Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT04798742
Other study ID # Gluteus maximus transfer
Secondary ID
Status Completed
Phase N/A
First received
Last updated
Start date February 1, 2012
Est. completion date September 17, 2018

Study information

Verified date July 2021
Source Göteborg University
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

Gluteus maximus transfer following THA does not improve abductor strength - a case-control gait analysis study of 15 patients with gluteus medius disruption The investigators have compared 15 gluteus maximus transferred patients with the use of a gait analysis system based on reflective markers and force plates to objectively evaluate the gait performance pre- and postoperatively.


Description:

The gluteus maximus flap transfer (GMT) is a surgical technique to improve gait kinematics and kinetics as well as reduce pain and ameliorate functional outcome in patients with hip abductor deficiency of the gluteus medius following total hip arthroplasty (THA). The investigators used a gait analysis system based on reflective markers and force plates to objectively evaluate gait performance pre- and postoperatively. Methods Gait analysis was performed in 15 patients who underwent GMT and were examined with an optical tracking system before and at a minimum of 13 months after the operation. Mean age was 69 years (SD=11), all were females. Median follow-up time was 24 (13-60) months. The primary outcome was hip abduction moment (Nm/kg) during gait. The control group consisted of 66 subjects without any gait pathology.


Recruitment information / eligibility

Status Completed
Enrollment 15
Est. completion date September 17, 2018
Est. primary completion date September 17, 2018
Accepts healthy volunteers Accepts Healthy Volunteers
Gender Female
Age group N/A and older
Eligibility Inclusion Criteria: - Patients with hip abductor deficiency of the gluteus medius following total hip arthroplasty (THA) Exclusion Criteria: - THA prior to the muscle transfer

Study Design


Related Conditions & MeSH terms


Intervention

Procedure:
Gluteus maximus transfer
Gait analysis study of 15 patients with gluteus medius disruption

Locations

Country Name City State
Sweden Roland Zügner Gothenburg

Sponsors (1)

Lead Sponsor Collaborator
Göteborg University

Country where clinical trial is conducted

Sweden, 

References & Publications (1)

Whiteside LA. Surgical technique: Transfer of the anterior portion of the gluteus maximus muscle for abductor deficiency of the hip. Clin Orthop Relat Res. 2012 Feb;470(2):503-10. doi: 10.1007/s11999-011-1975-y. — View Citation

Outcome

Type Measure Description Time frame Safety issue
Primary Abductor strength measurement with use of an optical tracking system after Gluteus maximus transfer - a case-control gait analysis study of 15 patients pre- and postoperative with gluteus medius disruption Gait analysis examination/measure will be performed preoperative with an optical tracking system in a gait laboratory using reflective markers and integrated force plates in order to record kinetics (Nm/kg) of abductor muscles moment in the frontal plane. Preop
Primary Abductor strength measurement with use of an optical tracking system after Gluteus maximus transfer- a case-control gait analysis study of 15 patients pre- and postoperative with gluteus medius disruption Gait analysis examination/measure will be performed 2 year postoperative with an optical tracking system in a gait laboratory using reflective markers and integrated force plates in order to record kinetics (Nm/kg) of abductor muscles moment in the frontal plane. Postop 2 year
See also
  Status Clinical Trial Phase
Recruiting NCT05556759 - Anterior Iliopsoas Muscle Space Block Versus Supra-iliac Anterior Quadratus Lumborum Block in Total Hip Arthroplasty N/A
Withdrawn NCT05030688 - Fascia Iliaca Compartment Block and PENG Block for Hip Arthroplasty N/A
Not yet recruiting NCT05015517 - ESP Block vs FIB in Patients Undergoing Hip Arthroplasty N/A
Completed NCT05134207 - The Effect of Oral Carbohydrate Solution on Anxiety and Comfort in Patients Undergoing Hip Arthroplasty N/A
Recruiting NCT04438265 - Quadratus Lumborum Type 2 as Chronic Hip Pain Treatment
Recruiting NCT04229368 - Effect of Vitamin D Status and Repletion on Postoperative Total Joint Arthroplasty Complications N/A
Active, not recruiting NCT05142462 - Post Market Clinical Follow-up of EUROSCUP Fixe Acetabular Cup
Completed NCT06083428 - Erector Spinae vs. PENG Block for Total Hip Arthroplasty Phase 4
Completed NCT05396924 - Rectal Temperature Measurement in Detecting Hypothermia During Hip Arthroscopy N/A
Active, not recruiting NCT05524363 - Assessment of Safety and Performances of HYPE SCS Stem Associated to NOVAE Sunfit TH Acetabular Cup in Hip Arthroplasty
Recruiting NCT06147401 - Comparison of PENG Associated With LFCN Block Versus FICB for Multimodal Analgesic Management in THA N/A
Completed NCT03977454 - Periarticular Injection Versus Peripheral Nerve Block in Total Hip Arthroplasty Phase 2
Recruiting NCT05397145 - Iliopsoas Plane Block vs PENG Block for Hip Arthroplasty N/A
Completed NCT03981354 - Nutritional Status and Its Modifications After Hip Replacement
Recruiting NCT06257160 - Superiority Randomized Controlled Trial of Ultrasound-guided PENG Block Compared to Surgical Infiltration in the Analgesia of Posterior Total Hip Arthroplasty Surgery N/A
Active, not recruiting NCT04995822 - Post Market Clinical Follow-up of EUROSTEM Femoral Stem
Completed NCT04883788 - The Impact of COVID-19 Pandemic on Hip and Knee Replacement
Not yet recruiting NCT06317870 - Pericapsular Nerve Block Versus Intrathecal Morphine for Analgesia After Primary Hip Arthroplasty N/A
Completed NCT03541798 - Comparison of Three Different Sitting Positions for Performing Combined Spinal-Epidural Anesthesia N/A
Completed NCT04306133 - PENG Block Combined to Wound Infiltration for Hip Replacement N/A