IUD Insertion Complication Clinical Trial
Official title:
Comparing Expulsion Rates When Using "Hang Up" Intrauterine Device Insertion Technique to Postplacental and Postpartum Insertion
the investigators are trying to determine if this method of intrauterine device (IUD) insertion "hang up technique" has less expulsion rates than 6 week insertion or immediate post-placental insertion.
This prospective multi-center clinical trial will be conducted at the Kasr Alainy maternity
hospital, and AL-Zahra university hospital after approval from both ethics committees was
obtained (OBGYN Scientific & ethics committee and Al-Zahra ethics committee). The study will
enroll pregnant women attending the antenatal care clinic who have been scheduled for
elective cesarean section after obtaining a signed informed consent from all participants.
The enrolled participants will be divided into 3 groups:
- Group A: will serve as our experimental group where the enrolled patients will have the
IUD applied in the middle of the uterine cavity and then attached to the fundus of the
uterus by an absorbable suture "Hang up technique" (Tjahjanto & Haryuni, 2014)
- Group B: will serve as our active comparator and will include patients where IUD will be
inserted after 6 weeks post-partum.
- Group C: will serve as our control group where the enrolled patients will have the IUD
just applied into the middle of the uterine cavity at the level of the fundus without
attachment.
Randomization will be done by a computer-generated randomization table, and assignment into
the various groups will be done by a sealed opaque envelope system which will be opened by
the circulating nurse in the operating room during cesarean section.
In both groups A and C, a Copper T-380 IUD (TCU 380 A with safe load PREGNA INTERNATIONAL
LTD® manufactured by PREGNA® - India) was placed in the middle of the uterine cavity, and the
threads was passed through the cervix after dilatation by one finger.
In group (A) Hang up technique will be done with the same technique of a previous study done
by Tjahjanto and Haryuni in 2014, but by using 2-0 Polyglactin 910 undyed braided absorbable
suture with a straight needle "KS 60mm reverse cutting" (VICRYL RAPIDEā¢ ETHICON®). The needle
will be inserted perpendicularly from the outside the uterus to penetrate the median of the
fundus wall to get into the uterine cavity. Once the surgical thread entered the uterine
cavity, the needle is clamped with rings forceps and pulled out through the lower uterine
segment incision. Subsequently, an anchor knot is made on the crossing arm so that the IUD is
balanced and hanging flexibly on the wall of the fundus. The IUD string is then cut in the
middle of the long thread. Using ring forceps for clamping the IUD, it is inserted into the
uterine cavity while simultaneously pulling the surgical thread out of the uterus so that the
IUDs horizontal arm is touching the uterine fundus. The position of IUD remains suspended by
the thread. Then, a knot is made on the outer surface of the uterus so the IUD will be fixed
and hangs from the fundus (Tjahjanto & Haryuni, 2014) The patients will be evaluated for
postpartum hemorrhage and fever 24 hours following the surgery. Patients will be re-evaluated
6 weeks, 3 and 6months postpartum for vaginal bleeding (irregular bleeding and menorrhagia),
vaginitis (smelly odor, discharge) PID (fever, ovarian abscess, hydro/pyo-salpinx).
Patients will also be re- evaluated by trans-vaginal ultrasound (US) to assess the position
of IUD inside uterine cavity at 24hours, also at 6 weeks, 3and 6 months post-operative.
Expulsion is defined when the IUD is not seen inside the uterine cavity by US and fundal
displacement is noted when distance between transverse limb of IUD and fundus more than 20mm.
If the acceptor does not arrive on time, they will be invoked by a call. If they cannot be
contacted or found until the end of the study they will be considered as loss of follow-up.
sample size: the investigators are planning a study of independent cases and controls with 1
control(s) per case. Prior data indicate that the probability of exposure among controls is
0.044. If the true probability of exposure among cases is 0. 24 (Chen et al, 2010). We will
need to study 49 case patients and 49 control patients to be able to reject the null
hypothesis that the exposure rates for case and controls are equal with probability (power)
0.8. The Type I error probability associated with this test of this null hypothesis is 0.05.
we will increase the number of participants to 54 in each group (10%) to allow for drop outs.
;
Status | Clinical Trial | Phase | |
---|---|---|---|
Not yet recruiting |
NCT03587077 -
Pain Relief During IUD Insertion in Women Delivered Only by Elective Cesarean Section
|
N/A | |
Completed |
NCT04080336 -
Comparison of Vaginal Misoprostol and Dinoprostone Prior to Copper Intrauterine Device Insertion in Nulliparous Women
|
Phase 4 | |
Recruiting |
NCT04474548 -
Postplacental LNG-IUD Ultrasound Use Study
|
N/A | |
Not yet recruiting |
NCT02706509 -
Pain Management Associated With the Insertion of Jaydess® in Nulliparous Women
|
Phase 4 | |
Recruiting |
NCT03828760 -
The Effectiveness of Music on Pain and Anxiety in IUD Insertion
|
N/A | |
Withdrawn |
NCT01967017 -
Study of Local Anesthesia as a Method to Decrease IUD Insertion Related Pain
|
Phase 4 | |
Completed |
NCT03111342 -
Intracervical Anesthesia and Pain Associated With Intrauterine Contraceptive Insertion
|
Phase 4 | |
Completed |
NCT04963582 -
LI4 Acupuncture for Analgesia in Intrauterine Device Insertion
|
N/A | |
Recruiting |
NCT02522130 -
Different Analgesics Prior to Intrauterine Device (IUD) Insertion: Is There Any Evidence?
|
N/A | |
Completed |
NCT05594108 -
Ultrasound-guided IUD Insertion During Family Medicine Residency Training
|
N/A | |
Recruiting |
NCT03939663 -
Role of Vaginal Misoprostol Prior to IUCD Insertion in Women Who Delivered Only by Elective Caesarean Section.
|
Phase 2 | |
Recruiting |
NCT05875571 -
Intravenous Ketorolac Administration to Attenuate Post-procedural Pain Associated With Intrauterine Device Placement
|
Phase 4 | |
Recruiting |
NCT05700812 -
IUD Placement Without Sounding
|
N/A | |
Not yet recruiting |
NCT03362905 -
Lidocaine for Pain Control During Intrauterine Device Insertion
|
Phase 4 | |
Completed |
NCT02716636 -
Fast Versus Slow Tenaculum Placement
|
N/A |