Clinical Trials Logo

Clinical Trial Summary

The performance and accuracy of the smartphone application (app) Picterus Jaundice Pro (PicterusJP) will be validated by a cross-sectional study conducted in low resource settings in Mexico. Physics-based and machine learning-based models will be used to analyze the images obtained with the app and its performance will be compared.


Clinical Trial Description

A cross-sectional prospective study is taken place at Hospital General de Zona 1 in the city of Oaxaca, Mexico. Participants are recruited from the maternity ward and emergency room and data collection is conducted by one experienced pediatrician and one paediatrics' resident. After informed consent is obtained, background data including time and date or birth, birth weight, gestational age, parent's skin type according to Fitzpatrick scale and newborn's skin color according to Neomar's scale is being collected. Visual assessment is performed by the researchers using Kramer's scale. To obtain the bilirubin measurements with the smartphone app Picterus Jaundice Pro (Picterus JP), the calibration card is placed on the newborn's chest and a set of six images, 3 with and 3 without flash, are captured. The smartphones used to capture the images are Samsung A23, iPhone 11 and iPhone 15 Pro. Total serum bilirubin (TSB) levels are measured with a blood sample obtained within one hour of capturing the images and analyzed at the hospital laboratory facilities. Demographic and clinical characteristics will be analyzed by descriptive statistic. Bilirubin measurements correlation between Picterus JP using both models and TSB will be determined by Pearson's correlation coefficient. Systematic over or underestimation of bilirubin levels will be evaluated using Bland-Altman plots. Accuracy measurements will be determined using receiver operating characteristics (ROC) and area under the curve (AUC) analysis. To compare the correlations from both models, Fisher's r to z transformation approach will be applied ;


Study Design


Related Conditions & MeSH terms


NCT number NCT06276582
Study type Interventional
Source Norwegian University of Science and Technology
Contact Gabriela Jimenez Diaz
Phone +4745914516
Email gabriela.j.diaz@ntnu.no
Status Recruiting
Phase N/A
Start date January 17, 2023
Completion date May 31, 2024

See also
  Status Clinical Trial Phase
Completed NCT00735319 - Transcutaneous Bilirubinometers in the Community N/A
Completed NCT00114543 - Trial of Aggressive Versus Conservative Phototherapy in Infants <1,000 Grams Birth Weight Phase 3
Withdrawn NCT04021927 - Development of a Neonatal Jaundice Treatment Accelerator by Redirection of Unused Light During Phototherapy N/A
Completed NCT01887327 - Stannsoporfin With Light Therapy for Newborn Babies With Jaundice Phase 2
Completed NCT04632888 - The Effect of Telephone Support for Breastfeeding Follow-up on Infantile Colic and Maternal Breastfeeding Self-efficacy N/A
Not yet recruiting NCT04527536 - Research of Diagnostic Value for BMJ Infants
Suspended NCT03741803 - Relationship Between Delayed Cord Clamping at Birth and Neonatal Bilirubin Levels in Parturients With a Prior Child Requiring Therapy for Neonatal Jaundice N/A
Completed NCT05650463 - Evaluation of a Smartphone-based Screening Tool (Picterus Jaundice Pro) for Neonatal Jaundice in Dark Skin Newborns N/A
Terminated NCT05623566 - Evaluation of a Smartphone Based Screening Tool for Neonatal Jaundice in Surabaya, Indonesia N/A
Completed NCT02612727 - Filtered Sunlight Phototherapy to Treat Significant Jaundice: Safety and Efficacy in Neonates N/A
Completed NCT01434810 - Treatment of Neonatal Jaundice With Filtered Sunlight Phototherapy: Safety and Efficacy in African Neonates N/A
Completed NCT03184948 - Understanding Neonatal Jaundice in Rwanda N/A
Completed NCT03942757 - BiLirubin Decrease Under Phototherapy Exposure in the Preterm Newborn in Incubator
Not yet recruiting NCT05806684 - Hyperbilirubinemia and Retinopathy of Prematurity in Preterm Infants: a Retrospective Study.
Completed NCT06372093 - Evaluation of Bilirubin Measurements in Newborns From Smartphone Digital Images in a Population in Botswana N/A
Completed NCT03569254 - Effectiveness, Safety and Perceptions With the Use of One LED Blanket Device in the Ambulatory Treatment of Jaundice N/A
Completed NCT03570775 - Effectiveness, Safety and Perceptions With the Use of One LED Sleeping Bag Device in the Treatment of Neonatal Jaundice N/A
Completed NCT05625880 - Evaluation of Bilirubin Estimates in Newborns From Smartphone Digital Images in a Nepali Population N/A
Completed NCT01169740 - Transcutaneous Measurement of Jaundice in the Newborn N/A
Not yet recruiting NCT06449508 - The Effectiveness of Probiotics in Neonatal Jaundice Phase 1/Phase 2