View clinical trials related to Intervertebral Disc Degeneration.
Filter by:Multi-center, prospective nonrandomized study of treatment for 1 and 2 level degenerative disc disease between L2 and S1. Patients will be followed for a minimum of 2 years. The primary objective of this study to measure fusion success in patients with lumbar degenerative disc disease using the ATB and ALIF/FRA Spacer. The Secondary objective is evaluation of the patient's quality of life, pain and function.
The purpose of this study is to observe the overall satisfaction of patients with degenerative disc disease after receiving triple therapy.
The purpose of this study is to compare two doses of immunoselected, culture-expanded, nucleated, allogeneic adult MPCs when combined with hyaluronic acid to two control intradiscal injections in subjects with chronic low back pain due to moderate Degenerative Disc Disease (DDD) at one lumbar level from L1 to S1. All investigational subjects in this study will undergo injection of either 6 million (M) or 18M cells in a hyaluronic acid carrier into the degenerated lumbar disc's nucleus pulposus. All control subjects will undergo an intradiscal control injection with either saline or hyaluronic acid only
The purpose of this investigation is to evaluate the safety and effectiveness of the TRIUMPH® Lumbar Artificial Disc for the treatment of patients who are suffering from Degenerative Disc Disease (DDD) at one level from L1 to S1.
Study to show the safety, tolerability and preliminary effectiveness of Intradiscal rhGDF-5 in subjects with early lumbar disc degeneration
Study to show the safety, tolerability and preliminary effectiveness of Intradiscal rhGDF-5 in subjects with early lumbar disc degeneration.
Study to show the safety and tolerability of Intradiscal rhGDF-5 in subjects with early lumbar disc degeneration
The Satellite™ Retrospective Analysis is an international, retrospective, multi-center, non-interventional post-marketing study designed to document and analyze existing data with the device in a "real-world" setting. The purpose of this study is to evaluate number of adverse device effects (ADEs), serious adverse device effects (SADEs) and serious adverse event (SAEs) and early clinical effectiveness for the Satellite™ Nucleus Replacement in a standard clinical practice. Data collection will include information on health related quality of life (QoL), physical functioning and adverse event after nucleus replacement surgery. Radiographic measures will also be assessed to evaluate changes in disc height at the operated level and changes in segmental range of motion. All patients who were implanted with a Satellite™ Nucleus Replacement Prosthesis in the participating sites are eligible for participation in the Satellite ™ Retrospective Analysis.
The purpose of this study is to evaluate the safety and preliminary efficacy of NeoFuse in subjects with a diagnosis of degenerative disc disease (DDD) at 2 or more adjacent cervical vertebral levels between C3-C4 to C7-T1. All subjects in this study will undergo 2 or 3 level anterior cervical discectomy and fusion with Anterior Cervical Plate Fixation.
The purpose of this study is to evaluate the safety and preliminary efficacy of NeoFuse in subjects with a diagnosis of degenerative disc disease (DDD) at 2 or more adjacent cervical vertebral levels between C3-C4 to C7-T1. All subjects in this study will undergo 2 or 3 level anterior cervical discectomy and fusion with anterior cervical plate fixation.