Clinical Trials Logo

Clinical Trial Summary

Cardiac Resynchronization Therapy (CRT) decreases heart failure hospitalizations and mortality and increases left ventricular Ejection Fraction (EF) in patients with dilated cardiomyopathy, left bundle branch block and QRS duration >130msec. His bundle pacing has a similar effect in this category of patients. However, CRT is not beneficial in heart failure (HF) patients with narrow QRS. His-bundle pacing delivers physiological ventricular activation and has been shown to improve acute hemodynamic function in patients with heart failure, a prolonged PR interval, and either a narrow QRS or RBBB through AV delay optimization. We observed an acute hemodynamic effect during application of higher pacing output (3.5 Volts/1 msec) in HF patients with dilated or ischemic cardiomyopathy and narrow QRS independently of the paced QRS duration or AV delay shortening. This is a single-center, prospective randomized single-blinded study, recruiting a sub-population of patients with heart failure (dilated or ischemic cardiomyopathy, EF<50%, narrow QRS (<110 msec), in optimal medical treatment who have an indication for ICD.


Clinical Trial Description

Cardiac Resynchronization Therapy (CRT) decreases heart failure hospitalizations and mortality and increases left ventricular Ejection Fraction (EF) in patients with dilated cardiomyopathy, left bundle branch block and QRS duration >130msec. His bundle pacing has a similar effect in this category of patients. However, CRT is not beneficial in heart failure (HF) patients with narrow QRS. His-bundle pacing delivers physiological ventricular activation and has been shown to improve acute hemodynamic function in patients with heart failure, a prolonged PR interval, and either a narrow QRS or Right Bundle Branch Block (RBBB) through atrioventricular (AV) delay optimization. We observed an acute hemodynamic effect during application of higher pacing output (3.5 Volts/1 msec) in HF patients with dilated or ischemic cardiomyopathy and narrow QRS independently of the paced QRS duration or AV delay shortening. This is a single-center, prospective randomized single-blinded study, recruiting a sub-population of patients with heart failure (dilated or ischemic cardiomyopathy, EF<50%, narrow QRS (<110 msec), in optimal medical treatment who have an indication for ICD. All patients will be implanted with a CRT (Cardiac Resynchronization Therapy) defibrillator with one of the leads positioned on the His bundle to obtain direct His-bundle capture. (There will be a 1-month run-in period where the output voltage will be 3.5 Volts/1 or 2V/1msec according to the group so as to obtain stable threshold). A single-blinded design will then be employed to investigate the effect of His bundle pacing. Patients will be allocated in random order to six-month treatment periods in each of the following two states (1) 3.5 Volts/1 msec pacing output direct His-bundle pacing, AV delay will be programmed in order to obtain a PR interval of 120-140msec; (2)back up only pacing (pacemaker programmed to VVI 30 bpm or AAI(R-DDD(R) 60bpm). Endpoint measurements will be taken at baseline, 1 month run-in period of 3.5 Volts/1 msec or 2V/1msec pacing output and 6 months post randomization. Treating Physicians will be aware of assignment in order to facilitate routine device follow-up. Echocardiographic and electrocardiographic evaluation will be performed in a blinded manner. Treatment allocation will be blinded to the endpoint assessor and the patient. Patients entering the study will attend for implantation of a CRT pacemaker device with one lead positioned on the His bundle. This will be performed in Miulli General Hospital (and other participating centres) no later than 2 months after the patient's screening visit. Before the intervention patients will be randomized to either receive active pacing treatment with 3.5 V/1 msec or back up only pacing (pacemaker programmed to VVI 30 bpm or AAI(R)-DDD(R) 60) for 6 months. All patients will be implanted with an Implantable cardioverter defibrillator (ICD) and an ICD lead in the right ventricle (RV) (either RV apex or RV septum). In all patients a pacing lead will be positioned in the right atrium (typically the right atrial appendage). All patients will have a pacemaker lead positioned on the His bundle to obtain direct His-bundle capture. After implantation of the device there will be a 1-month run-in period that the device will be programmed to deliver His bundle pacing therapy during this period at 3.5 Volts/1msec or 2V/1msec according to the assignment group. One month after patients are implanted with their device, patients will either receive active pacing treatment with 3.5 V/1 msec or back up only pacing (pacemaker programmed to VVI 30 bpm or AAI(R)-DDD(R) 60bpm) for 6 months. Treatment allocation will be obtained using an Interactive Web Response System (IWRS) programmed with a randomization schedule provided by the trial statistician. Appropriate blocking will be used. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05491655
Study type Interventional
Source Miulli General Hospital
Contact Grigorios Katsouras, MD, MSc
Phone 0803054219
Email g.katsouras@miulli.it
Status Recruiting
Phase N/A
Start date March 29, 2023
Completion date February 2025

See also
  Status Clinical Trial Phase
Recruiting NCT05650307 - CV Imaging of Metabolic Interventions
Recruiting NCT05654272 - Development of CIRC Technologies
Recruiting NCT05196659 - Collaborative Quality Improvement (C-QIP) Study N/A
Active, not recruiting NCT05896904 - Clinical Comparison of Patients With Transthyretin Cardiac Amyloidosis and Patients With Heart Failure With Reduced Ejection Fraction N/A
Completed NCT05077293 - Building Electronic Tools To Enhance and Reinforce Cardiovascular Recommendations - Heart Failure
Recruiting NCT05631275 - The Role of Bioimpedance Analysis in Patients With Chronic Heart Failure and Systolic Ventricular Dysfunction
Enrolling by invitation NCT05564572 - Randomized Implementation of Routine Patient-Reported Health Status Assessment Among Heart Failure Patients in Stanford Cardiology N/A
Enrolling by invitation NCT05009706 - Self-care in Older Frail Persons With Heart Failure Intervention N/A
Recruiting NCT04177199 - What is the Workload Burden Associated With Using the Triage HF+ Care Pathway?
Terminated NCT03615469 - Building Strength Through Rehabilitation for Heart Failure Patients (BISTRO-STUDY) N/A
Recruiting NCT06340048 - Epicardial Injection of hiPSC-CMs to Treat Severe Chronic Ischemic Heart Failure Phase 1/Phase 2
Recruiting NCT05679713 - Next-generation, Integrative, and Personalized Risk Assessment to Prevent Recurrent Heart Failure Events: the ORACLE Study
Completed NCT04254328 - The Effectiveness of Nintendo Wii Fit and Inspiratory Muscle Training in Older Patients With Heart Failure N/A
Completed NCT03549169 - Decision Making for the Management the Symptoms in Adults of Heart Failure N/A
Recruiting NCT05572814 - Transform: Teaching, Technology, and Teams N/A
Enrolling by invitation NCT05538611 - Effect Evaluation of Chain Quality Control Management on Patients With Heart Failure
Recruiting NCT04262830 - Cancer Therapy Effects on the Heart
Completed NCT06026683 - Conduction System Stimulation to Avoid Left Ventricle Dysfunction N/A
Withdrawn NCT03091998 - Subcu Administration of CD-NP in Heart Failure Patients With Left Ventricular Assist Device Support Phase 1
Recruiting NCT05564689 - Absolute Coronary Flow in Patients With Heart Failure With Reduced Ejection Fraction and Left Bundle Branch Block With Cardiac Resynchronization Therapy