Intracranial Aneurysm Clinical Trial
— EMPOWEROfficial title:
ENTERPRISE 2 Vascular Reconstruction Device and Delivery System Registry: A Multicenter, Prospective, Single-arm Observational Study to Evaluate the Safety and Effectiveness With the Device to Facilitate Endovascular Coil Embolization of Intracranial Aneurysms
Verified date | June 2024 |
Source | Medos International SARL |
Contact | n/a |
Is FDA regulated | No |
Health authority | |
Study type | Observational |
The study is designed to evaluate the safety and effectiveness of ENTERPRISE 2 vascular reconstruction device and delivery system (hereinafter referred to as ENTERPRISE 2) to facilitate endovascular coil embolization of intracranial aneurysms.
Status | Active, not recruiting |
Enrollment | 164 |
Est. completion date | January 26, 2027 |
Est. primary completion date | April 22, 2022 |
Accepts healthy volunteers | No |
Gender | All |
Age group | 18 Years to 80 Years |
Eligibility | Inclusion Criteria: 1. Patient (or his/her legal representative) understands the nature of the procedure and provides voluntary written informed consent for the use of his/her peri-procedural and follow-up data; 2. Aged between 18 years and 80 years of age the time of consent; 3. Patient has been diagnosed with ruptured (Hunt-Hess Grade I-III) or unruptured intracranial aneurysm and requires the endovascular treatment; 4. Parent vessel with a diameter of =2.5 mm and =4 mm; 5. Patient is willing to return to the investigational site for the post-procedure follow-up evaluations. Exclusion Criteria: 1. Severe co-morbidity associated with a life-expectancy of less than twelve months as determined by the investigator; 2. Poor clinical condition with modified Rankin Scale (mRS) score =4; 3. Having prior or potential severe allergic reaction to contrast medium; 4. Known allergies to any of the device components, including Enterprise 2 and PROWLER® SELECT™ Plus Infusion Catheter; 5. Angiogram demonstrating that the aneurysm is not appropriate for endovascular treatment (i.e. severe intracranial vessel tortuosity, stenosis, intracranial vasospasm not responsive to medical therapy); 6. Arteriovenous malformation (AVM) in the territory of the target aneurysm; 7. Unsuitable for the antithrombotic and/or anticoagulant therapies; 8. Implantation of an intracranial stent associated with aneurysm or symptom distribution within 12 weeks prior to signature of Informed Consent Form; 9. Implantation of a carotid stent associated with aneurysm or symptom distribution within 12 weeks prior to signature of Informed Consent Form; 10. Evidence of active infection; 11. Pregnant or lactating women; 12. Having participated in clinical studies of other investigational drugs or devices within 30 days prior to signature of Informed Consent Form, excluding epidemiological studies of observational nature or natural history or not involving intervention; 13. Pre-planned staged procedure of target aneurysms. |
Country | Name | City | State |
---|---|---|---|
China | Beijing Anzhen Hospital, Capital Medical University | Beijing | Beijing |
China | Beijing Tiantan Hospital, Capital Medical University | Beijing | Beijing |
China | Zhujiang Hospital of Southern Medical University | Guangzhou | Guangdong |
China | Zhejiang Hospital | Hangzhou | Zhejiang |
China | The first affiliated hospital of Nanchang university | Nanchang | Jiangxi |
China | Nanjing Drum Tower Hospital | Nanjing | Jiangsu |
China | Huashan Hospital Shanghai Medical college, Fudan University | Shanghai | Shanghai |
China | Shengjing Hospital of China Medical University | Shenyang | Liaoning |
China | Union Hospital, Tongji Medical College, Huazhong University of Science & Technology | Wuhan | Hubei |
China | The first affiliated hospital of Zhengzhou university | Zhengzhou | Henan |
Lead Sponsor | Collaborator |
---|---|
Medos International SARL | Johnson & Johnson Medical (Shanghai) Ltd. |
China,
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Other | Incidence of disabling stroke or neurological death | Incidence of disabling stroke or neurological death = number of patients with disabling stroke or neurological death ÷ total number of patients receiving follow-up × 100%.
Stroke is defined as rapidly developing clinical signs of focal (or global) disturbance of cerebral function lasting more than 24 hours with no apparent cause other than of vascular origin, including ischemic stroke or hemorrhagic stroke (i.e., intraparenchymal hemorrhage (IPH), SAH, subdural hemorrhage (SDH), epidural hemorrhage (EDH)). Disabling stroke is defined as mRS score = 3 assessed at a minimum of 90 days (+/- 30 days) post-stroke event. Neurological death, also called brain death, refers to irreversible loss of the capacity for consciousness combined with the irreversible loss of all brainstem functions, including the capacity to breathe. |
at 180 days, at 1 year post procedure | |
Other | Incidence of in-stent thrombosis | Incidence of in-stent thrombosis = number of target aneurysms with parent vessel (in-stent) thrombosis during follow-up ÷ total number of target aneurysms receiving follow-up ×100%. | at 180 days, at 1 year post procedure | |
Other | Incidence of in-stent stenosis | Incidence of in-stent stenosis = number of target aneurysms with parent vessel (in-stent) stenosis during follow-up ÷ total number of target aneurysms receiving follow-up ×100%.
Mild, moderate, and severe in-stent stenosis is clinically defined as a stenosis of <33%, 33-67%, and =67%, respectively, comparing with non-stented parent vessel [43, 44]. In this study, moderate and severe in-stent stenoses (with a stenosis of =33%) of the parent vessel are defined as in-stent stenosis. |
at 180 days, at 1 year post procedure | |
Primary | Incidence of aneurysm recanalization | Incidence of aneurysm recanalization (at 180 days) = number of target aneurysm recanalization (at 180 days) ÷ total number of target aneurysms receiving follow-up × 100%. The results of aneurysm angiography at 180-day follow-up will be obtained through DSA, and the post-procedure immediate aneurysm recanalization shown in angiograms will be graded as per the Raymond-Roy Classification Scale.
The Raymond-Roy Classification at each follow-up time point increased by = one class relative to that immediately after the procedure is defined as recanalization (e.g., Class I immediately after the procedure, Class II at 180-day follow-up). |
at 180 days post procedure | |
Secondary | Incidence of aneurysm recanalization | Incidence of aneurysm recanalization (at 1 year) = number of target aneurysm recanalization (at 1 year) ÷ total number of target aneurysms receiving follow-up × 100%. The results of aneurysm angiography at 1 year follow-ups will be obtained through DSA or MRA or CTA. | at 1 year post procedure | |
Secondary | Successful stent/coil placement rate | Successful stent/coil placement rate = number of target aneurysms with successful stent/coil placement ÷ total number of target aneurysms× 100%.
Successful stent/coil placement is defined as successful stent deployment and successful delivery and placement of the coil at the target aneurysm assessed immediately post procedure through angiography. |
immediately post procedure | |
Secondary | Aneurysm occlusion | Aneurysm occlusion rate = number of target aneurysms with Raymond-Roy Class I or II aneurysm occlusion÷ total number of target aneurysms× 100%.
The aneurysm occlusion will be assessed by classifying the post-procedure immediate aneurysm occlusion shown in angiograms based on the Raymond-Roy Classification. |
immediately post procedure, at 180 days and at 1 year post procedure | |
Secondary | Incidence of retreatment | Incidence of retreatment = number of target aneurysms receiving retreatment during the follow-up ÷ total number of target aneurysms receiving follow-up ×100%.
Retreatment refers to any intervention to the target aneurysm after completing first stent-assisted coil embolization for the target aneurysm. |
at 30 days, 180 days, 1 year, 2 years, 3 years, 4 years and 5 years post procedure |
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT04870047 -
Coating to Optimize Aneurysm Treatment In The New Flow Diverter Generation
|
N/A | |
Recruiting |
NCT05968053 -
Detection of Microplastics and Nanoplastics in Neurosurgery Patients (DT-MiNi)
|
||
Not yet recruiting |
NCT05665309 -
Interest of Pre-operative Use of 3D Printing for Endovascular Treatment of Unruptured Intracranial Aneurysms With Intrasaccular Flow Disruptor
|
N/A | |
Completed |
NCT02783339 -
Neuroform Atlas Stent for Intracranial Aneurysm Treatment
|
||
Withdrawn |
NCT01194388 -
Axium Coil in Completing Endovascular Aneurysm Surgery Study
|
||
Completed |
NCT00071565 -
Familial Intracranial Aneurysm Study II
|
N/A | |
Recruiting |
NCT05409989 -
MicroVention, Inc. Flow Re-Direction Endoluminal Device X (FRED™ X™) Post-Approval Study
|
N/A | |
Completed |
NCT03680742 -
Contour Neurovascular System - European Pre-Market Unruptured Aneurysm
|
N/A | |
Completed |
NCT04872842 -
Establishment of Online Registration Platform for Unruptured Intracranial Aneurysms Based on 100 Regional Medical Centers in China and Population Follow-up Study
|
||
Terminated |
NCT02532517 -
Study to Evaluate the Safety and Effectiveness of the CODMAN ENTERPRISE® Vascular Reconstruction Device
|
N/A | |
Completed |
NCT03663257 -
Study to Evaluate Cerebral AneurysmFlow Results in Occlusion
|
||
Recruiting |
NCT06189950 -
Registration Trial of the Intracranial Visualized Stent for the Wide-necked Intracranial Aneurysms:REBRIDGE
|
N/A | |
Recruiting |
NCT05608122 -
Establishment of Online Registration Platform for Unruptured Intracranial Aneurysms Based on Regional Medical Centers in China and Population Follow-up Study (Phase Ⅱ)
|
||
Recruiting |
NCT03661463 -
Unruptured Intracranial Aneurysm Aspirin Trial (UIAAT).
|
Phase 2 | |
Completed |
NCT02609867 -
A Feasibility Study to Evaluate the Safety and Effectiveness of Implantation of Flowise Cerebral Flow Diverter (Flowise)
|
N/A | |
Active, not recruiting |
NCT02292017 -
Prospective Packing Density With Target Coils I
|
N/A | |
Active, not recruiting |
NCT01872741 -
Minipterional Versus Pterional Craniotomy
|
N/A | |
Completed |
NCT00993057 -
Efficiency of Two Glucose Sampling Protocols for Maintenance of Euglycemia
|
Early Phase 1 | |
Completed |
NCT00777907 -
Complete Occlusion of Coilable Aneurysms
|
Phase 3 | |
Completed |
NCT00777088 -
Pipeline for Uncoilable or Failed Aneurysms
|
N/A |