Clinical Trials Logo

Clinical Trial Summary

The general objective of this study is to evaluate the accuracy of a novel smartphone application for jaundice screening (Picterus Jaundice Pro) in a population with high melanin content in the skin. The specific objectives for this study are: i. To assess the correlation between bilirubin level measurements obtained by Picterus Jaundice Pro with Total Serum Bilirubin (TSB), and TcB, in newborns with high melanin content in the skin. ii. To determine the accuracy of Picterus Jaundice Pro in newborns with high melanin content in the skin.


Clinical Trial Description

The goal for this project is to demonstrate that the Picterus Jaundice Pro screening method can be used to identify children with severe neonatal jaundice independent of skin color. Thus, providing a cheaper, patient-friendly, and more readily available method of neonatal jaundice detection. The long-term goal is that with the implementation of the app, the identification of newborns with severe jaundice will be improved and, thus, referred at an earlier stage for diagnostics and treatment. The study will be a cross-sectional study with quantitative methods of data collection. The study population will comprise 150 newborns from the Neonatal Unit and the maternity ward at Princess Marina Hospital. Parents to newborns with and without signs of jaundice will be asked to participate. Following informed consent, background data such as birth weight, age on examination, gestational age, and type of feeding will be obtained. Gestational age will be based on ultrasound determination and the last normal menstruation period (LNMP). The skin type of the infant will be classified according to the newborn Neomar's scale score. Transcutaneous bilirubin measurements will be performed over the sternum of the infant. A Dräger Jaundice Meter JM-105 will be used in this study. Skin reflectance will be measured using a portable Konica Minolta spectrophotometer CM-700d. A validated smartphone with Picterus Jaundice Pro will be used to collect digital images of skin of the infant chest together with the Picterus calibration card. After all the images are obtained, a unique ID will be displayed on the smartphone. This ID will be recorded on the case report forms and later used to pair clinical data and digital images. A blood sample to determine TSB will be obtained within 60 minutes of obtaining the images and processed at the Department of clinical biochemistry in the hospital laboratory. After completion of the study the bilirubin measurement from Picterus Jaundice Pro will be determined and compared to the TSB and TCB measurements using the Pearson correlation coefficient. Sub-analysis for the different skin colors will be performed. Systematic over- or under-estimation of bilirubin levels will be evaluated using Bland-Altman plots. Sensitivity and specificity analysis will be calculated for different cut-off values (ROC analysis). ;


Study Design


Related Conditions & MeSH terms


NCT number NCT06372093
Study type Interventional
Source Picterus AS
Contact
Status Completed
Phase N/A
Start date March 16, 2023
Completion date February 26, 2024

See also
  Status Clinical Trial Phase
Completed NCT00735319 - Transcutaneous Bilirubinometers in the Community N/A
Completed NCT00114543 - Trial of Aggressive Versus Conservative Phototherapy in Infants <1,000 Grams Birth Weight Phase 3
Withdrawn NCT04021927 - Development of a Neonatal Jaundice Treatment Accelerator by Redirection of Unused Light During Phototherapy N/A
Completed NCT01887327 - Stannsoporfin With Light Therapy for Newborn Babies With Jaundice Phase 2
Completed NCT04632888 - The Effect of Telephone Support for Breastfeeding Follow-up on Infantile Colic and Maternal Breastfeeding Self-efficacy N/A
Not yet recruiting NCT04527536 - Research of Diagnostic Value for BMJ Infants
Suspended NCT03741803 - Relationship Between Delayed Cord Clamping at Birth and Neonatal Bilirubin Levels in Parturients With a Prior Child Requiring Therapy for Neonatal Jaundice N/A
Completed NCT05650463 - Evaluation of a Smartphone-based Screening Tool (Picterus Jaundice Pro) for Neonatal Jaundice in Dark Skin Newborns N/A
Terminated NCT05623566 - Evaluation of a Smartphone Based Screening Tool for Neonatal Jaundice in Surabaya, Indonesia N/A
Completed NCT02612727 - Filtered Sunlight Phototherapy to Treat Significant Jaundice: Safety and Efficacy in Neonates N/A
Completed NCT01434810 - Treatment of Neonatal Jaundice With Filtered Sunlight Phototherapy: Safety and Efficacy in African Neonates N/A
Completed NCT03184948 - Understanding Neonatal Jaundice in Rwanda N/A
Completed NCT03942757 - BiLirubin Decrease Under Phototherapy Exposure in the Preterm Newborn in Incubator
Not yet recruiting NCT05806684 - Hyperbilirubinemia and Retinopathy of Prematurity in Preterm Infants: a Retrospective Study.
Completed NCT03570775 - Effectiveness, Safety and Perceptions With the Use of One LED Sleeping Bag Device in the Treatment of Neonatal Jaundice N/A
Completed NCT03569254 - Effectiveness, Safety and Perceptions With the Use of One LED Blanket Device in the Ambulatory Treatment of Jaundice N/A
Completed NCT05625880 - Evaluation of Bilirubin Estimates in Newborns From Smartphone Digital Images in a Nepali Population N/A
Completed NCT01169740 - Transcutaneous Measurement of Jaundice in the Newborn N/A
Not yet recruiting NCT06449508 - The Effectiveness of Probiotics in Neonatal Jaundice Phase 1/Phase 2
Completed NCT05623553 - Evaluation of a Smartphone Based Diagnostic Tool to Assess Neonatal Jaundice in a Mexican Population N/A