View clinical trials related to Intracranial Aneurysm.
Filter by:The primary objective of this registry is to assess the safety and angiographic outcomes of endovascular treatment of intracranial aneurysms using the DeltaMaxx Microcoil System.
Endovascular treatment with platinum coils is safe and effective in preventing rebleeding of intracranial aneurysms. Unfortunately, endovascular treatment of aneurysms with coils has been associated with incomplete occlusion at initial treatment (remnant) or at follow-up (recurrence). This in some studies has been as high as 20%. While many such aneurysm remnants or recurrences exhibit benign behavior, many require retreatment to prevent future hemorrhage. A recent randomized controlled trial of aneurysm coiling revealed that aneurysms between 2 and 9.9 mm diameter were more likely to have an improved angiographic and composite clinical outcome when treated with hydrogel-coated coils, an improvement inferred to result from higher packing density afforded by hydrogel expansion(1). The use of hydrogel coils is associated with technical difficulties related to expansion and limited time for deployment. The investigators theorize that similar results could be achieved by using more voluminous bare platinum coils, leading to improved packing density compared to smaller caliber coils, and thus result in lower incidence of remnants or residuals. The relationship between packing densities and composite clinical endpoints having never been shown in a robust fashion, the investigators therefore propose a randomized clinical trial opposing coiling with soft 15-caliber coils to 10-caliber bare platinum coils in aneurysms varying in size from 3 to 9.9 mm. To test the hypothesis that 15-caliber coiling systems are superior to standard 10-caliber coils in achieving better composite outcomes, the investigators propose the DELTA trial: Does Embolization with Larger coils lead to better Treatment of Aneurysms trial, a randomized controlled blinded trial with 2 subgroups of 282 patients each, 564 total: Subgroup 1: Coiled with a maximum proportion of 15-caliber coils as conditions allow Subgroup 2: Coiled with 10-caliber coils.
Endovascular treatment is now the first line treatment for the management of intracranial aneurysms. However aneurysm recanalization is an important limitation to this treatment. Several factors seems to be associated with aneurysm recanalization including medical history of the patient, aneurysm status (ruptured or unruptured), aneurysm size and location, modalities of treatment, immediate post-operative occlusion of the aneurysm. A precise knowledge of factors increasing the risk of aneurysm recanalization is quite important to optimize strategy of treatment and reduce the recanalization rate. No large, prospective, multicenter trial dealing with this question has been published in the literature.
To clarify whether amnesia after treatment of anterior communicating aneurysm (ACoA)is related to infarcts caused by occlusion or damage of the perforating artery of the ACoA, we used 3.0-T 3D high resolution MR imaging to identify and localize infarcts in patients with amnesia following treatment of ACoA aneurysm.
This study aims to determine if hormone replacement therapy, given during perimenopause may prevent the progression of saccular cerebral aneurysms.
Phase 1/2a Multicenter, Controlled, Randomized, Open Label, Dose Escalation, Safety, Tolerability, and Pharmacokinetic Study Comparing EG-1962 and Nimodipine in Patients with Aneurysmal Subarachnoid Hemorrhage
This study will evaluate the hypothesis that the administration of intraventricular tPA reduces the rates of cerebral vasospasm and ventriculoperitoneal shunt-dependent hydrocephalus in patients with aneurysmal subarachnoid hemorrhage.
This randomized prospective study was designed to compare the clinical, functional and aesthetic results of two surgical techniques for microsurgical clipping of anterior circulation aneurysms
Unruptured saccular intracranial aneurysms larger than 7 mm can be treated with endovascular occlusion using detachable coils, with or without expendable stent assistance. A new endovascular technique has recently been developed, using flow diverter stents without associated coils. Clinical results already published are encouraging but have to be confirmed. Furthermore, these medical devices are expensive in comparison to the coiling strategy. The purpose of this study is to compare the clinical efficacy, safety, and cost-effectiveness of endovascular coiling and endovascular flow diversion for unrupted saccular intracranial aneurysms.
Test single nucleotide polymorphisms (SNP's) in ruptured and unruptured aneurysm tissue to identify a genetic difference between the two types of aneurysms; and to test SNP's in arteriovenous malformation tissue to identify a genetic link.