Hypoxia Clinical Trial
Official title:
Verification of Investigational Pulse Oximetry Devices During Motion and Non-Motion Conditions in Adult Volunteers
NCT number | NCT06415786 |
Other study ID # | MDT23026OM2VMT |
Secondary ID | |
Status | Completed |
Phase | |
First received | |
Last updated | |
Start date | March 7, 2024 |
Est. completion date | March 27, 2024 |
Verified date | April 2024 |
Source | Medtronic - MITG |
Contact | n/a |
Is FDA regulated | No |
Health authority | |
Study type | Observational |
The verification of an investigational pulse oximetry board to verify pulse rate and saturation accuracy over a specified saturation range in diverse populations.
Status | Completed |
Enrollment | 30 |
Est. completion date | March 27, 2024 |
Est. primary completion date | March 27, 2024 |
Accepts healthy volunteers | Accepts Healthy Volunteers |
Gender | All |
Age group | 18 Years to 50 Years |
Eligibility | Inclusion Criteria: 1. Male or female subjects 18 to 50 years of age 2. Subject is willing and able to comply with study procedures and duration 3. Subject is willing to sign an informed consent 4. Subject weighs >40kg 5. Subject is a non-smoker or has not smoked within 2 days prior to the study 6. Cleared same day health assessment form and health screening 7. Successful perfusion index ulnar/ulnar+radial ratio test showing adequate collateral blood flow. Exclusion Criteria: 1. Subject is considered as being morbidly obese (defined as BMI >39.5) 2. Compromised circulation, injury, or physical malformation of fingers, hands, ears or forehead/skull or other sensor sites which would limit the ability to test sites needed for the study (Note: Certain malformations may still allow subjects to participate if the condition is noted and would not affect the sites utilized) 3. Females of childbearing potential who are pregnant, who are trying to get pregnant, or who have a urine test positive for pregnancy on the day of the study 4. Subjects with COHb levels >3% as assessed by CO-Oximetry during the procedure 5. tHb < 10 g/dl as assessed by CO-Oximetry during the procedure 6. MetHb = 2% as assessed by CO-Oximetry during the procedure 7. Subjects with known respiratory conditions such as: 1. uncontrolled / severe asthma 2. flu or influenza type infection 3. pneumonia / bronchitis 4. shortness of breath / respiratory distress 5. unresolved respiratory or lung surgery 6. emphysema, COPD, lung disease 7. recent COVID (last 2 months) 8. Subjects with known heart or cardiovascular conditions such as: 1. hypertension: systolic >140mmHg, or Diastolic >90mmHg on 3 consecutive readings 2. have had cardiovascular surgery 3. chest pain (angina) 4. heart rhythms other than a normal sinus rhythm or with respiratory sinus arrhythmia (reviewed during health screen) 5. previous heart attack 6. blocked artery 7. unexplained shortness of breath 8. congestive heart failure (CHF) 9. history of stroke 10. transient ischemic attack 11. carotid artery disease 12. myocardial ischemia 13. myocardial infarction 14. cardiomyopathy 15. implantable active medical device such as pacemaker or automatic defibrillator 9. Self-reported health conditions as identified in the Health Assessment Form 1. diabetes 2. uncontrolled thyroid disease 3. kidney disease / chronic renal impairment 4. history of seizures (except childhood febrile seizures) 5. epilepsy 6. history of unexplained syncope 7. recent history of frequent migraine headaches 8. recent symptomatic head injury, within the last 2 months 9. cancer requiring chemotherapy, radiation, or current treatment 10. subjects with known clotting disorders 11. history of bleeding disorders or personal history of prolonged bleeding from injury 12. history of blood clots 13. hemophilia 14. sickle cell trait or disease 15. current use of blood thinner: prescription or daily use of aspirin 16. subjects with Severe contact allergies to standard adhesives, latex or other materials found in pulse oximetry sensors, ECG electrodes, respiration monitor electrodes or other medical sensors 17. participants with severe allergy to iodine (only applicable if iodine is used) 18. subjects with prior or known severe allergies to lidocaine (or similar pharmacological agents, e.g. Novocain) or heparin 19. arterial cannulation within the last 30 days prior to study date, (this may exclude only one radial artery site, left or right) 20. history of clinically significant complications from previous arterial cannulation 21. unwillingness or inability to remove colored nail polish or colored artificial nails other than clear from test digits 22. other known health condition, upon disclosure in Health Assessment form |
Country | Name | City | State |
---|---|---|---|
United States | Element | Louisville | Colorado |
Lead Sponsor | Collaborator |
---|---|
Medtronic - MITG |
United States,
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | Verification of saturation accuracy during motion and non-motion conditions | Saturation accuracy in a diverse subject population over a specified saturation range during motion and non-motion conditions.
The acceptance criteria for the Nellcor™ Pro 7 Pulse Oximetry PCBA are as follows: The acceptance criteria for SpO2 during motion and non-motion conditions across the saturation range of 70-100%: Motion: SpO2 Max-A ±3% (ARMS) Max-N ±3% (ARMS) OxySoft-N ±3% (ARMS) Non-Motion: SpO2 SC-A ±2 % (ARMS) |
2.5 hours | |
Primary | Verification of Pulse Rate during motion and non-motion conditions | The acceptance criteria for pulse rate during motion and non-motion conditions from 20-250 BPM over a specified saturation range of 70-100%:
Motion: Pulse Rate Max-A =5% BPM (ARMS) Max-N =5% BPM (ARMS) OxySoft-N =5% BPM (ARMS) Non-Motion: Pulse Rate SC-A =3% BPM (ARMS) |
2.5 hours |
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT04498598 -
Structural Modification In Supraglottic Airway Device
|
N/A | |
Completed |
NCT05532670 -
N600X Low Saturation Accuracy Validation
|
||
Enrolling by invitation |
NCT04106401 -
Intravascular Volumes in Hypoxia During Antarctic Confinement
|
N/A | |
Recruiting |
NCT05883137 -
High-flow Nasal Oxygenation for Apnoeic Oxygenation During Intubation of the Critically Ill
|
||
Not yet recruiting |
NCT05817448 -
Hypoxia-induced Autophagy in the Pathogenesis of MAP
|
||
Recruiting |
NCT02661152 -
DAHANCA 30: A Randomized Non-inferiority Trial of Hypoxia-profile Guided Hypoxic Modification of Radiotherapy of HNSCC.
|
Phase 3 | |
Terminated |
NCT02801162 -
Evaluation of Accuracy and Precision of a New Arterial Blood Gas Analysis System Blood in Comparison With the Reference Standard
|
N/A | |
Completed |
NCT02943863 -
Regional Ventilation During High Flow Nasal Cannula and Conventional Nasal Cannula in Patients With Hypoxia
|
N/A | |
Not yet recruiting |
NCT02201875 -
Intrinsic Periodic Pattern of Breathing
|
N/A | |
Completed |
NCT02105298 -
Effect of Volume and Type of Fluid on Postoperative Incidence of Respiratory Complications and Outcome (CRC-Study)
|
N/A | |
Completed |
NCT01922401 -
Inverse Ratio Ventilation on Bariatric Operation
|
N/A | |
Active, not recruiting |
NCT01681238 -
Goal-directed Therapy in High-risk Surgery
|
N/A | |
Completed |
NCT01463527 -
Using Capnography to Reduce Hypoxia During Pediatric Sedation
|
N/A | |
Completed |
NCT01507623 -
Value of Capnography During Nurse Administered Propofol Sedation (NAPS)
|
N/A | |
Withdrawn |
NCT00638040 -
The Gene Expression Studies of the Role of Tumor Microenvironments in Tumor Progression
|
N/A | |
Active, not recruiting |
NCT06097754 -
Intermittent Exogenous Ketosis (IEK) at High Altitude
|
N/A | |
Completed |
NCT04589923 -
The VISION-Acute Study
|
||
Completed |
NCT05044585 -
Evaluation of RDS MultiSense® in Desaturation Analysis in Healthy Volunteers
|
N/A | |
Completed |
NCT03659513 -
The Effect of ECMO on the Pharmacokinetics of the Drugs and Their Clinical Efficacy
|
||
Completed |
NCT03221387 -
Sleep and Daytime Use of Humidified Nasal High-flow Oxygen in COPD Outpatients
|
N/A |