Left Ventricular Systolic Dysfunction Clinical Trial
Official title:
3D & Speckle Tracking Together as a Sensitive Marker for Early Outcome in Patients With Left Ventricular Dysfunction Undergoing Cardiac Surgery
Patients presenting with Left Ventricle (LV) dysfunction undergoing cardiac surgery are at increased risk of perioperative morbidity and mortality. LV dysfunction has been reported as an independent predictor of operative mortality in patients undergoing Cardiac surgery. It also often leads to low cardiac output states with many of these patients requiring inotropic or mechanical support and vasopressors for hours to days after surgery. Speckle tracking when combined with three dimensional (3D) imaging techniques might prove to be a more sensitive marker for ventricular dysfunction. The present study investigates early outcomes in a consecutive series of patients with LV dysfunction undergoing cardiac surgery
All patients inside operating room, a wide bore i/v access and radial artery will be
cannulated under local anesthesia. Standard opioid- propofol- relaxant based induction will
be followed. After endotracheal intubation, an adult 2D Trans Eesophageal Echocardiography
(TEE) probe (6VT-D probe of the GE vivid E9 echocardiography system (GE Medical Systems,
Hortein, Norway) will be inserted. A 7 Fr triple lumen catheter and 8.5 Fr introducer sheath
will be placed in the right internal jugular vein under ultrasound guidance. A 7 Fr
Pulmonary Artery Catheter (PAC) (Swan Ganz catheter, Edwards Life Sciences) will be floated
as per standard practice. Attempts to wedge will be discontinued if the catheter does not
wedge beyond 8 cm into the main pulmonary artery.
Surgery will be performed through a midline sternotomy on cardiopulmonary bypass with
bicaval cannulation and with intermittent antegrade warm blood cardioplegia. All surgical
procedures were performed by experienced surgeons using standardized techniques.
Cardiopulmonary bypass (CPB) and anaesthesia management will be performed according to our
standard operating procedures. Moderate hypothermic (28-32*C) CPB will be established with a
non-pulsatile flow of 2,5 l/min/m2 and an arterial pressure > 60 mmHg without additional
filtration. CPB will be primed with balanced electrolyte solution. Coagulation will be
offset by 400 IU/kg heparin aiming at an Activated Clotting Time (ACT) > 480 seconds.
Additionally, all patients will receive tranexamic acid 100mg/kg. Cardioplegic arrest will
be induced and maintained by intermittent administration of ante grade potassium enriched
solution.
Perioperative goal-oriented haemodynamic support (i.e. heart rate 80-100 beats/min, mean
arterial pressure 65-85 mmHg, central venous pressure (CVP) 8-12 mmHg at positive
end-expiratory pressure 5 cms of water, pulmonary artery occlusion pressure 12-15 mmHg,
cardiac index >2.5 l /min/m2 2, stroke volume index >30 ml/m, mixed venous oxygen saturation
>65) will be established according to institutional standards. Intraoperatively, patients
will be monitored with transoesophageal echocardiography (6VT-D probe of the GE vivid E9
echocardiography system (GE Medical Systems, Hortein, Norway)) and a pulmonary artery
catheter with or without continuous mixed venous oximetry measurement. In case of difficult
CPB separation despite hemodynamic optimization, an intraaortic balloon pump (IABP) will be
placed according to the team's assessment.
After chest closure, the patient will be transferred intubated and mechanically ventilated
in the ICU. Patients will be kept sedated with morphine administration (20-40 mcg/kg/min)
until cardiopulmonary stability is achieved, chest tube drainage is negligible (<100 ml/h),
and the patient is judged to be extubated. If mechanical ventilation is required > 12 hours,
sedation will be switched to midazolam (10-20 mcg/kg/min) combined with morphine (20-40
mcg/kg/min), and weaning from mechanical ventilation will be performed according to the
standard operating procedures at our hospital. Hemodynamic optimization will be continuously
accomplished according to the haemodynamic goals as mentioned above.
The decision for renal replacement therapy (RRT) will be taken in consultation with the
department of nephrology and based on the following criteria: a) oliguria < 500 ml/dl and/or
anuria < 100 ml/dl, b) metabolic acidosis, c) hyperkaliaemia, and d) uraemia.
Hemodynamic monitoring Once PAC is placed, baseline parameters will be recorded in mmHg.
Pressure will be defined as Pulmonary systolic pressure peak (PAPs), mean pressure (PAPm),
and Pulmonary Artery Wedge Pressure (PAWP).
These reading will be taken as baseline after placement of PAC. In addition usual vital
parameters such as mean blood pressure (MAP), CVP and heart rate (HR), will also be
acquired.
Systemic Vascular Resistance (SVR) and Cardiac Index (CI) calculation will be done as per
the standard protocol.
Time periods at which parameters will be evaluated After induction of anesthesia hemodynamic
and echocardiographic parameters will be taken. After induction, if the patients require
ionotropes and/or vasopressors it will be administered to achieve the haemodynamic goal as
mentioned above. The parameters will be obtained again after coming out of CPB. Patient will
be started on vasopressors- inotropic support as deemed fit by the treating
anaesthesiologist to achieve the haemodynamic goal.
End point of study: Either patient dies or discharged from the ICU as per the protocol.
Echocardiographic monitoring All patients in whom TEE probe is placed will undergo an
initial comprehensive TEE examination covering all the 28 standard views as per the American
Society of Echocardiography (ASE) guidelines. In addition, focused assessment for the study
parameters will be done after the completion of comprehensive examination.
Assessment of LV Comprehensive echocardiography will be performed before surgery using 6VT-D
probe of the GE vivid E9 echocardiography system (GE Medical Systems, Hortein, Norway),
including standard 2D views digitally stored at a high frame rate (>50 frames/s). All
measurements will be performed on line on the same machine by anaesthesiologist experienced
in TEE blinded to patient's outcome. Left ventricle (LV) volumes in systole and diastole and
LV Ejection Fraction (LVEF) will be computed using the Simpson biplane method from 2 chamber
(2C) and 4 chamber (4C) apical views. The endocardial borders will be traced for the
measurements and the papillary muscles will be excluded, as recommended in the guidelines. A
frame rate of >50 will be ensured during the measurements to ensure accurate endocardial
border detection. Foreshortening will be avoided by retroflexing the probe.
Speckle-tracking analysis will be performed to assess LV Global Longitudinal strain (GLS).
GLS will be computed using 2D-speckle-tracking analysis by automated function imaging (AFI)
measured from the three mid esophageal views (long-axis and two- and four-chamber views).
For strain processing, the peak of the R-wave on the electrocardiogram will be used as the
reference time point for end-diastole and segments with poor-quality tracking will be
manually discarded. GLS will only be computed from patients with >14 segments adequately
tracked for a 18-segment model. GLS will be calculated by averaging the peak strain values
of 18 segments. Three-dimensional LV volumes and EF will be measured from the 3D full-volume
data set. Using the on board GE software (GE vivid E9 echocardiography system (GE Medical
Systems, Hortein, Norway), the full-volume data of the LV will be organized into orthogonal
four-, two-chamber, and short-axis views. Enddiastolic and end-systolic frames will be
selected. Mitral annular and apical points will be placed on these images by adjusting the
axis. Semi-automated LV endocardial border detection software on the system will outline the
endocardial borders in these three planes. The software then uses sequence analysis to track
the endocardium in all frames and then automatically calculate a true 3D end diastolic
volume (EDV), end systolic volume (ESV), and EF from the moving 3D endocardial shell. The
endocardial borders could be adjusted manually if the endocardial border tracking is deemed
inadequate, and the sequence analysis will be repeated.
The diastolic function of the LV will be measured by measuring these parameters- the mitral
inflow velocity and the tissue Doppler velocity of the lateral mitral annulus. The mitral
inflow velocities (E & A) will be measured by placing the cursor for pulsed wave Doppler at
the tip of the mitral leaflet coaptation point. The sweep speed will be set at 25mm/s and
the scale will be adjusted and the baseline shifted above to obtain optimal waveforms.
Tissue Doppler measurements will be taken by placing the cursor of pulsed wave tissue
Doppler on the lateral mitral annulus. A frame rate of > 100m/s will be ensured by adjusting
the sector width and the measurements made at a sweep aped of 25mm/s.
Post valve replacements, the prosthetic valves will be evaluated as per recommendations for
evaluation of prosthetic valves. For all measurements of pulsed and continuous wave doppler
the cursor will be placed at an angle < 20' to the flow.
Every attempt will be made to make measurements in sinus rhythm. In case of a non-sinus
rhythm, measurements will be taken at the time when the ventricular rate is close to the
baseline. If that is not possible, then an average of 5-6 readings will be used for
analysis.
;
Observational Model: Cohort, Time Perspective: Prospective
Status | Clinical Trial | Phase | |
---|---|---|---|
Active, not recruiting |
NCT01058837 -
SCD-HeFT 10 Year Follow-up
|
N/A | |
Completed |
NCT00752752 -
The Acute Cardiovascular Effects of Marathon Running Using Magnetic Resonance Imaging
|
N/A | |
Recruiting |
NCT04166331 -
Adjunctive DobutAmine in sePtic Cardiomyopathy With Tissue Hypoperfusion
|
Phase 3 | |
Active, not recruiting |
NCT05764109 -
Adherence to Cied Implantation Guidelines and Cardiac Rehabilitation
|
||
Completed |
NCT05630170 -
The SMART-LV Pilot Study
|
N/A | |
Terminated |
NCT01969890 -
STem cElls Mobilization in Acute Myocardial Infarction Outcome Trial
|
Phase 3 | |
Recruiting |
NCT01747187 -
Cardiac Stress in Septic Shock - Biomarkers, Echocardiography and Outcome
|
N/A | |
Completed |
NCT01162083 -
Identifying an Ideal Cardiopulmonary Exercise Test Parameter
|
N/A | |
Completed |
NCT04221763 -
Mechanisms and Innovations in Cardiac Resynchronisation Therapy
|
N/A | |
Recruiting |
NCT06221891 -
Early Evaluation of Left Ventricular Systolic Function Impairment in Patients With Chronic Kidney Disease by Multimodal Ultrasonography
|
||
Completed |
NCT04231331 -
Ertugliflozin for Functional Mitral Regurgitation
|
Phase 3 | |
Completed |
NCT01500759 -
Sleep-Disordered Breathing in Heart Failure - The SchlaHF-Registry
|
||
Recruiting |
NCT05714085 -
Efficacy, Safety, and Pharmacokinetics of Vericiguat in Pediatric Participants With Heart Failure Due to Left Ventricular Systolic Dysfunction (MK-1242-036)
|
Phase 2/Phase 3 | |
Completed |
NCT01086124 -
Objective Systolic Function Recuperation Assessed by Echocardiography
|
N/A | |
Recruiting |
NCT06270498 -
Effect of Oral sucRosomIal Iron on exerciSE Capacity and Quality of Life in Patients With Heart Failure
|
Phase 4 | |
Completed |
NCT03470155 -
Operative Mitral Valve Reconstruction in Functional mv Insufficiency With Reduced Systolic Ventricle Function
|
||
Suspended |
NCT03755570 -
How is COGNItive Function Affected by Cardiac Resynchronisation Therapy?
|
||
Recruiting |
NCT04399447 -
Multicenter Normal Reference Study of Tissue Motion Tracking of Mitral Annular Displacement(TMAD)
|
||
Not yet recruiting |
NCT03993730 -
Cardiovascular Magnetic Resonance GUIDEd Insertion of Implantable Cardiac Defibrillator in Dilated CardioMyopathy
|
N/A | |
Active, not recruiting |
NCT01918215 -
Cardiac Magnetic Resonance GUIDEd Management of Mild-moderate Left Ventricular Systolic Dysfunction.
|
N/A |