Clinical Trials Logo

Clinical Trial Summary

Hemolysis during and after catheter ablation will be compared between catheter ablation performed using radiofrequency and pulsed-field energy. Consecutive patients indicated for catheter ablation for AF will be enrolled, catheter ablation will be done using standard catheters (Qdot, Biosense Webster for RF, and Farapulse, Boston-Scientific for PF). Blood samples will be drawn at the beginning of ablation (T1), at the end of ablation (T2), and one day after the procedure (T3). Hemolysis will be analyzed using flow cytometry, ELISA and standard biochemistry and compared between RF and PF patients, Primary hypothesis is that hemolysis level will be higher after PF ablation compared to RF ablation.


Clinical Trial Description

Catheter ablation presents the most effective treatment for atrial fibrillation (AF). It consists of the electrical isolation of the pulmonary veins. Several kinds of ablation energies can be used for the ablation. So far, the most often kind of energy was radiofrequency (RF) energy that leads to thermal destruction of the cardiac tissue. Newly, pulsed-field (PF) energy was developed for catheter ablation of AF. The use of PF energy consists in ultra-short, high-power application of electrical impulses that lead to fast, non-thermal cardiac tissue destruction. Despite significant advantages, such as tissue selectivity, short procedure duration, and high durability of ablated lesions, the use of PF energy could also have other adverse effects. Recently, renal failure due to accelerated peri-procedural hemolysis in patients with pre-existed renal disease was described after PF ablation for AF. The aim of the project is to assess and compare the level of hemolysis during catheter ablation for AF using PF and RF energy. Sixty consecutive patients indicated for catheter ablation for AF according to the standard recommendation (symptomatic paroxysmal or non-paroxysmal AF) will be enrolled. Consecutive patients as they are scheduler for procedure will be enrolled without randomization. In 40 patients (20 paroxysmal and 20 non-paroxysmal), the ablation will be done using PF energy, and in 20 patients using RF energy. In all patients, intracardiac echocardiography (Accunav, Siemens, Germany) and fluoroscopy will be used for navigation. The procedures will be done as it is currently routinely done in the EP lab. In RF patients, 4 vascular access will be used (one for 10-pole catheter placed into the coronary sinus, one for intracardiac echocardiography probe, and 2 for transseptal sheaths). Two transseptal punctures will be done under the guidance of intracardiac echocardiography using SL1 sheaths (Abbott, USA). One transseptal access will be used for diagnostic circular mapping catheter (Lasso, Biosense-Webster, USA), the other for the ablation catheter. The RF ablation will be performed using SmartTouch or QDot ablation catheters (both Biosense-Webster, USA); however, ablation will be driven by the ablation index even if QDot catheter is used. The RF ablation will be performed using ablation index (400-450 on anterior-superior aspects and 350-400 on posterior aspects of PVs), the QDot Plus (high-power short-duration) regimen won´t be used. The goal will be to achieve the entrance and exit block of all 4 PVs. In non-paroxysmal patients, additional ablations could be done at the discretion of the treating physician (fractionated singnals, lines). In the PF patients, two vascular access will be obtained. The first will be used for intracardiac echocardiography, the second for the transseptal sheath. Transseptal puncture will be done also using SL1 sheath (Abbott, USA), and using over-the-wire technique, this sheath will be exchanged by the 16-F Faradrive sheath (BSCI, USA). The ablation then will be done using pentaspline ablation catheter (Farawave, Boston Scientific). Four application of pulsed-field energy in basket configuration, and 4 application in flower configuration will be applied to each pulmonary vein. Additional pulsed-field energy application could be added if the signal in PV are present. In non-paroxysmal patients, additional pulsed-field energy application could be applied on the discretion of the operator on the posterior wall, or mitral isthmus. Blood samples will be taken at the beginning of the procedure from the femoral vein (T1), at the end of the procedure after ablation lesions completion (T2), and one day after the procedure (T3). Hemolysis will be assessed in all three samples 1) using flow cytometry (by means of measurement of "erythrocyte microparticles detected by the presence of antigens glycophorin A and Annexin V) and 2) using ELISA method (assessment of "cell free hemoglobin " concentration). Additionelly, standard biochemistry and blood count analysis will be done from the T1 and T3 samples (the concentration of lactate dehydrogenase, haptoglobin, indirect bilirubin, reticulocytes, and immature reticulocyte fraction). Primary hypothesis is that the level of hemolysis will be higher after PF ablation compared to RF ablation. Since no studies were published on the hemolysis either during RF or PF ablation, no reliable power calculation can be done. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT06096428
Study type Observational
Source Charles University, Czech Republic
Contact
Status Not yet recruiting
Phase
Start date November 15, 2023
Completion date March 30, 2024

See also
  Status Clinical Trial Phase
Recruiting NCT05654272 - Development of CIRC Technologies
Terminated NCT04115735 - His Bundle Recording From Subclavian Vein
Completed NCT04571385 - A Study Evaluating the Efficacy and Safety of AP30663 for Cardioversion in Participants With Atrial Fibrillation (AF) Phase 2
Completed NCT05366803 - Women's Health Initiative Silent Atrial Fibrillation Recording Study N/A
Completed NCT02864758 - Benefit-Risk Of Arterial THrombotic prEvention With Rivaroxaban for Atrial Fibrillation in France
Recruiting NCT05442203 - Electrocardiogram-based Artificial Intelligence-assisted Detection of Heart Disease N/A
Completed NCT05599308 - Evaluation of Blood Pressure Monitor With AFib Screening Feature N/A
Completed NCT03790917 - Assessment of Adherence to New Oral anTicoagulants in Atrial Fibrillation patiEnts Within the Outpatient registrY
Enrolling by invitation NCT05890274 - Atrial Fibrillation (AF) and Electrocardiogram (EKG) Interpretation Project ECHO N/A
Recruiting NCT05266144 - Atrial Fibrillation Patients Treated With Catheter Ablation
Recruiting NCT05316870 - Construction and Effect Evaluation of Anticoagulation Management Model in Atrial Fibrillation N/A
Not yet recruiting NCT06023784 - The Impact of LBBAP vs RVP on the Incidence of New-onset Atrial Fibrillation in Patients With Atrioventricular Block N/A
Recruiting NCT05572814 - Transform: Teaching, Technology, and Teams N/A
Recruiting NCT04092985 - Smart Watch iECG for the Detection of Cardiac Arrhythmias
Completed NCT04087122 - Evaluate the Efficiency Impact of Conducting Active Temperature Management During Cardiac Cryoablation Procedures N/A
Completed NCT06283654 - Relieving the Emergency Department by Using a 1-lead ECG Device for Atrial Fibrillation Patients After Pulmonary Vein Isolation
Recruiting NCT05416086 - iCLAS™ Cryoablation System Post-Market Clinical Follow-up (PMCF) Study N/A
Completed NCT05067114 - Solutions for Atrial Fibrillation Edvocacy (SAFE)
Completed NCT04546763 - Study Watch AF Detection At Home
Completed NCT03761394 - Pulsewatch: Smartwatch Monitoring for Atrial Fibrillation After Stroke N/A