Clinical Trials Logo

Clinical Trial Summary

The aim of this study is to collect synchronized data from multiple monitoring techniques of mechanical ventilation (pressure/flow waves from the ventilator, electrical impedance tomography - EIT, esophageal pressure, capnography) in patients ventilated either on intensive care units or during anesthesia and evaluate the data by detailed mathematical analysis, to test three hypotheses: 1. Various published methods of calculation of the expiratory time constant provide different results in most cases. 2. Inhomogeneous ventilation (as described by EIT) affects the form of the expiratory flow curve and thus the calculated expiratory time constants. 3. The calculation of mechanical energy transferred to the lungs is affected by the chosen technique and length of the inspiratory pause maneuver. This study does not test any new or non-standard methods and does not in any way interfere with the course of treatment indicated by the clinician, apart from extending the monitoring techniques.


Clinical Trial Description

Mechanical ventilation is known to cause various complications, generally known as ventilator induced lung injury. Thus, detailed monitoring is essential. However, data interpretation is complicated in clinical practice. The investigators aim to collect synchronized data from multiple monitoring techniques of mechanical ventilation (pressure/flow waves from the ventilator, electrical impedance tomography - EIT, esophageal pressure, capnography) in patients ventilated either on intensive care units or during anesthesia and evaluate the data by detailed mathematical analysis. The results will be used to explore the complexity of seemingly simple and often used calculations describing the course of mechanical ventilation - mostly the expiratory time constant and amount of mechanical energy transferred to the lungs. The investigators primarily aim to test three hypotheses: 1. Various published methods of calculation of the expiratory time constant provide different results in most cases. 2. Inhomogeneous ventilation (as described by EIT) affects the form of the expiratory flow curve and thus the calculated expiratory time constants. 3. The calculation of mechanical energy transferred to the lungs is affected by the chosen technique and length of the inspiratory pause maneuver. For this, the investigators plan to recruit 50 patients undergoing general anesthesia with controlled mechanical ventilation and 50 patients hospitalized on intensive care units. Monitoring of those patients will be protocolized and will in all cases include pressure/flow monitoring of the mechanical ventilator, capnography, and electrical impedance tomography. Esophageal pressure monitoring will be introduced where indicated by the clinician or where nasogastric tube insertion will be indicated (as the pressure can be measured by a combined catheter). This study thus does not test any new or non-standard methods and does not in any way interfere with the course of treatment indicated by the clinician, apart from extending the monitoring techniques. Patient data will be anonymized and all the enrolled patients or their families will sign an informed consent as agreed by the ethical committee of our hospital. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT06236685
Study type Interventional
Source Czech Technical University in Prague
Contact
Status Enrolling by invitation
Phase N/A
Start date March 2024
Completion date December 2027

See also
  Status Clinical Trial Phase
Recruiting NCT05030337 - Optimising Ventilation in Preterms With Closed-loop Oxygen Control N/A
Completed NCT05144607 - Impact of Inspiratory Muscle Pressure Curves on the Ability of Professionals to Identify Patient-ventilator Asynchronies N/A
Recruiting NCT03697785 - Weaning Algorithm for Mechanical VEntilation N/A
Completed NCT05084976 - Parental Perception of COVID-19 Vaccine in Technology Dependent Patients
Active, not recruiting NCT05886387 - a Bayesian Analysis of Three Randomised Clinical Trials of Intraoperative Ventilation
Completed NCT04429399 - Lowering PEEP: Weaning From High PEEP Setting N/A
Completed NCT02249039 - Intravenous Clonidine for Sedation in Infants and Children Who Are Mechanically Ventilated - Dosing Finding Study Phase 1
Recruiting NCT02071524 - Evaluation of the Effects of Fluid Therapy on Respiratory Mechanics N/A
Completed NCT01114022 - Prevention Inhalation of Bacterial by Using Endotracheal Tube Balloon Polyvinyl Chloride or Polyurethane N/A
Completed NCT00893763 - Strategies To Prevent Pneumonia 2 (SToPP2) Phase 2
Terminated NCT05056103 - Automated Secretion Removal in ICU Patients N/A
Active, not recruiting NCT04558476 - Efficacy of CONvalescent Plasma in Patients With COVID-19 Treated With Mechanical Ventilation Phase 2
Recruiting NCT05295186 - PAV Trial During SBT Trial
Active, not recruiting NCT05370248 - The Effect of 6 ml/kg vs 10 ml/kg Tidal Volume on Diaphragm Dysfunction in Critically Mechanically Ventilated Patient N/A
Completed NCT04589910 - Measuring Thickness of the Normal Diaphragm in Children Via Ultrasound. N/A
Completed NCT04818164 - Prone Position Improves End-Expiratory Lung Volumes in COVID-19 Acute Respiratory Distress Syndrome
Completed NCT04193254 - LPP , MP and DP:Relation With Mortality and SOFA in Mechanically Ventilated Patients in ER, Ward and ICU
Not yet recruiting NCT03259854 - Non Invasive Mechanical Ventilation VERSUS Oxygen MASK N/A
Not yet recruiting NCT03245684 - Assisted or Controlled Ventilation in Ards (Ascovent) N/A
Completed NCT06332768 - NIV Versus HFO Versus Standard Therapy Immediately After Weaning From Mechanical Ventilation in ARDS Patients N/A