Indocyanine green (ICG) is a water-soluble, non-toxic tricarbocyanine dye, extracted principally by hepatic parenchymal cells and excreted almost entirely into the bile without enterohepatic circulation. Clinically, its elimination rate is used primarily to measure hepatic function and liver blood flow. ICG studies are also used in ophthalmic angiography and the determination of cardiac output.

Beginning about 1959, the first human clinical studies were reported wherein an indocyanine green (ICG) bolus was injected into a vein, and then blood samples were withdrawn over a period of time and analyzed for ICG concentrations. This method is referred to hereinafter as the serial blood sampling method. These blood samples are sent to a clinical laboratory for a multi-step process of centrifuging, separation and spectrophotometric measurements of ICG levels. The laboratory-based measured levels of residual ICG levels are then used to determine the ICG clearance rate and R15 value or residual amount of dye remaining after 15 minutes, expressed as a percentage of the initial concentration.

As an alternative to the time- and labor-consuming serial blood sampling method, a non-invasive technique was first reported nearly 20 years ago. In the first published clinical study, Ishigami reported the use of a pulse dye densitometry (PDD) method to transcutaneously detect the rate of clearance of ICG from the bloodstream to be referred to hereinafter as dynamic liver function testing.

PDD expresses ICG elimination in terms of the indocyanine green plasma disappearance rate because only relative ICG concentration changes are assessed. The results of this noninvasive method have been shown to correlate with those obtained by the invasive method used in critically ill patients (hemodynamically unstable and stable), and in patients after liver surgery.

ICG elimination rate after liver transplantation measured by either invasive or noninvasive ICG methods is widely used to evaluate graft function. Studies have shown that ICG elimination, measured on the day of transplantation, reflects graft function and can be used to predict graft viability and the expected survival of the patient. Sequential measurements of ICG elimination between days 0 and 28 of transplantation, have been shown to predict clinical outcome in the early postoperative period after living donor transplantation. All of the studies have shown that the ICG elimination rate is an accurate test for evaluating liver dysfunction, but lacks the ability to differentiate the underlying causes of the hepatic dysfunction.

Unlike all currently existing PDD methods for performing liver function testing, LFT Dye Monitor System employs a more sensitive method for the transcutaneous measurement of ICG concentration level in the blood using NIR fluorescence, with a sensor that is attached loosely to the scaphoid fossa of the ear. Thus, the chemical properties of ICG dye to fluoresce when properly excited are used in the LFT system to enable much lower concentrations of ICG to be detectable. ;


Study Design

Allocation: Non-Randomized, Endpoint Classification: Safety/Efficacy Study, Intervention Model: Single Group Assignment, Masking: Open Label, Primary Purpose: Diagnostic


Related Conditions & MeSH terms


NCT number NCT02552901
Study type Interventional
Source Cardiox Corporation
Contact
Status Withdrawn
Phase Phase 3
Start date November 2015
Completion date May 2016

See also
  Status Clinical Trial Phase
Recruiting NCT03791190 - RCA for CRRT in Liver Failure and High Risk Bleeding Patients N/A
Recruiting NCT05989958 - The Safety and Tolerability Study of HepaCure in Chinese Subjects With Acute-On-Chronic Liver Failure Phase 1
Completed NCT02557724 - Mobilization of Mesenchymal Stem Cells During Liver Transplantation
Recruiting NCT01698723 - A Trial of Ribavirin in Patients With ACLF Due to Hepatitis E Virus Phase 2
Completed NCT01404793 - SPME For Metabolomics And Concomitant Measurements Of Rocuronium Bromide Levels In Liver Transplantation N/A
Completed NCT01425385 - Autoregulation Assessment During Liver Transplantation N/A
Completed NCT00808691 - Microcirculation and Oxidative Stress in Critical Ill Patients in Surgical Intensive Care Unit N/A
Completed NCT03864497 - Myocardial Perfusion Imaging in Liver Transplantation Candidates
Completed NCT00287235 - Efficacy of Albumin Dialysis to Treat Patients With Hepatic Encephalopathy Using The Molecular Adsorbent Recirculating System (MARS) N/A
Completed NCT03650920 - Hepatitis C Virus (HCV) Positive Liver Grafts in HCV Negative Recipients N/A
Recruiting NCT05517668 - Evaluation of the Efficacy of Fomepizole in the Treatment of Acetaminophen Overdose Phase 2
Recruiting NCT05726032 - Empagliflozin in Patients With Cirrhosis and Ascites Phase 2
Recruiting NCT04548596 - NOninVasive Intracranial prEssure From Transcranial doppLer Ultrasound Development of a Comprehensive Database of Multimodality Monitoring Signals for Brain-Injured Patients
Recruiting NCT02331745 - RCT Study on Granulocyte Colony-stimulating Factor(G-CSF) Treatment of Hepatic Failure Phase 4
Not yet recruiting NCT01961440 - Prognosis Scoring System for Acute-on-Chronic Liver Failure N/A
Active, not recruiting NCT01221454 - Allogenic Bone Marrow Stem Cell Transplantation in Liver Failure Phase 2
Completed NCT00772148 - Pharmacokinetics of LCP-Tacro™ Once Daily and Prograf® Twice A Day in Adult De Novo Liver Transplant Patients Phase 2
Completed NCT05592106 - Gd-EOB-DTPA-enhanced T1 Map for Predicting Postoperative Liver Failure
Not yet recruiting NCT06014320 - Alterations in Coagulation Factor Levels in Patients With End Stage Liver Disease
Recruiting NCT04221672 - The Effect of Terlipressin on Recovery of Liver Function After Hepatectomy Phase 3