Clinical Trials Logo

Clinical Trial Summary

The goal of this observational validation study is to determine the best implementation of fluoroscopic and CT ventilation imaging in patients having non-stereotactic ablative body radiotherapy (non-SABR) radiotherapy for stages II-IV lung cancer. The main questions it aims to answer are: - Assess the dosimetric variation in functional avoidance radiation therapy (RT) plans produced using these ventilation imaging techniques, - Establish a quality assurance procedure for functional lung avoidance radiation therapy, and - Evaluate the clinical acceptable thresholds for accuracy of the method. Participants will: Prior to radiation therapy treatment, patients will undergo: 1. A standard of care 4DCT scan for radiation therapy simulation, 2. Pulmonary Function Tests (PFT) 3. A 4D attenuation correction CT 4. Breath Hold Computed Tomography (BHCT) imaging where static end-inspiration and end-expiration BHCT scans will be acquired, 5. Nuclear medicine imaging where a Tc-99m MAA SPECT perfusion scan and a Galligas PET ventilation scan will be acquired, 6. Fluoroscopy where 1-breath cine-fluoroscope sequences will be acquired at five different angles across the chest, 7. A 4D Cone Beam Computed Tomography (4DCBCT) scan. 8. Scans in points 4 to 7 above will be repeated at the end of treatment. Individual participants provide their own internal control. Galligas PET ventilation images (control) are compared with ventilation images derived from additional scans (comparator) for each participant. Tc-99m MAA SPECT perfusion images (control) are compared with perfusion images derived from BHCT scans (comparator) for each patient. There will be no change to patient treatment and patients will be treated using a standard of care anatomical based treatment plan. The pre-treatment 4DCBCT scan is part of standard of care.


Clinical Trial Description

Lung cancer is the leading cause of cancer mortality worldwide with non-small cell lung cancers (NSCLC) accounting for approximately 85% of all lung cancers diagnosed. Surgery, immunotherapy, chemotherapy, targeted therapy, and radiation therapy may be used alone or in combination for lung cancer treatment depending on the cancer staging. Radiation therapy is a primary component of lung cancer treatment with 77% of lung cancer patients having evidence-based indication for external beam radiotherapy at some point through their treatment journey. Radiotherapy is associated with radiation-induced toxicities such as radiation pneumonitis and fibrosis that adversely impacts a patient's quality of life and limits the dose that can be safely delivered. Radiation pneumonitis is the inflammation of lung tissue with symptoms such shortness of breath, cough, and fever, manifesting 4 to 12 weeks following the completion of a radiotherapy course. Symptomatic pneumonitis, defined as grade 2 or higher, has an overall incidence of 29.8% with conventional radiotherapy. Current radiotherapy treatment planning assumes that lung function is homogeneous throughout the organ and does not account for regional differences in lung function. These regional differences may arise from the cancer growth itself via tumour compression of lung structures, or from pre-existing, often smoking-induced factors which can also impact the lung health of cancer patients. Pre-existing conditions that can impact lung health include chronic obstructive pulmonary disease (COPD), fibrosis and thickening of the lymphatics in the lung, emphysema, asbestosis and partial lung collapse or side effects from previous cancer treatment such as fluid in the lungs, inflammation and pneumonitis, or even partial lung removal. In order to give patients the best quality of life after radiotherapy, it is crucial to preserve as much healthy lung as possible during the course of treatment. Functional lung avoidance treatment planning for radiotherapy has the potential to reduce pulmonary toxicity by minimising irradiation of healthy lung tissue based on functional maps of the lung. Nuclear medicine functional lung images have been previously incorporated into radiotherapy treatment planning for the purposes of reducing mean doses to functional lung and hence radiation-induced toxicity. Normal tissue complication probability (NTCP) models have also predicted an overall reduction of 6% and 3% for grade 2+ and 3+ radiation pneumonitis, respectively, with functional planning while honouring dose constraints to the target and organs at risk. Nuclear medicine scans are expensive, time consuming and not available in all institutions. CT ventilation imaging has been developed as a cheaper and more accessible alternative to nuclear medicine for mapping the healthy areas of the lung as part of routine pre-treatment CT acquisition. The key steps in CT ventilation imaging are: 1. Acquire CT images of the lung at exhale and inhale states, using 4DCT or BHCT. 4DCT is a technology that forms the standard of care for lung cancer radiation therapy throughout the world. 4DCT acquires a set of 8 to 10 CT images from peak inhale to peak exhale showing the motion of the lungs as a patient breathes while BHCT acquires static end-inspiration and end-expiration images of the lung as the patient holds their breath for around 10 seconds. 2. Deformable image registration is used to determine a spatial mapping (deformation map) between the different CT images (from peak inhale to peak exhale). 3. Application of a ventilation metric to quantify high and low functioning lung which involves quantitative analysis based on the information from the deformable image registration. The resulting ventilation image is superimposed directly onto the anatomic image, providing an added dimension of functional information which is easy to understand and can be of direct benefit to radiotherapy treatment planning. There are existing commercial products, CT Lung Ventilation Analysis Software and XV Technology Lung Ventilation Analysis Software (4DMedical Limited, Melbourne), for producing ventilation maps from CT scans and fluoroscopy imaging sequences. Unlike CT which produces one or more 3D images, fluoroscopy produces a fast sequence of 2D X-ray images. These images are usually acquired by dedicated C-arm scanners in radiology departments or surgical theatres and has not previously been assessed with relation to radiotherapy. Cine-fluoroscope sequences capturing at least one complete, continuous breath are acquired at five distinct angles across the chest during spontaneous breathing and a lung motion field is reconstructed to produce a ventilation map. As Therapeutic Goods Administration (TGA)-approved modalities of lung ventilation assessment, comparison of these techniques offers valuable insights into their robustness. Functional lung avoidance treatment planning based on pre-treatment ventilation images can be compromised by interfraction (week-to-week) ventilation changes during treatment, such as those resulting from tumour regression. 4DCBCT allows convenient acquisition of anatomical images on the radiotherapy system to ensure accurate patient positioning prior to treatment delivery. Existing techniques developed for computed tomography ventilation imaging (CTVI) can be applied to 4DCBCT images to produce ventilation images that can be used to adapt treatment planning and minimise irradiation of healthy lung. However, 4DCBCT suffers from poor image quality and the physiological accuracy of 4DCBCT-based ventilation images remains to be assessed. Previous studies have validated the physiological accuracy of CT ventilation imaging against the existing clinical gold standard Galligas PET ventilation imaging. These studies found strong correlation at the lobar level (several cm) and moderate positive correlations at the regional level (2 to 5 mm). Clinical evidence for efficacy of the functional lung avoidance technique using CT ventilation images is beginning to be gathered. Vinogradskiy et al. performed a Phase II clinical trial, comparing radiation pneumonitis rates in a cohort treated with functional lung avoidance against historic controls. The authors found the rate of grade ≥2 radiation pneumonitis to be 14.9% of patients in the functional lung avoidance cohort, compared to an historical rate of 25%, reporting a positive trial outcome with a power of 80% and significance of 0.05. Using Xenon-enhanced CT ventilation, Huang et al performed a Phase II study comparing functional lung avoidance to historic controls. With a 17% rate of grade ≥2 radiation pneumonitis compared to the historical control of 30%, the authors also concluded a positive trial outcome with a power of 80% and significance of 0.05. Despite this encouraging clinical evidence, there are still gaps in knowledge on assessing the best technical implementation of CT ventilation imaging, quality assurance of the process and the clinically acceptable threshold of accuracy required. To this end, the focus of our proposed clinical trial is to determine the best implementation of fluoroscopic and CT ventilation imaging. To achieve this, we will assess the physiological accuracy of different CT and fluoroscopy-based ventilation imaging techniques, using Galligas as a ground truth for true ventilation. Secondary aims of our study are to assess the dosimetric variation in functional avoidance radiotherapy plans produced using these ventilation imaging techniques, establish a quality assurance procedure for functional lung avoidance RT and to evaluate the clinical acceptable thresholds for accuracy of the method. To compare the impact of functional lung avoidance planning on the radiation therapy treatment workflow, functional avoidance radiation therapy treatment plans will be created in addition to standard of care treatment plans and the difference in planning time quantified. The predicted reduction in radiation pneumonitis rates will be quantified using the method of Faught et al. and the predicted reduction in number of hospitalisations and medical costs will be calculated. CT perfusion imaging methods have been recently developed to allow the computation of perfusion information from non-contrast inhale/exhale CT image pairs. CTPI is based on the principle that there is a mass change within the lung during the respiratory cycle due to changes in blood volume. Perfusion is derived from this mass change which is calculated at the voxel resolution using intensity-based material density estimates and spatial mapping between different CT images. Computed tomography perfusion imaging (CTPI) is a nascent technology that requires further validation of its accuracy. However, there is currently a lack of paired BHCT-perfusion datasets for validation. To date, the only validation study conducted by Castillo et al. reported a median correlation of 0.57 between CTPI and SPECT perfusion imaging. The University of Sydney and Northern Sydney Local Health District have recently installed a new Total Body PET scanner at the Royal North Shore Hospital which can acquire scans in a single bed position with higher sensitivity, faster acquisition time, and longer scan length. The higher sensitivity of this new device allows faster imaging, including 4D (time series) images, giving more detailed ventilation information. To support this, an additional low-dose 4DCT scan, across the lungs only rather than the full scan length, will be acquired in pre-treatment imaging for the purpose of investigating 4D attenuation correction. Choice of comparators Control - Galligas PET ventilation images will be acquired for each participant and used as the ground truth. Galligas PET is an established modality for acquiring ventilation images with higher spatial resolution than SPECT imaging. - Tc-99m MAA SPECT images will be acquired for each participant and used as the ground truth for perfusion. 99mTc-MAA SPECT is an established modality for acquiring perfusion images. - 4D PET images reconstructed with 3D attenuation CT. - Standard of care anatomical based treatment plans will be generated for each participant. Comparators - Ventilation images derived from BHCT, fluoroscopy, 4DCBCT, and 4DCT scans acquired from each participant. X-ray-based ventilation imaging has been developed as a cost-effective and accessible alternative for visualising lung ventilation. - Perfusion images derived from BHCT scans acquired from each patient. CT perfusion imaging is under development as a cost-effective and accessible alternative for visualising lung perfusion. - 4D PET images reconstructed with 4D attenuation CT. 4D attenuation is proposed to give more accurate PET imaging in regions where breathing motion is expected. - Functional based radiotherapy plans created using the ventilation images, in terms of predicted radiation pneumonitis rates. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT06159660
Study type Observational
Source University of Sydney
Contact Clinical Trial Coordinator
Phone +61 2 8627 1185
Email Shona.Silvester@sydney.edu.au
Status Not yet recruiting
Phase
Start date March 1, 2024
Completion date September 1, 2026

See also
  Status Clinical Trial Phase
Recruiting NCT05078918 - Comprehensive Care Program for Their Return to Normal Life Among Lung Cancer Survivors N/A
Completed NCT04508270 - Significance of Early Mobilization After VATS-L
Active, not recruiting NCT03667716 - COM701 (an Inhibitor of PVRIG) in Subjects With Advanced Solid Tumors. Phase 1
Completed NCT05469425 - Home-based Preoperative Exercise Training for Lung Cancer Patients Undergoing Surgery N/A
Recruiting NCT05046067 - Feasibility Study of Anatomical Modeling for Image Guided Thoracic Surgery N/A
Terminated NCT03090880 - Prophylaxis of Venous Thromboembolism in Advanced Lung Cancer (PROVE) Phase 3
Recruiting NCT05596760 - Promoting Goals-of-Care Discussions for Patients With Memory Problems and Their Caregivers N/A
Completed NCT02498860 - Efficacy and Safety of Adjuvant Pemetrexed Plus Cisplatin for Adenocarcinoma of Lung Phase 2
Completed NCT02952261 - Application of 3D Printing Technique in Small Pulmonary Nodule Localization N/A
Not yet recruiting NCT06024538 - Role of Cancer-associated Fibroblast, MDSCs and Immune Cell Interplays in the Resistance of Non-small Cell Lung Cancer to Anti-PD1/PD-L1 Therapies
Recruiting NCT02965300 - The Value of VOCs Analysis in Exhaled Breath for Pulmonary Benign and Malignant Lesion Diagnosis N/A
Completed NCT02616211 - An Integrated Approach to Treating Recurrent Thoracic Carcinomas Resistant to Tyrosine Kinase Inhibitors
Recruiting NCT00765986 - Pilot Study of 18F-FAZA in Assessing Early Functional Response in Patients With Inoperable Non Small Cell Lung Cancer Undergoing Radiotherapy or Chemo-radiotherapy N/A
Completed NCT03320044 - Early Diagnosis of Small Pulmonary Nodules by Multi-omics Sequencing
Recruiting NCT03655015 - Patient-derived Organoid Model and Circulating Tumor Cells for Treatment Response of Lung Cancer
Completed NCT03741868 - Symptom Burden and Unmet Supportive Care Needs in Lung Cancer Patients Undergoing First or Second Line Immunotherapy
Not yet recruiting NCT05179408 - Telerehabilitation Following Lung Cancer N/A
Completed NCT03749512 - NLCR in Prediction of the Grade of Lung Tumor.
Recruiting NCT03664843 - Circulating Tumor DNA Longitudinal Monitoring in Stage III-IV Lung Cancer Patients
Completed NCT01261507 - Reader Study of DeltaView™ Chest Radiograph Software N/A