Diabetes Mellitus Clinical Trial
Official title:
Does Variation in Mean Red Cell Age Impact HbA1C Interpretation?
Prevention of complications in veterans with diabetes depends heavily on assessment of blood glucose and HbA1c. The HbA1c is a blood test that measures the exposure of hemoglobin (Hb) to a person's average blood glucose over the lifespan of a red blood cell (RBC). The test is heavily relied upon as a measure of blood glucose control. It is normally assumed that all people (those with and without diabetes) have a narrow range of red blood cell survival. It has been recently shown that this is not a valid assumption. A more precise test of red blood cell survival, using a biotin label method, demonstrated a substantial difference of red blood cell survival among otherwise normal people. There is sufficient difference in red blood cell survival to alter the estimate of glycemic control from the HbA1c test by as much as 30 per cent. This introduces concern that HbA1c values do not mean the same thing in a significant number of people. Although the evidence is clear that there is variation in RBC survival among people, attributing this variation to differences between individuals depends on answering several simple questions which surprisingly remain unanswered: whether RBC survival is stable over time within an individual and whether blood glucose control affects its stability. Therefore, the goal of the proposed studies is to define these characteristics.
The first Specific Aim tests the hypothesis that mean RBC age is stable in subjects without diabetes and in subjects with diabetes at stable glycemic control. The second Specific Aim tests the hypothesis that mean RBC age will not change in subjects with diabetes studied initially in poor glycemic control, and again after being treated to stable, improved glycemic control for >8 months. To accomplish the two aims, RBC survival and mean blood glucose will be determined at two times separated by at least eight months in 10 subjects without diabetes, 10 subjects with diabetes and stable glycemic control, and up to 15 subjects with diabetes in initial poor glycemic control in order to re-study 10 subjects subsequently in improved glycemic control. The RBC survival will be measured using the same novel biotin RBC label in conjunction with mean glucose determination by continuous glucose monitoring. Mean blood glucose will be assessed using blood glucose testing meter , continuous glucose monitoring equipment, HbA1c, fructosamine and glycated albumin determinations HbA1c is the most highly valued clinical test for long term monitoring of glycemic control and the prediction of diabetes complications risk is relied upon for hundreds of thousands of clinical decisions made every year in veterans with diabetes. The proposed studies, by further defining RBC survival stability necessary to develop a new approach to HbA1c interpretation, therefore has the potential to dramatically support the Department of Veterans Affairs in its mission to reduce the burden of diabetes and its complications ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT03743779 -
Mastering Diabetes Pilot Study
|
||
Completed |
NCT03786978 -
Pharmaceutical Care in the Reduction of Readmission Rates in Diabetes Melitus
|
N/A | |
Completed |
NCT01804803 -
DIgital Assisted MONitoring for DiabeteS - I
|
N/A | |
Completed |
NCT05039970 -
A Real-World Study of a Mobile Device-based Serious Health Game on Session Attendance in the National Diabetes Prevention Program
|
N/A | |
Completed |
NCT04507867 -
Effect of a NSS to Reduce Complications in Patients With Covid-19 and Comorbidities in Stage III
|
N/A | |
Completed |
NCT04068272 -
Safety of Bosentan in Type II Diabetic Patients
|
Phase 1 | |
Completed |
NCT03243383 -
Readmission Prevention Pilot Trial in Diabetes Patients
|
N/A | |
Completed |
NCT03730480 -
User Performance of the CONTOUR NEXT and CONTOUR TV3 Blood Glucose Monitoring System (BGMS)
|
N/A | |
Recruiting |
NCT02690467 -
Efficacy, Safety and Acceptability of the New Pen Needle 34gx3,5mm.
|
N/A | |
Completed |
NCT02229383 -
Phase III Study to Evaluate Safety and Efficacy of Added Exenatide Versus Placebo to Titrated Basal Insulin Glargine in Inadequately Controlled Patients With Type II Diabetes Mellitus
|
Phase 3 | |
Completed |
NCT06181721 -
Evaluating Glucose Control Using a Next Generation Automated Insulin Delivery Algorithm in Patients With Type 1 and Type 2 Diabetes
|
N/A | |
Completed |
NCT05799976 -
Text Message-Based Nudges Prior to Primary Care Visits to Increase Care Gap Closure
|
N/A | |
Recruiting |
NCT04489043 -
Exercise, Prediabetes and Diabetes After Renal Transplantation.
|
N/A | |
Withdrawn |
NCT03319784 -
Analysis for NSAID VS Corticosteroid Shoulder Injection in Diabetic Patients
|
Phase 4 | |
Completed |
NCT03542084 -
Endocrinology Auto-Triggered e-Consults
|
N/A | |
Completed |
NCT02229396 -
Phase 3 28-Week Study With 24-Week and 52-week Extension Phases to Evaluate Efficacy and Safety of Exenatide Once Weekly and Dapagliflozin Versus Exenatide and Dapagliflozin Matching Placebo
|
Phase 3 | |
Recruiting |
NCT05544266 -
Rare and Atypical Diabetes Network
|
||
Completed |
NCT01892319 -
An International Non-interventional Cohort Study to Evaluate the Safety of Treatment With Insulin Detemir in Pregnant Women With Diabetes Mellitus. Diabetes Pregnancy Registry
|
||
Completed |
NCT05031000 -
Blood Glucose Monitoring Systems: Discounter Versus Brand
|
N/A | |
Recruiting |
NCT04039763 -
RT-CGM in Young Adults at Risk of DKA
|
N/A |