View clinical trials related to Influenza B.
Filter by:This is an exploratory study of an influenza B challenge strain to determine the optimum infectious titer of challenge agent in healthy participants 18 to 55 years of age.
The goal of this prospective, digital randomized controlled trial is to evaluate the effectiveness of a predictive ILI detection algorithm and associated alerts during influenza season for adults living in the contigent United States. The main study objectives are to assess the effectiveness of predictive ILI detection algorithm and associated alerts on protective behaviors related to ILI and assess the accuracy of a predictive ILI detection algorithm using participant self-reported ILI symptoms and diagnosis.
The goal of this decentralized, observational study is to enroll and observe adults in the contingent United States during the 2023-2024 flu season. The main study objectives are to create a dataset of paired wearable data, self-reported symptoms, and respiratory viral infection (RVI) from PCR testing during the 2023-2024 flu season and to develop algorithm that is able to accurately classify asymptomatic and symptomatic RVI and understand the algorithm's performance metrics.
The Metrix COVID/Flu Test will be evaluated for use in Point-of-Care and Non-Laboratory settings in a home testing environment utilizing the clinical study design described herein. The study will take place in simulated home environments which will be set up within or near active clinical settings (e.g., urgent care facilities). This will be a prospective study conducted at three or more investigational sites located within the United States for the clinical validation of the Metrix COVID/Flu Test for the differential detection of SARS-CoV-2, Influenza A, and Influenza B in AN swab or saliva samples. Additional sites may be added to the study in order to meet minimum subject/sample enrollment requirements and geographic prevalence of respiratory virus infections. One or more investigational sites outside of the US (at which participants are required to be fluent in English) may also be included in the study depending on enrollment needs and geographical/seasonal prevalence of respiratory virus infections. Comparator testing will be performed to determine the infection status of each sample for comparison to results generated by the candidate test. The primary comparator for the study will be an FDA-cleared assay for the detection of SARS-CoV-2, Flu A, and/or Flu B.
The primary objective of this clinical performance study is to evaluate and further validate the clinical performance of: 1. ClariLight Influenza A/B & SARS-CoV-2 test kits and 2. ClariLight Influenza A/B & RSV test kits, for the qualitative detection and differential diagnosis of SARS-CoV-2, influenza A, influenza B, and respiratory syncytial virus (RSV) present in anterior nasal and oropharyngeal swab, in combination with an automated molecular diagnostic analyzer and sample collection tube by comparing them against a CE marked, in-vitro diagnostic device, used in the standard of care.
The study is designed as a prospective, multicentric, clinical study to investigate the positive percent agreement (PPA) and negative percent agreement (NPA) of the Panbio™ COVID-19/Flu A&B Panel using anterior nasal swab specimens tested directly, relative to the comparator methods, Roche cobas® SARS-CoV-2 (K231306) and Quidel Lyra® Influenza A+B Assay(K230236) (RT-PCR) in symptomatic patients suspected of respiratory viral infection by a healthcare provider.
This is a prospective multicenter study conducted to evaluate the performance of the LumiraDx SARS-CoV-2 & Flu A/B tests at point of care sites. Subjects presenting with symptoms suggestive of coronavirus disease 2019 (COVID-19) and Influenza at the time of the study visit will be enrolled and asked to donate swab sample(s) for testing on the device under evaluation.
The purpose of this study is to evaluate the usability of the MGC Health COVID-19 & Flu A+B Home Multi Test in home use.
This is a prospective multicenter study conducted to evaluate the performance of the LumiraDx SARS-CoV-2 Ag Ultra test in detecting severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and LumiraDx SARS-CoV-2 & Flu A/B test in differential detection of SARS-CoV-2, Influenza A (Flu A) and Influenza B (Flu B) at point of care sites. Subjects presenting with symptoms suggestive of coronavirus disease 2019 (COVID-19) and/or Influenza at the time of the study visit will be enrolled and asked to donate swab sample(s) for testing in the device(s) under evaluation.
Scarce information exists in relation to the effect of supplementation of Vitamin D3 in SARS-COV-2 infection, H1N1, and A, B Influenza when 25-hydroxyvitamin levels are between 20-100ng/ml. This study will evaluate the effect of supplementation of vitamin D3 vs. dietary-hygiene measures in SARS-COV-2 , H1N1, A, B Influenza infection rate in patients with serum 25-hydroxyvitamin D3 levels >20ng/ml. A comparative randomized study that will evaluate the effect of a monthly supplementation with 52000 units of Vitamine D3 during three months vs hygienic-dietary measures in the development of respiratory infections such as COVID-19, H1N1, A, B Influenza during 6 months of follow-up in health workers from a hospital in Northern Mexico with serum vitamin D values +/- 20ng/ml. Also, patients that during screening have 25-hydroxyvitamin D3 levels <20 ng/ml will receive vitamin D supplementation according to primary care discretion for three months and will be followed for 6 months and infection rate will be analyzed and compared.