contact n/a
Is FDA regulated No
Health authority
Study type Observational [Patient Registry]

Clinical Trial Summary

Positron emission tomography (PET) is a diagnostic imaging technique that uses positron emission (e-) to image changes in diagnosed tissues. Detector systems are an important part of PET scanners. They can convert gamma photons into fluorescent photons to obtain information about energy, time and position, of the gamma photons obtained through the use of an appropriate positron-emitting radiopharmaceutical. Conventional PET scanners are expensive mostly because they require the use of LSO (lutetium oxyorthosilicate) or LYSO (lutetium yttrium oxyorthosilicate) scintillation crystals. Such crystal scintillators are very costly and difficult to obtain, which limits accessibility of the PET- scanners. The prototype J-PET scanner tested in this trial uses plastic scintillators in which different physical phenomena occur compared to crystal scintillators. In addition, the J-PET scanner prototype is equipped with unique software enabling three-photon imaging, based on the annihilation resulting from the formation of the orto-positronium (o-Ps) in diagnosed tissue. The aim of this study is to demonstrate the clinical acceptability of such scanners based on plastic scintillators, which can additionally collect and process information on the lifetime of o-Ps derived from routinely used radiopharmaceuticals. Additionally, the aim of this study is to demonstrate the use of the new diagnostic indicator "positronium biomarker" in a prospective study, compared to routine diagnostic scanning.


Description:

The J-PET scanner is the world's first positron tomograph based on plastic strip scintillators to measure the lifetime of the ortho-positronium (o-Ps) atom. This is a modular scanner, designed and installed at the Department of Experimental Particle Physics and Applications of the Jagiellonian University in Krakow. The J-PET scanner is based on technology patented in 2014 and 2016. The J-PET scanner, unlike PET scanners commonly used in diagnostics, has three important features: 1. J-PET scintillators are made of plastic instead of expensive-to-produce LSO (lutetium oxyorthosilicate) or LYSO (lutetium yttrium oxyorthosilicate) scintillation crystals use in regular PET scanners; 2. J-PET is modular and can be adapted to the patient's size and expanded to a total-body PET scanner because; 3. J-PET can be used to test an additional parameter called the "positronium biomarker" which has not been used so far. Ad. 1. Conventional PET scanners use LSO or LYSO scintillation crystals, which exploit the photoelectric effect and convert gamma photons into fluorescent photons to obtain information on the energy, time and position of gamma photons emitted by the positron annihilation (e+) process obtained by using an appropriate e+ emitting radiopharmaceutical. In plastic scintillators used in J-PET, the Compton effect is used, i.e. the phenomenon of scattering of high-energy photons on free or weakly bound electrons of the scintillator. Ad. 2. The modular J-PET scanner can also be easily integrated with existing computed tomography (CT) systems, allowing for simultaneous conduction of both types of examinations. Ad. 3. Positronium imaging is applied in the J-PET scanner. The PET technique uses radioisotopes that emit positron radiation (beta+). Traditional PET scanners image the distribution of gamma ray photons produced by the annihilation of an electron (e-) and a positron (e+). Annihilation may be preceded by the appearance of a positron atom - a quasi-stable system composed of an electron (e-) and its antiparticle - positron (e+), which occurs in approximately 30-40% of all annihilations occurring in the patient's body. The time of such annihilation taking place through the state of the positronium atom depends on whether a positronium will be created in which e- and e+ will have parallel spins (triplet state ↑↑, this system is called ortho-positronium - o-Ps) or antiparallel spins (state singlet ↑ ↓, this system is called para-positronium - p-Ps). The average life time of o-Ps in vacuum is more then 1000 times longer (142 nano-seconds [ns]), then the average life time of p-Ps (125 pico-seconds [ps]). The average lifetime of o-Ps in a vacuum is over 1000 times longer (142 nanoseconds [ns]) than the average lifetime of p-Ps (125 picoseconds [ps]). The second difference is that o-Ps annihilation takes place over 3 photons, which has not been detected so far and which traditional PET. the annihilation time of the o-Ps atom can be an additional diagnostic parameter ("positronium biomarker") to be measured and analyzed in the J-PET scanner. The clinical application of such "positronium biomarker" in terms of lesion detection, image quality and quantification is yet to be determined, which this study aims to address.


Recruitment information / eligibility

Status Completed
Enrollment 10
Est. completion date March 22, 2022
Est. primary completion date March 22, 2022
Accepts healthy volunteers No
Gender All
Age group 18 Years to 80 Years
Eligibility Inclusion Criteria: The patient is referred for a PET/CT scan, in accordance with recognized indications for examining the brain or the entire body. - Age over 18 years - Informed, voluntary consent to participate in the study Exclusion Criteria: - Pregnant women, breastfeeding women - People with a previously diagnosed allergy to radiopharmaceuticals - age under 18 years - Lack of cooperation with the patient

Study Design


Intervention

Diagnostic Test:
Positron-Emission Tomography Imaging
Examination of radiation distribution in the patient brain and body after completing a routine examination on a PET diagnostic device. J-PET prototype tests will be carried out in patients who have undergone a classic PET examination after administration of [18F]FDG), [68Ga]Ga-PSMA or [68Ga]Ga-DOTATATE). The duration of the additional exam will be approximately 20 minutes.

Locations

Country Name City State
Poland Department of Nuclear Medicine Warsaw Mazowieckie

Sponsors (2)

Lead Sponsor Collaborator
Jagiellonian University Medical University of Warsaw

Country where clinical trial is conducted

Poland, 

References & Publications (5)

Dadgar M, Parzych S, Baran J, Chug N, Curceanu C, Czerwinski E, Dulski K, Elyan K, Gajos A, Hiesmayr BC, Kaplon L, Klimaszewski K, Konieczka P, Korcyl G, Kozik T, Krzemien W, Kumar D, Niedzwiecki S, Panek D, Perez Del Rio E, Raczynski L, Sharma S, Shivani S, Shopa RY, Skurzok M, Stepien EL, Tayefi Ardebili F, Tayefi Ardebili K, Vandenberghe S, Wislicki W, Moskal P. Comparative studies of the sensitivities of sparse and full geometries of Total-Body PET scanners built from crystals and plastic scintillators. EJNMMI Phys. 2023 Oct 11;10(1):62. doi: 10.1186/s40658-023-00572-5. — View Citation

Moskal P, Dulski K, Chug N, Curceanu C, Czerwinski E, Dadgar M, Gajewski J, Gajos A, Grudzien G, Hiesmayr BC, Kacprzak K, Kaplon L, Karimi H, Klimaszewski K, Korcyl G, Kowalski P, Kozik T, Krawczyk N, Krzemien W, Kubicz E, Malczak P, Niedzwiecki S, Pawlik-Niedzwiecka M, Pedziwiatr M, Raczynski L, Raj J, Rucinski A, Sharma S, Shivani, Shopa RY, Silarski M, Skurzok M, Stepien EL, Szczepanek M, Tayefi F, Wislicki W. Positronium imaging with the novel multiphoton PET scanner. Sci Adv. 2021 Oct 15;7(42):eabh4394. doi: 10.1126/sciadv.abh4394. Epub 2021 Oct 13. — View Citation

Moskal P, Kisielewska D, Curceanu C, Czerwinski E, Dulski K, Gajos A, Gorgol M, Hiesmayr B, Jasinska B, Kacprzak K, Kaplon L, Korcyl G, Kowalski P, Krzemien W, Kozik T, Kubicz E, Mohammed M, Niedzwiecki S, Palka M, Pawlik-Niedzwiecka M, Raczynski L, Raj J, Sharma S, Shivani, Shopa RY, Silarski M, Skurzok M, Stepien E, Wislicki W, Zgardzinska B. Feasibility study of the positronium imaging with the J-PET tomograph. Phys Med Biol. 2019 Mar 7;64(5):055017. doi: 10.1088/1361-6560/aafe20. — View Citation

Moskal P, Kubicz E, Grudzien G, Czerwinski E, Dulski K, Leszczynski B, Niedzwiecki S, Stepien EL. Developing a novel positronium biomarker for cardiac myxoma imaging. EJNMMI Phys. 2023 Mar 24;10(1):22. doi: 10.1186/s40658-023-00543-w. — View Citation

Moskal P, Stepien EL. Prospects and Clinical Perspectives of Total-Body PET Imaging Using Plastic Scintillators. PET Clin. 2020 Oct;15(4):439-452. doi: 10.1016/j.cpet.2020.06.009. Epub 2020 Jul 29. — View Citation

Outcome

Type Measure Description Time frame Safety issue
Primary Assessment of the quality of tests performed using J-PET prototype The reference result for the J-PET test will be the result obtained using a PET/CT device owned by the Department of Nuclear Medicine of the Medical University of Warsaw. For this purpose, the test images obtained with the two cameras will be analyzed by a team of medical physicists (phantom tests) and doctors, according to the principles given above. Initial analyzes will last 12 weeks
Secondary Analysis of positronium duration in the disease focus and reference area The lifetime of positronium is a parameter characterizing the examined structures, including the structures of brain tissues. The J-PET group proposed the use of positronium lifetime as a new diagnostic biomarker. There are currently no similar studies in the literature. It is planned that the first results will be obtained after 6 months.
See also
  Status Clinical Trial Phase
Completed NCT01218555 - Study of Everolimus (RAD001) in Combination With Lenalidomide Phase 1
Recruiting NCT03412877 - Administration of Autologous T-Cells Genetically Engineered to Express T-Cell Receptors Reactive Against Neoantigens in People With Metastatic Cancer Phase 2
Withdrawn NCT04614766 - A Clinical Trial Evaluating the Safety of Combining Lutathera(R) and Azedra(R) to Treat Mid-gut Neuroendocrine Tumors Phase 1/Phase 2
Recruiting NCT05556473 - F-Tryptophan PET/CT in Human Cancers Phase 1
Completed NCT03273712 - Dosimetry-Guided, Peptide Receptor Radiotherapy (PRRT) With 90Y-DOTA- tyr3-Octreotide (90Y-DOTATOC) Phase 2
Recruiting NCT05636618 - Targeted Alpha-Particle Therapy for Advanced SSTR2 Positive Neuroendocrine Tumors Phase 1/Phase 2
Terminated NCT03986593 - Cryoablation of Bone Metastases From Endocrine Tumors N/A
Recruiting NCT04584008 - Targeted Agent Evaluation in Digestive Cancers in China Based on Molecular Characteristics N/A
Completed NCT02815969 - The Indol Profile; Exploring the Metabolic Profile of Neuroendocrine Tumors
Completed NCT02441062 - Impact of Ga-68 DOTATOC PET-CT Imaging in Management of Neuroendocrine Tumors Phase 2
Active, not recruiting NCT02174549 - Dose-defining Study of Tirapazamine Combined With Embolization in Liver Cancer Phase 1/Phase 2
Completed NCT02132468 - A Ph 2 Study of Fosbretabulin in Subjects w Pancreatic or Gastrointestinal Neuroendocrine Tumors w Elevated Biomarkers Phase 2
Completed NCT02134639 - PET-CT Imaging of Neuro-endocrine Tumors and Preliminary Clinical Evaluation N/A
Recruiting NCT01201096 - Neo-adjuvant Peptide Receptor Mediated Radiotherapy With 177Lutetium in Front of Curative Intended Liver Transplantation in Patients With Hepatic Metastasis of Neuroendocrine Tumors (NEO-LEBE) N/A
Terminated NCT01163526 - Perfusion CT as a Predictor of Treatment Response in Patients With Hepatic Malignancies N/A
Completed NCT01099228 - Combination Targeted Radiotherapy in Neuroendocrine Tumors N/A
Completed NCT00171873 - Antiproliferative Effect of Octreotide in Patients With Metastasized Neuroendocrine Tumors of the Midgut Phase 3
Active, not recruiting NCT05077384 - Open-label Study of Surufatinib in Japanese Patients Phase 1/Phase 2
Active, not recruiting NCT04544098 - Lutathera in People With Gastroenteropancreatic (GEP), Bronchial or Unknown Primary Neuroendocrine Tumors That Have Spread to the Liver Early Phase 1
Active, not recruiting NCT02736500 - Peptide Receptor Radionuclide Therapy With 177Lu-Dotatate Associated With Metronomic Capecitabine In Patients Affected By Aggressive Gastro-Etero-Pancreatic Neuroendocrine Tumors Phase 1/Phase 2